Orientation‐independent diffusion imaging without tensor diagonalization: Anisotropy definitions based on physical attributes of the diffusion ellipsoid

Diffusion tensor imaging can provide a complete description of the diffusion process in tissue. However, this description is not unique but is orientation dependent, and, to quantify properly the intrinsic orientation‐independent diffusion properties of the tissue, a set of three rotationally invariant quantities is needed. Instead of using the tensor eigenvalues for this, we define a new set consisting of scaled invariants that have the proper magnitude of actual diffusion constants and that are directly related to the physical attributes of the diffusion ellipsoid, namely, its average radius, surface, and volume. Using these three physical invariants, a new family of anisotropy measures is defined that are normalized between zero (isotropic) and one (completely anisotropic). Because rotational invariants are used, this approach does not require tensor diagonalization and eigenvalue determination and is therefore not susceptible to potential artifacts induced during these number manipulations. The relationship between the new anisotropy definitions and existing orientation‐independent anisotropy indices obtained from eigenvalues is discussed, after which the new approach is evaluated for a group of healthy volunteers. J. Magn. Reson. Imaging 1999;9:804–813. © 1999 Wiley‐Liss, Inc.

[1]  John Crank,et al.  The Mathematics Of Diffusion , 1956 .

[2]  E. Stejskal Use of Spin Echoes in a Pulsed Magnetic‐Field Gradient to Study Anisotropic, Restricted Diffusion and Flow , 1965 .

[3]  J. E. Tanner,et al.  Spin diffusion measurements : spin echoes in the presence of a time-dependent field gradient , 1965 .

[4]  P. R. Bevington,et al.  Data Reduction and Error Analysis for the Physical Sciences , 1969 .

[5]  J R Hansen,et al.  Pulsed NMR study of water mobility in muscle and brain tissue. , 1971, Biochimica et biophysica acta.

[6]  A. C. Young,et al.  Restricted diffusion in biophysical systems. Experiment. , 1974, Biophysical journal.

[7]  C F Hazlewood,et al.  Nuclear magnetic resonance measurement of skeletal muscle: anisotrophy of the diffusion coefficient of the intracellular water. , 1976, Biophysical journal.

[8]  J. E. Tanner,et al.  Self diffusion of water in frog muscle. , 1979, Biophysical journal.

[9]  H. Saunders,et al.  Book Reviews : Fracture and Fatigue Control in Structures - Application of Fracture Mechanics: S.T. Rolfe and J.M. Barsom Prentice-Hall, Inc., Englewood Cliffs, NJ, 1977 , 1979 .

[10]  P. Grenier,et al.  MR imaging of intravoxel incoherent motions: application to diffusion and perfusion in neurologic disorders. , 1986, Radiology.

[11]  Jörg Kärger,et al.  Principles and Application of Self-Diffusion Measurements by Nuclear Magnetic Resonance , 1988 .

[12]  J. Tsuruda,et al.  Diffusion-weighted MR imaging of anisotropic water diffusion in cat central nervous system. , 1990, Radiology.

[13]  D Le Bihan,et al.  Measuring random microscopic motion of water in tissues with MR imaging: a cat brain study. , 1991, Journal of computer assisted tomography.

[14]  P van Gelderen,et al.  Restricted and anisotropic displacement of water in healthy cat brain and in stroke studied by NMR diffusion imaging , 1991, Magnetic resonance in medicine.

[15]  P. Basser,et al.  MR diffusion tensor spectroscopy and imaging. , 1994, Biophysical journal.

[16]  P. V. van Zijl,et al.  Evaluation of restricted diffusion in cylinders. Phosphocreatine in rabbit leg muscle. , 1994, Journal of magnetic resonance. Series B.

[17]  P van Gelderen,et al.  Water diffusion and acute stroke , 1994, Magnetic resonance in medicine.

[18]  M. Bronskill,et al.  Anisotropy of NMR properties of tissues , 1994, Magnetic resonance in medicine.

[19]  Yihong Yang,et al.  Measurement of Water Diffusion in Hormone‐Treated Rat Uteri by Diffusion‐Weighted Magnetic Resonance Imaging , 1995, Magnetic resonance in medicine.

[20]  R. Dinsmore,et al.  Imaging myocardial fiber architecture in vivo with magnetic resonance , 1995, Magnetic resonance in medicine.

[21]  T E Conturo,et al.  Diffusion MRI: Precision, accuracy and flow effects , 1995, NMR in biomedicine.

[22]  P. Basser Inferring microstructural features and the physiological state of tissues from diffusion‐weighted images , 1995, NMR in biomedicine.

[23]  C. Decanniere,et al.  Correlation of rapid changes in the average water diffusion constant and the concentrations of lactate and ATP breakdown products during global ischemia in cat brain , 1995, Magnetic resonance in medicine.

[24]  P. V. van Zijl,et al.  Diffusion Weighting by the Trace of the Diffusion Tensor within a Single Scan , 1995, Magnetic resonance in medicine.

[25]  P. Basser,et al.  Toward a quantitative assessment of diffusion anisotropy , 1996, Magnetic resonance in medicine.

[26]  P. Basser,et al.  Diffusion tensor MR imaging of the human brain. , 1996, Radiology.

[27]  P. V. van Zijl,et al.  Correlation of the Average Water Diffusion Constant with Cerebral Blood Flow and Ischemic Damage after Transient Middle Cerebral Artery Occlusion in Cats , 1996, Journal of cerebral blood flow and metabolism : official journal of the International Society of Cerebral Blood Flow and Metabolism.

[28]  R N Bryan,et al.  Absolute quantitation of diffusion constants in human stroke. , 1997, Stroke.