Design and optimization of a hip disarticulation prosthesis using the remote center of motion mechanism.

BACKGROUND Hip disarticulation prostheses (HDPs) are not routinely seen in clinical practice, and traditional hip prostheses rotate around an axis at the front side of the pelvic socket. OBJECTIVE This study proposes a mechanism to restore the rotation center to the acetabulum of the amputated side and uses comparative experiments with traditional HDP to verify the validity of the novel design. METHODS A double parallelogram design of HDP based on a remote center of motion (RCM) mechanism was presented in this paper. Optimization was achieved by a genetic algorithm with the maximal integral size and minimal driving force of the mechanism. RESULTS The prototype was developed by final optimal results and tested by a hip disarticulated amputee. Testing results revealed that the RCM-HDP improved the range of motion of the hip prosthesis by 78%. The maximal flexion of the assorted prosthetic knee was closer to the sound side than a traditional HDP by 15%. CONCLUSION The proposed RCM-HDP promoted the kinematic performance and symmetry of the hip prosthesis compared to the traditional design.

[1]  Long Wang,et al.  Locomotion Mode Classification Using a Wearable Capacitive Sensing System , 2013, IEEE Transactions on Neural Systems and Rehabilitation Engineering.

[2]  T. Akisue,et al.  Successful First Gait of a Child With Hip-Disarticulation Prosthesis. , 2018, American journal of physical medicine & rehabilitation.

[3]  Gerald Stark Overview of Hip Disarticulation Prostheses , 2001 .

[4]  Qining Wang,et al.  Combining Push-Off Power and Nonlinear Damping Behaviors for a Lightweight Motor-Driven Transtibial Prosthesis , 2017, IEEE/ASME Transactions on Mechatronics.

[5]  Leif M Nelson,et al.  Functional Outcome Measurements of a Veteran With a Hip Disarticulation Using a Helix 3D Hip Joint: A Case Report , 2011 .

[6]  A. Till,et al.  Rehabilitation of patients after hip disarticulation , 1997, Archives of Orthopaedic and Trauma Surgery.

[7]  W D Spence,et al.  Reciprocating gait prosthesis for the bilateral hip disarticulation amputee , 2001, Proceedings of the Institution of Mechanical Engineers. Part H, Journal of engineering in medicine.

[8]  Chee-Meng Chew,et al.  Virtual Model Control: An Intuitive Approach for Bipedal Locomotion , 2001, Int. J. Robotics Res..

[9]  T. Schmalz,et al.  Biomechanical Differences between Two Exoprosthetic Hip Joint Systems during Level Walking , 2010, Prosthetics and orthotics international.

[10]  Fumitoshi Matsuno,et al.  Design and optimization of a 2-degree-of-freedom planar remote center of motion mechanism for surgical manipulators with smaller footprint , 2018, Mechanism and Machine Theory.

[11]  S Sawamura,et al.  Energy expenditure during walking in amputees after disarticulation of the hip. A microprocessor-controlled swing-phase control knee versus a mechanical-controlled stance-phase control knee. , 2005, The Journal of bone and joint surgery. British volume.

[12]  Barri L Schnall,et al.  Gait Characteristics of a Soldier With a Traumatic Hip Disarticulation , 2008, Physical Therapy.

[13]  Xiaofei Wang,et al.  Optimization of a novel mechanism for a minimally invasive surgery robot , 2010, The international journal of medical robotics + computer assisted surgery : MRCAS.

[14]  Desarticulação da anca - Análise de uma série e revisão da literatura , 2017 .

[15]  Simon Christensen,et al.  Kinematic Analysis and Design of a Novel Shoulder Exoskeleton Using a Double Parallelogram Linkage , 2018, Journal of Mechanisms and Robotics.

[16]  Sébastien Briot,et al.  Topology optimization of industrial robots: Application to a five-bar mechanism , 2018 .

[17]  Energy Consumption During Prosthetic Walking and Wheelchair Locomotion by Elderly Hip Disarticulation Amputees , 2009, American journal of physical medicine & rehabilitation.