Comparison of three distinct surgical clothing systems for protection from air-borne bacteria: A prospective observational study

BackgroundTo prevent surgical site infection it is desirable to keep bacterial counts low in the operating room air during orthopaedic surgery, especially prosthetic surgery. As the air-borne bacteria are mainly derived from the skin flora of the personnel present in the operating room a reduction could be achieved by using a clothing system for staff made from a material fulfilling the requirements in the standard EN 13795. The aim of this study was to compare the protective capacity between three clothing systems made of different materials – one mixed cotton/polyester and two polyesters - which all had passed the tests according to EN 13795.MethodsMeasuring of CFU/m3 air was performed during 21 orthopaedic procedures performed in four operating rooms with turbulent, mixing ventilation with air flows of 755 – 1,050 L/s. All staff in the operating room wore clothes made from the same material during each surgical procedure.ResultsThe source strength (mean value of CFU emitted from one person per second) calculated for the three garments were 4.1, 2.4 and 0.6 respectively. In an operating room with an air flow of 755 L/s both clothing systems made of polyester reduced the amount of CFU/m3 significantly compared to the clothing system made from mixed material. In an operating room with air intake of 1,050 L/s a significant reduction was only achieved with the polyester that had the lowest source strength.ConclusionsPolyester has a better protective capacity than cotton/polyester. There is need for more discriminating tests of the protective efficacy of textile materials intended to use for operating garment.

[1]  Gary R Seabrook,et al.  Molecular epidemiology of microbial contamination in the operating room environment: Is there a risk for infection? , 2005, Surgery.

[2]  Bengt Ljungqvist,et al.  Performance of clothing systems in the context of operating rooms; a question of patient safety. , 2011 .

[3]  J. Ojajärvi,et al.  The conventionally ventilated operating theatre and air contamination control during cardiac surgery--bacteriological and particulate matter control garment options for low level contamination. , 1998, European journal of cardio-thoracic surgery : official journal of the European Association for Cardio-thoracic Surgery.

[4]  J. Charnley,et al.  SECTION II GENERAL ORTHOPAEDICS Postoperative Infection after Total Hip Replacement with Special Reference to Air Contamination in the Operating Room , 1972, Clinical orthopaedics and related research.

[5]  E. Ståhle,et al.  Dispersal of methicillin-resistant Staphylococcus epidermidis by staff in an operating suite for thoracic and cardiovascular surgery: relation to skin carriage and clothing. , 2000, The Journal of hospital infection.

[6]  Ann Tammelin,et al.  Routes and Sources of Staphylococcus aureus Transmitted to the Surgical Wound During Cardiothoracic Surgery Possibility of Preventing Wound Contamination by Use of Special Scrub Suits , 2001, Infection Control & Hospital Epidemiology.

[7]  D. Hamblen,et al.  An investigation of occlusive polyester surgical clothing. , 1990, The Journal of hospital infection.

[8]  O M Lidwell,et al.  Air, antibiotics and sepsis in replacement joints. , 1988, The Journal of hospital infection.