Development of a multichannel implantable connector

Further development of active implantable medical devices (AIMDs) coming along with higher channel counts and improved maintainability raises the requirements for implantable connectors in such systems. We developed a concept for an implantable multichannel connector. Contact pads manufactured by laser-structuring that are embedded into a silicone substrate serve as contact partners. Processing features specific to two laser technologies were exploited not only to cut the materials but also to 3D-shape the surfaces of the contact pads. First tests for the long-term behavior show stable contact and isolation properties during 6 weeks of soaking at elevated temperature.

[1]  P. E. K. Donaldson The craggs connector; a termination for cooper cable , 2006, Medical and Biological Engineering and Computing.

[2]  Thomas Stieglitz,et al.  ELECTRODE MATERIALS FOR RECORDING AND STIMULATION , 2004 .

[3]  P. Donaldson,et al.  Twenty years of neurological prosthesis-making. , 1987, Journal of biomedical engineering.

[4]  B. Smith,et al.  In-line lead connector for use with implanted neuroprosthesis , 1991, IEEE Transactions on Biomedical Engineering.

[5]  Kevin L. Kilgore,et al.  Twenty year experience with implanted neuroprostheses , 2009, 2009 Annual International Conference of the IEEE Engineering in Medicine and Biology Society.

[6]  John G. Webster,et al.  Medical Instrumentation: Application and Design , 1997 .

[7]  P. E. K. Donaldson The Role of Platinum Metals in Neurological Pro sthe se s PROGRESS IN BIOMEDICAL APPLICATIONS , 1987 .

[8]  Thomas Stieglitz,et al.  Parylene-coated metal tracks for neural electrode arrays - Fabrication approaches and improvements utilizing different laser systems , 2012, 2012 Annual International Conference of the IEEE Engineering in Medicine and Biology Society.

[9]  N. K. Myshkin,et al.  Electrical Contacts: Fundamentals, Applications and Technology , 2006 .

[10]  D N Rushton,et al.  A reconnectable multiway implantable connector. , 2002, Medical engineering & physics.

[11]  S. Timsit,et al.  Electrical contact resistance: properties of stationary interfaces , 1998, Electrical Contacts - 1998. Proceedings of the Forty-Fourth IEEE Holm Conference on Electrical Contacts (Cat. No.98CB36238).

[12]  Warren M Grill,et al.  Impedance characteristics of deep brain stimulation electrodes in vitro and in vivo , 2009, Journal of neural engineering.

[13]  G J Suaning,et al.  Fabrication of implantable microelectrode arrays by laser cutting of silicone rubber and platinum foil , 2005, Journal of neural engineering.

[14]  K. L. Kilgore,et al.  Structured sleeve for repair of implantable in-line connectors , 2006, Medical and Biological Engineering and Computing.