Fungal spore transport through a building structure.

The study carried out laboratory measurements with a full-scale timber frame structure to determine penetration of inert particles with size distribution from 0.6 to 4 microm and spores of Penicillium and Cladosporium through the structure. Pressure difference over and air leakage through the structure were varied. Measurements at moderate pressure differences resulted in the penetration factors within the range of 0.05-0.2 for inert particles, and indicated also the penetration of fungal spores through the structure. The measurements showed that the penetration was highly dependent on pressure difference over the structure but not on holes in surface boards of the structure. The results show that surface contacts between the frames and mineral wool may have a significant effect on penetration. The penetration was approximately constant within particle size rage of 0.6-2.5 microm, but particles with diameter of 4.0 microm did not penetrate through the structure at all even at a higher-pressure difference of 20 Pa, except in the case of direct flow-path through the structure. Results have important consequences for practical design showing that penetration of fungal spores through the building envelope is difficult to prevent by sealing. The only effective way to prevent penetration seems to be balancing or pressurizing the building. In cold climates, moisture condensation risk should be taken into account if pressure is higher indoors than outdoors. Determined penetration factors were highly dependent on the pressure difference. Mechanical exhaust ventilation needs a special consideration as de-pressurizing the building may cause health risk if there is hazardous contamination in the building envelope exists.

[1]  P J Catalano,et al.  Using time- and size-resolved particulate data to quantify indoor penetration and deposition behavior. , 2001, Environmental science & technology.

[2]  Tiina Reponen,et al.  Aerodynamic Diameters and Respiratory Deposition Estimates of Viable Fungal Particles in Mold Problem Dwellings , 1995 .

[3]  L. E. Sparks,et al.  Penetration of Ambient Fine Particles into the Indoor Environment , 2001 .

[4]  Tiina Reponen,et al.  The indoor air quality in finnish homes with mold problems , 1991 .

[5]  M Airaksinen,et al.  Microbial contamination of indoor air due to leakages from crawl space: a field study. , 2004, Indoor air.

[6]  W. Fisk,et al.  Performance and costs of particle air filtration technologies. , 2002, Indoor air.

[7]  John H. Seinfeld,et al.  Turbulent deposition and gravitational sedimentation of an aerosol in a vessel of arbitrary shape , 1981 .

[8]  J Schwartz,et al.  Confounding and Effect Modification in the Short-Term Effects of Ambient Particles on Total Mortality: Results from 29 European Cities within the APHEA2 Project , 2001, Epidemiology.

[9]  J. Schwartz,et al.  The National Morbidity, Mortality, and Air Pollution Study. Part II: Morbidity and mortality from air pollution in the United States. , 2000, Research report.

[10]  P. Lawless,et al.  Characterization of Indoor-Outdoor Aerosol Concentration Relationships during the Fresno PM Exposure Studies , 2001 .

[11]  Paul J. Catalano,et al.  Relative contribution of outdoor and indoor particle sources to indoor concentrations , 2000 .

[12]  J Pekkanen,et al.  Fine particulate air pollution, resuspended road dust and respiratory health among symptomatic children. , 1999, The European respiratory journal.

[13]  Yung-sung Cheng Wall Deposition of Radon Progeny and Particles in a Spherical Chamber , 1997 .

[14]  Alvin C.K. Lai,et al.  Particle deposition indoors: a review , 2002 .

[15]  A. Lai Particle deposition indoors: a review. , 2002, Indoor air.

[16]  Anne Hyvärinen,et al.  Prevalence of moisture problems in Finnish houses , 1998 .

[17]  B. Flannigan,et al.  Mould in buildings: the air spora of domestic dwellings , 1988 .

[18]  Tiina Reponen,et al.  Normal Range Criteria for Indoor Air Bacteria and Fungal Spores in a Subarctic Climate , 1992 .

[19]  Y. Kuo,et al.  Seasonal fungus prevalence inside and outside of domestic environments in the subtropical climate , 1994 .

[20]  M. Beneš,et al.  Aerosol wall deposition in enclosures investigated by means of a stagnant layer , 1996 .

[21]  Y. Nomura,et al.  Deposition of Particles in a Chamber as a Function of Ventilation Rate , 1997 .

[22]  A A ANDERSEN,et al.  NEW SAMPLER FOR THE COLLECTION, SIZING, AND ENUMERATION OF VIABLE AIRBORNE PARTICLES, , 1958, Journal of bacteriology.

[23]  F. Allard,et al.  Indoor particle pollution: effect of wall textures on particle deposition , 2000 .

[24]  De-Ling Liu,et al.  Modeling pollutant penetration across building envelopes , 2001 .

[25]  J M Macher,et al.  A two-year study of microbiological indoor air quality in a new apartment. , 1991, Archives of environmental health.

[26]  Antony J. H. Goddard,et al.  Size specific indoor aerosol deposition measurements and derived I/O concentrations ratios , 1997 .

[27]  Y. Kuo,et al.  Characteristics of airborne microfungi in subtropical homes. , 1994, The Science of the total environment.

[28]  Antony J. H. Goddard,et al.  Experimental Studies of the Effect of Rough Surfaces and Air Speed on Aerosol Deposition in a Test Chamber , 2002 .

[29]  J. Schwartz,et al.  Association of fine particulate matter from different sources with daily mortality in six U.S. cities. , 2000, Environmental health perspectives.

[30]  P. Thorne,et al.  Bioaerosol Concentrations in Noncomplaint, Complaint, and Intervention Homes in the Midwest , 1995 .

[31]  Tracy L. Thatcher,et al.  Effects of room furnishings and air speed on particle deposition rates indoors , 2002 .

[32]  A. Verhoeff,et al.  Health risk assessment of fungi in home environments. , 1997, Annals of allergy, asthma & immunology : official publication of the American College of Allergy, Asthma, & Immunology.

[33]  Liisa Pirjola,et al.  Indoor air aerosol model: the effect of outdoor air, filtration and ventilation on indoor concentrations , 1999 .

[34]  Alvin C.K. Lai,et al.  Modeling Indoor Particle Deposition from Turbulent Flow onto Smooth Surfaces , 2000 .

[35]  A. Hyvärinen Characterizing moisture damaged buildings : Environmental and biological monitoring , 2002 .

[36]  R. Sextro,et al.  Deposition of Tobacco Smoke Particles in a Low Ventilation Room , 1994 .

[37]  William W. Nazaroff,et al.  Particle Penetration Through Building Cracks , 2003 .

[38]  Jarek Kurnitski Crawl space air change, heat and moisture behaviour , 2000 .

[39]  J. Peat,et al.  Effects of damp and mould in the home on respiratory health: a review of the literature , 1998, Allergy.