Conductometric determination of ammonium ion with a mobile drop.

A mobile drop based approach was utilized for the conductometric determination of aqueous ammonium ion. A liquid drop was manipulated by gravity to remain or move out of a conductivity measurement zone located on a hydrophobic path. A dilute sulfuric acid drop functioned as a micro gas absorber. Gaseous NH3 was liberated from a sample containing NH4(+) by adding NaOH and purged to flow over the absorber drop. As H(+) in the absorber drop was converted to NH4(+), the conductivity decreased. The rate of the conductivity decrease thus ultimately depended on the NH4(+) concentration in the sample. While the sample could be complex, the liberation of NH3 gas essentially freed the analyte of interest from the matrix and allowed the use of an otherwise nonselective detector. The system was applied to the determination of NH4(+) in some natural waters without prior filtration; the results agreed well with those from a manual indophenol blue method. The approach exhibited a limit of detection (LOD) of 5 μM and a relative standard deviation (RSD) of<5%. The mobile drop gave a constant volume of the gas absorbing solution and provided a cost-effective and simple analytical platform.

[1]  R. Cattrall,et al.  Thin layer distillation for matrix isolation in flow analysis. , 2007, Talanta.

[2]  L. Clementson,et al.  Flow-injection analysis with fluorescence detection for the determination of trace levels of ammonium in seawater. , 2005, Journal of environmental monitoring : JEM.

[3]  D. Nacapricha,et al.  Membraneless vaporization unit for direct analysis of solid sample. , 2007, Analytica chimica acta.

[4]  K. Toda,et al.  Measurement of ammonia in human breath with a liquid-film conductivity sensor. , 2006, Analytical chemistry.

[5]  A. Cardoso,et al.  Analytical chemistry in a liquid film/droplet , 1995 .

[6]  D. Nacapricha,et al.  A reagent-free SIA module for monitoring of sugar, color and dissolved CO2 content in soft drinks. , 2010, Analytica chimica acta.

[7]  Ildikó V. Tóth,et al.  A multi-commuted flow injection system with a multi-channel propulsion unit placed before detection: Spectrophotometric determination of ammonium. , 2007, Analytica chimica acta.

[8]  A. Cardoso,et al.  Fluorometric fiber optic drop sensor for atmospheric hydrogen sulfide. , 1997, Talanta.

[9]  K. Toda,et al.  On-site measurement of trace-level sulfide in natural waters by vapor generation and microchannel collection. , 2011, Environmental science & technology.

[10]  P. Dasgupta,et al.  Analytical chemistry in a drop , 1996 .

[11]  W. L. Borst,et al.  Soap bubbles in analytical chemistry. Conductometric determination of sub-parts per million levels of sulfur dioxide with a soap bubble. , 2006, Analytical chemistry.

[12]  B Haghighi,et al.  Sequential flow injection analysis of ammonium and nitrate using gas phase molecular absorption spectrometry. , 2004, Talanta.

[13]  Ildikó V. Tóth,et al.  Determination of ammonium in marine waters using a gas diffusion multicommuted flow injection system with in-line prevention of metal hydroxides precipitation. , 2009, Journal of environmental monitoring : JEM.

[14]  K. Grudpan,et al.  Doped soap membranes selectively permeate a chiral isomer. , 2010, Journal of the American Chemical Society.

[15]  W. Frenzel Gas-diffusion separation and flow injection potentiometry , 1990 .

[16]  S. Ohira,et al.  A simple inexpensive gas phase chemiluminescence analyzer for measuring trace levels of arsenic in drinking water. , 2010, Environmental pollution.

[17]  P. Dasgupta,et al.  Measurement of Gases by a Suppressed Conductometric Capillary Electrophoresis Separation System , 1995 .

[18]  M. Almendral-Parra,et al.  A Gas Diffusion Technique Coupled with Flow Injection Systems. Optimization of the Process in its Application to the Fluorimetric Determination of Ammonium in Water Samples , 2009, Journal of Fluorescence.

[19]  C. Y. Liu,et al.  Potentiometric and conductometric determination of ammonium by gas-diffusion flow injection analysis , 1992 .

[20]  P. K. Dasgupta,et al.  A membraneless gas diffusion unit: design and its application to determination of ethanol in liquors by spectrophotometric flow injection. , 2006, Analytica chimica acta.

[21]  Orawon Chailapakul,et al.  Amperometric Determination of Sulfite by Gas Diffusion-Sequential Injection with Boron-Doped Diamond Electrode , 2008, Sensors.

[22]  G. Boss,et al.  A disposable blood cyanide sensor. , 2013, Analytica chimica acta.

[23]  P. Dasgupta,et al.  Measurement of phenols on a loop-supported liquid film by micellar electrokinetic chromatography and direct UV detection. , 1996, Journal of chromatography. A.

[24]  M. Segundo,et al.  A membraneless gas-diffusion unit-multisyringe flow injection spectrophotometric method for ammonium determination in untreated environmental samples. , 2011, Talanta.

[25]  K. Grudpan,et al.  Micro coulometric titration in a liquid drop. , 2013, Talanta.

[26]  A. Cardoso,et al.  Construction and performance of a drop cell for the nephelometric determination of sulfur dioxide , 2003 .

[27]  Purnendu K. Dasgupta,et al.  Liquid Droplet. A Renewable Gas Sampling Interface , 1995 .

[28]  A. O. Rangel,et al.  Development of a sequential injection gas diffusion system for the determination of ammonium in transitional and coastal waters , 2011 .

[29]  D. Nacapricha,et al.  New membraneless vaporization unit coupled with flow systems for analysis of ethanol. , 2013, Analytica chimica acta.

[30]  M. Oshima,et al.  Highly sensitive determination method for total carbonate in water samples by flow injection analysis coupled with gas-diffusion separation. , 2001, Analytical sciences : the international journal of the Japan Society for Analytical Chemistry.

[31]  J. Jakmunee,et al.  Flow injection conductometric system with gas diffusion separation for the determination of Kjeldahl nitrogen in milk and chicken meat. , 2008, Analytica chimica acta.

[32]  J. A. Silva,et al.  Trace Levels Determination of Ammonium by Flow Injection Analysis Using Gas-Diffusion and Capacitively Coupled Contactless Conductivity Detection , 2011 .

[33]  R. Cattrall,et al.  Determination of ammonia in wastewaters containing high concentrations of surfactants by flow injection potentiometry with on-line sample clean-up , 1998 .