Three-dimensional simulation of ultrasound propagation through trabecular bone structures measured by synchrotron microtomography

Three-dimensional numerical simulations of ultrasound transmission were performed through 31 trabecular bone samples measured by synchrotron microtomography. The synchrotron microtomography provided high resolution 3D mappings of bone structures, which were used as the input geometry in the simulation software developed in our laboratory. While absorption (i.e. the absorption of ultrasound through dissipative mechanisms) was not taken into account in the algorithm, the simulations reproduced major phenomena observed in real through-transmission experiments in trabecular bone. The simulated attenuation (i.e. the decrease of the transmitted ultrasonic energy) varies linearly with frequency in the MHz frequency range. Both the speed of sound (SOS) and the slope of the normalized frequency-dependent attenuation (nBUA) increase with the bone volume fraction. Twenty-five out of the thirty-one samples exhibited negative velocity dispersion. One sample was rotated to align the main orientation of the trabecular structure with the direction of ultrasonic propagation, leading to the observation of a fast and a slow wave. Coupling numerical simulation with real bone architecture therefore provides a powerful tool to investigate the physics of ultrasound propagation in trabecular structures. As an illustration, comparison between results obtained on bone modelled either as a fluid or a solid structure suggested the major role of mode conversion of the incident acoustic wave to shear waves in bone to explain the large contribution of scattering to the overall attenuation.

[1]  C. Langton,et al.  The measurement of broadband ultrasonic attenuation in cancellous bone. , 1984, Engineering in medicine.

[2]  J. Williams Ultrasonic wave propagation in cancellous and cortical bone: prediction of some experimental results by Biot's theory. , 1992, The Journal of the Acoustical Society of America.

[3]  A M Schott,et al.  Do ultrasound measurements on the os calcis reflect more the bone microarchitecture than the bone mass?: a two-dimensional histomorphometric study. , 1995, Bone.

[4]  G. Breart,et al.  Ultrasonographic heel measurements to predict hip fracture in elderly women: the EPIDOS prospective study , 1996, The Lancet.

[5]  Robert W. Graves,et al.  Simulating seismic wave propagation in 3D elastic media using staggered-grid finite differences , 1996, Bulletin of the Seismological Society of America.

[6]  R. Strelitzki On the measurement of the velocity of ultrasound in the os calcis using short pulses , 1996 .

[7]  G Van der Perre,et al.  A comparison of time-domain and frequency-domain approaches to ultrasonic velocity measurement in trabecular bone. , 1996, Physics in medicine and biology.

[8]  G Berger,et al.  In vitro assessment of the relationship between acoustic properties and bone mass density of the calcaneus by comparison of ultrasound parametric imaging and quantitative computed tomography. , 1997, Bone.

[9]  A. Hosokawa,et al.  Ultrasonic wave propagation in bovine cancellous bone. , 1997, The Journal of the Acoustical Society of America.

[10]  A. Hosokawa,et al.  Acoustic anisotropy in bovine cancellous bone. , 1998, The Journal of the Acoustical Society of America.

[11]  P. Laugier,et al.  Velocity dispersion of acoustic waves in cancellous bone , 1998, IEEE Transactions on Ultrasonics, Ferroelectrics and Frequency Control.

[12]  P R White,et al.  Ultrasonic propagation in cancellous bone: a new stratified model. , 1999, Ultrasound in medicine & biology.

[13]  P Cloetens,et al.  A synchrotron radiation microtomography system for the analysis of trabecular bone samples. , 1999, Medical physics.

[14]  B Bianco,et al.  Computational methods for ultrasonic bone assessment. , 1999, Ultrasound in medicine & biology.

[15]  M. Bouxsein,et al.  Scattering of ultrasound in cancellous bone: predictions from a theoretical model. , 2000, Journal of biomechanics.

[16]  P. Laugier,et al.  Phase and group velocities of fast and slow compressional waves in trabecular bone. , 2000, The Journal of the Acoustical Society of America.

[17]  P. Laugier,et al.  In vitro measurement of the frequency-dependent attenuation in cancellous bone between 0.2 and 2 MHz. , 2000, The Journal of the Acoustical Society of America.

[18]  K. Wear,et al.  Anisotropy of ultrasonic backscatter and attenuation from human calcaneus: implications for relative roles of absorption and scattering in determining attenuation. , 2000, The Journal of the Acoustical Society of America.

[19]  K. Wear A stratified model to predict dispersion in trabecular bone , 2001, IEEE Transactions on Ultrasonics, Ferroelectrics and Frequency Control.

[20]  S. Boonen,et al.  Quantitative Ultrasound and Trabecular Architecture in the Human Calcaneus * , 2001, Journal of bone and mineral research : the official journal of the American Society for Bone and Mineral Research.

[21]  K. Wear Ultrasonic attenuation in human calcaneus from 0.2 to 1.7 MHz , 2001, IEEE Transactions on Ultrasonics, Ferroelectrics and Frequency Control.

[22]  P. Laugier,et al.  Prediction of ultrasound attenuation in cancellous bones using poroelasticity and scattering theories , 2001, 2001 IEEE Ultrasonics Symposium. Proceedings. An International Symposium (Cat. No.01CH37263).

[23]  C. Tsogka,et al.  Application of the perfectly matched absorbing layer model to the linear elastodynamic problem in anisotropic heterogeneous media , 2001 .

[24]  F Peyrin,et al.  Ultrasonic characterization of human cancellous bone using transmission and backscatter measurements: relationships to density and microstructure. , 2002, Bone.

[25]  M. Kaczmarek,et al.  Short ultrasonic waves in cancellous bone. , 2002, Ultrasonics.

[26]  Pascal Laugier,et al.  Prediction of frequency-dependent ultrasonic backscatter in cancellous bone using statistical weak scattering model. , 2003, Ultrasound in medicine & biology.

[27]  F. Peyrin,et al.  Prediction of backscatter coefficient in trabecular bones using a numerical model of three-dimensional microstructure. , 2003, The Journal of the Acoustical Society of America.

[28]  Gangming Luo,et al.  On the relative contributions of absorption and scattering to ultrasound attenuation in trabecular bone: a simulation study , 2003, IEEE Symposium on Ultrasonics, 2003.

[29]  S. Goldstein,et al.  Three quantitative ultrasound parameters reflect bone structure , 1994, Calcified Tissue International.

[30]  F. Padilla,et al.  In Vitro Ultrasound Measurement at the Human Femur , 2004, Calcified Tissue International.

[31]  [Practical proposals for the use of quantitative bone ultrasound in the management of osteoporosis]. , 2004, Revue medicale de la Suisse romande.

[32]  Robert Luben,et al.  Prediction of total and hip fracture risk in men and women by quantitative ultrasound of the calcaneus: EPIC-Norfolk prospective population study , 2004, The Lancet.

[33]  Maryline Talmant,et al.  Three-dimensional simulations of ultrasonic axial transmission velocity measurement on cortical bone models. , 2004, The Journal of the Acoustical Society of America.

[34]  W. Lauriks,et al.  Ultrasonic wave propagation in human cancellous bone: application of Biot theory. , 2004, The Journal of the Acoustical Society of America.

[35]  P. Laugier,et al.  Assessment of the relationship between broadband ultrasound attenuation and bone mineral density at the calcaneus using BUA imaging and DXA , 2005, Osteoporosis International.

[36]  P. Christel,et al.  The effects of remodeling on the elastic properties of bone , 2006, Calcified Tissue International.