Reducing Motion Artifacts and Interference in Biopotential Recording

The application of engineering principles and techniques to biopotential recording has resulted in a continual improvement both in the type and the quality of recorded signals. Physical placement of electrodes has enabled improved discrimination of the biopotential of interest (such as the ECG) from unwanted biopotentials (such as the EMG). Understanding that the major motion artifact in ECG recording arises from the skin and not the electrode has resulted in techniques that reduce this artifact, such as skin abrasion and mechanical stabilization. However, skin abrasion makes the skin more subject to irritation, so mild gels are required. The development of the floating silver/silver chloride electrode has eliminated motion artifact and noise caused by the electrode. The development of the driven-right-leg circuit has greatly reduced interference due to power lines. Adaptive filters have reduced the difficult-to-eliminate interference due to spark-gap electrosurgical units.

[1]  R. E. Mason,et al.  A new system of multiple-lead exercise electrocardiography. , 1966, American heart journal.

[2]  A K Dobbie The electrical aspects of surgical diathermy. , 1969, Biomedical engineering.

[3]  D. H. Vandercar,et al.  Lightweight FET circuit for differential or single-ended recording in free-moving animals. , 1972, Physiology & behavior.

[4]  J A Klijn,et al.  Cable artefact suppressor for electrophysiological recording. , 1973, Electromyography and clinical neurophysiology.

[5]  J G Webster,et al.  60-HZ interference in electrocardiography. , 1973, IEEE transactions on bio-medical engineering.

[6]  Noise‐Free Electrocardiographic Data During Electrosurgical Procedures , 1973, Anesthesia and analgesia.

[7]  J A Klijn,et al.  Movement artefact suppressor during ECG monitoring. , 1974, Cardiovascular research.

[8]  David H. Gordon,et al.  Triboelectric Interference in the ECG , 1975, IEEE Transactions on Biomedical Engineering.

[9]  J. Webster,et al.  Minimizing Electrode Motion Artifact by Skin Abrasion , 1977, IEEE Transactions on Biomedical Engineering.

[10]  Nitish V. Thakor,et al.  Ground-Free ECG Recording with Two Electrodes , 1980, IEEE Transactions on Biomedical Engineering.

[11]  John M. Cioffi,et al.  ECG Enhancement by Adaptive Cancellation of Electrosurgical Interference , 1983, IEEE Transactions on Biomedical Engineering.

[12]  John G. Webster,et al.  Driven-right-leg circuit design , 1983, IEEE Transactions on Biomedical Engineering.