Oxygen Optode Sensors: Principle, Characterization, Calibration, and Application in the Ocean

Recently, measurements of oxygen concentration in the ocean – one of the most classical parameters in chemical oceanography – are experiencing a revival. This is not surprising, given the key role of oxygen for assessing the status of the marine carbon cycle and feeling the pulse of the biological pump. The revival, however, has to a large extent been driven by the availability of robust optical oxygen sensors and their painstakingly thorough characterization. For autonomous observations, oxygen optodes are the sensors of choice: They are used abundantly on Biogeochemical-Argo floats, gliders and other autonomous oceanographic observation platforms. Still, data quality and accuracy are often suboptimal, in some part because sensor and data treatment are not always straightforward and/or sensor characteristics are not adequately taken into account. Here, we want to summarize the current knowledge about oxygen optodes, their working principle as well as their behaviour with respect to oxygen, temperature, hydrostatic pressure, and response time. The focus will lie on the most widely used and accepted optodes made by Aanderaa and Sea-Bird. We revisit the essentials and caveats of in-situ in air calibration as well as of time response correction for profiling applications, and provide requirements for a successful field deployment. In addition, all required steps to post-correct oxygen optode data will be discussed. We hope this summary will serve as a comprehensive, yet concise reference to help people get started with oxygen observations, ensure successful sensor deployments and acquisition of highest quality data, and facilitate post-treatment of oxygen data. In the end, we hope that this will lead to more and higher-quality oxygen observations and help to advance our understanding of ocean biogeochemistry in a changing ocean.

[1]  D. Nicholson,et al.  Air calibration of an oxygen optode on an underwater glider , 2017 .

[2]  Virginie Thierry,et al.  SCOR WG 142: Quality Control Procedures for Oxygen and Other Biogeochemical Sensors on Floats and Gliders. Recommendation for oxygen measurements from Argo floats, implementation of in-air-measurement routine to assure highest long-term accuracy , 2015 .

[3]  Virginie Thierry,et al.  SCOR WG 142: Quality Control Procedures for Oxygen and Other Biogeochemical Sensors on Floats and Gliders. Recommendations on the conversion between oxygen quantities for Bio-Argo floats and other autonomous sensor platforms , 2018 .

[4]  Dana D. Swift,et al.  Accurate oxygen measurements on modified Argo floats using in situ air calibrations , 2016 .

[5]  H. Kautsky,et al.  Quenching of luminescence by oxygen , 1939 .

[6]  S. Riser,et al.  A climatology‐based quality control procedure for profiling float oxygen data , 2013 .

[7]  H. Ludwig,et al.  The significance of the activity of dissolved oxygen, and other gases, enhanced by high hydrostatic pressure. , 2005, Comparative biochemistry and physiology. Part A, Molecular & integrative physiology.

[8]  S. Bushinsky,et al.  A method for in-situ calibration of Aanderaa oxygen sensors on surface moorings , 2013 .

[9]  S. Riser,et al.  Air Oxygen Calibration of Oxygen Optodes on a Profiling Float Array , 2015 .

[10]  E. D’Asaro,et al.  Calibration and Stability of Oxygen Sensors on Autonomous Floats , 2013 .

[11]  R. Weiss,et al.  Nitrous oxide solubility in water and seawater , 1980 .

[12]  John W. Kanwisher,et al.  Polarographic Oxygen Electrode1 , 1959 .

[13]  G. Johnson,et al.  CTD OXYGEN SENSOR CALIBRATION PROCEDURES , 2010 .

[14]  A. Körtzinger,et al.  Time response of oxygen optodes on profiling platforms and its dependence on flow speed and temperature , 2014 .

[15]  Stefan Sommer,et al.  Evaluation of a lifetime‐based optode to measure oxygen in aquatic systems , 2006 .

[16]  Henry C. Bittig,et al.  Pressure response of Aanderaa and Sea-Bird oxygen optodes , 2015 .

[17]  Louis I. Gordon,et al.  Oxygen solubility in seawater : better fitting equations , 1992 .

[18]  A. Körtzinger,et al.  Technical note: Update on response times, in-air measurements, and in situ drift for oxygen optodes on profiling platforms , 2017 .

[19]  Q. Gibson,et al.  The activity of dissolved oxygen at 1000 atm hydrostatic pressure , 1976 .

[20]  L. W. Winkler,et al.  Die Bestimmung des im Wasser gelösten Sauerstoffes , 1888 .

[21]  Samuel J. Oltmans,et al.  Development and Validation of a Time-Lag Correction for Vaisala Radiosonde Humidity Measurements , 2004 .

[22]  P. F. Scholander,et al.  EFFECT OF HYDROSTATIC PRESSURE ON GASES DISSOLVED IN WATER. , 1965, The Journal of physical chemistry.

[23]  Catherine Schmechtig,et al.  Processing Argo measurement timing information at the DAC level , 2017 .

[24]  Scott C. Doney,et al.  Adding Oxygen to Argo: Developing a Global in-situ Observatory for Ocean Deoxygenation and Biogeochemistry , 2010 .

[25]  E. D’Asaro,et al.  A calibration equation for oxygen optodes based on physical properties of the sensing foil , 2014 .

[26]  S. Riser,et al.  In situ phase-domain calibration of oxygen Optodes on profiling floats , 2016 .

[27]  A. Körtzinger,et al.  The Ocean Takes a Deep Breath , 2004, Science.

[28]  Ingo Klimant,et al.  Indicators for optical oxygen sensors , 2012, Bioanalytical reviews.

[29]  J. Kanwisher Polarographic Oxygen Electrode , 1999 .

[30]  Henry C. Bittig,et al.  A novel electrochemical calibration setup for oxygen sensors and its use for the stability assessment of Aanderaa optodes , 2012 .

[31]  C. Taylor,et al.  The effect of pressure upon the solubility of oxygen in water. Implications of the deviation from the ideal gas law upon measurements of fluorescence quenching. , 1978, Archives of biochemistry and biophysics.

[32]  Ingo Klimant,et al.  Fiber‐optic oxygen microsensors, a new tool in aquatic biology , 1995 .

[33]  Virginie Thierry,et al.  Processing Argo OXYGEN data at the DAC level , 2013 .

[34]  James H. Carpenter,et al.  THE ACCURACY OF THE WINKLER METHOD FOR DISSOLVED OXYGEN ANALYSIS1 , 1965 .

[35]  Henry C. Bittig,et al.  In Situ CO2 and O2 Measurements on a Profiling Float , 2013 .

[36]  A. Sterl,et al.  Fifteen years of ocean observations with the global Argo array , 2016 .

[37]  F. A. Richards Chapter 9: Oxygen in the Ocean , 1957 .

[38]  Stephen C. Riser,et al.  Biogeochemical sensor performance in the SOCCOM profiling float array , 2017 .

[39]  Arne Körtzinger,et al.  High Quality Oxygen Measurements from Profiling Floats: A Promising New Technique , 2005 .

[40]  Nicolas Gruber,et al.  Ocean deoxygenation in a warming world. , 2010, Annual review of marine science.

[41]  Masao Fukasawa,et al.  In Situ Calibration of Optode-Based Oxygen Sensors , 2008 .

[42]  Dana D. Swift,et al.  Net community production at Ocean Station Papa observed with nitrate and oxygen sensors on profiling floats , 2016 .