FDG-PET imaging of lower extremity muscular activity during level walking

Abstract. We analyzed muscular activity of the lower extremities during level walking using positron emission tomography (PET) with 18F-fluorodeoxyglucose (18F-FDG). We examined 17 healthy male subjects; 11 were assigned to a walking group and 6 to a resting group. After 18F-FDG injection, the walking group subjects walked at a free speed for 15 min. A whole-body image was then obtained by a PET camera, and the standardized uptake ratio (SUR) was computed for each muscle. The SUR for each muscle of the walking group was compared with that for the corresponding muscles in the resting group. The level of muscular activity of all the muscles we examined were higher during level walking than when resting. The activity of the lower leg muscles was higher than that of the thigh muscles during level walking. The muscular activity of the soleus was highest among all the muscles examined. Among the gluteal muscles, the muscular activity of the gluteus minimus was higher than that of the gluteus maximus and gluteus medius. The concurrent validity of measuring muscular activity of the lower extremity during level walking by the PET method using 18F-FDG was demonstrated.

[1]  M. Tashiro,et al.  Whole-body metabolic map with positron emission tomography of a man after running , 1996, The Lancet.

[2]  D. Sutherland,et al.  An electromyographic study of the plantar flexors of the ankle in normal walking on the level. , 1966, The Journal of bone and joint surgery. American volume.

[3]  N Shiba,et al.  Functional evaluation of hip abductor muscles with use of magnetic resonance imaging , 1997, Journal of orthopaedic research : official publication of the Orthopaedic Research Society.

[4]  D A Winter,et al.  Electromyographic temporal analysis of gait: normal human locomotion. , 1976, Archives of physical medicine and rehabilitation.

[5]  M. Tashiro,et al.  Glucose uptake by individual skeletal muscles during running using whole-body positron emission tomography , 2000, European Journal of Applied Physiology.

[6]  J. Ekholm,et al.  Quantified electromyography of lower-limb muscles during level walking. , 2020, Scandinavian journal of rehabilitation medicine.

[7]  M. Permutt,et al.  Glucose transporter protein content and glucose transport capacity in rat skeletal muscles. , 1990, The American journal of physiology.

[8]  M. Tashiro,et al.  18F-FDG PET imaging of muscle activity in runners. , 1999, Journal of nuclear medicine : official publication, Society of Nuclear Medicine.

[9]  P. Thompson,et al.  ACSM's Guidelines for Exercise Testing and Prescription , 1995 .

[10]  M. Reivich,et al.  THE [14C]DEOXYGLUCOSE METHOD FOR THE MEASUREMENT OF LOCAL CEREBRAL GLUCOSE UTILIZATION: THEORY, PROCEDURE, AND NORMAL VALUES IN THE CONSCIOUS AND ANESTHETIZED ALBINO RAT 1 , 1977, Journal of neurochemistry.

[11]  D. Winter Energy generation and absorption at the ankle and knee during fast, natural, and slow cadences. , 1983, Clinical orthopaedics and related research.

[12]  N. Otsu A threshold selection method from gray level histograms , 1979 .

[13]  E. Hoffman,et al.  Tomographic measurement of local cerebral glucose metabolic rate in humans with (F‐18)2‐fluoro‐2‐deoxy‐D‐glucose: Validation of method , 1979, Annals of neurology.

[14]  JoAnne K. Gronley,et al.  Timing and relative intensity of hip extensor and abductor muscle action during level and stair ambulation. An EMG study. , 1983, Physical therapy.

[15]  M. Johnson,et al.  Data on the distribution of fibre types in thirty-six human muscles. An autopsy study. , 1973, Journal of the neurological sciences.

[16]  S Yoshioka,et al.  Lung tumor imaging by positron emission tomography using C-11 L-methionine. , 1985, Journal of nuclear medicine : official publication, Society of Nuclear Medicine.