Registration of phase‐contrast images in propagation‐based X‐ray phase tomography

X‐ray phase tomography aims at reconstructing the 3D electron density distribution of an object. It offers enhanced sensitivity compared to attenuation‐based X‐ray absorption tomography. In propagation‐based methods, phase contrast is achieved by letting the beam propagate after interaction with the object. The phase shift is then retrieved at each projection angle, and subsequently used in tomographic reconstruction to obtain the refractive index decrement distribution, which is proportional to the electron density. Accurate phase retrieval is achieved by combining images at different propagation distances. For reconstructions of good quality, the phase‐contrast images recorded at different distances need to be accurately aligned. In this work, we characterise the artefacts related to misalignment of the phase‐contrast images, and investigate the use of different registration algorithms for aligning in‐line phase‐contrast images. The characterisation of artefacts is done by a simulation study and comparison with experimental data. Loss in resolution due to vibrations is found to be comparable to attenuation‐based computed tomography. Further, it is shown that registration of phase‐contrast images is nontrivial due to the difference in contrast between the different images, and the often periodical artefacts present in the phase‐contrast images if multilayer X‐ray optics are used. To address this, we compared two registration algorithms for aligning phase‐contrast images acquired by magnified X‐ray nanotomography: one based on cross‐correlation and one based on mutual information. We found that the mutual information‐based registration algorithm was more robust than a correlation‐based method.

[1]  P. Cloetens,et al.  Quantitative comparison of direct phase retrieval algorithms in in-line phase tomography. , 2008, Medical physics.

[2]  Max A. Viergever,et al.  elastix: A Toolbox for Intensity-Based Medical Image Registration , 2010, IEEE Transactions on Medical Imaging.

[3]  D. Dyck,et al.  Wave function reconstruction in HRTEM: the parabola method , 1996 .

[4]  K. Nugent,et al.  Quantitative Phase Imaging Using Hard X Rays. , 1996, Physical review letters.

[5]  A. Momose,et al.  Phase-contrast radiographs of nonstained rat cerebellar specimen. , 1995, Medical physics.

[6]  P. Cloetens,et al.  Mixed transfer function and transport of intensity approach for phase retrieval in the Fresnel region. , 2007, Optics letters.

[7]  P. Cloetens,et al.  Holotomography: Quantitative phase tomography with micrometer resolution using hard synchrotron radiation x rays , 1999 .

[8]  Françoise Peyrin,et al.  X-ray in-line phase tomography of multimaterial objects. , 2012, Optics letters.

[9]  M. Teague Irradiance moments: their propagation and use for unique retrieval of phase , 1982 .

[10]  S. Rit,et al.  Dose fractionation in synchrotron radiation x-ray phase micro-tomography , 2015, Physics in medicine and biology.

[11]  Emmanuel Brun,et al.  Cartilage and Soft Tissue Imaging Using X-rays: Propagation-Based Phase-Contrast Computed Tomography of the Human Knee in Comparison With Clinical Imaging Techniques and Histology , 2014, Investigative radiology.

[12]  P. Cloetens,et al.  Optimization of phase contrast imaging using hard x rays , 2005 .

[13]  Simon Rit,et al.  The Reconstruction Toolkit (RTK), an open-source cone-beam CT reconstruction toolkit based on the Insight Toolkit (ITK) , 2014 .

[14]  P. Cloetens,et al.  X-Ray Phase Nanotomography Resolves the 3D Human Bone Ultrastructure , 2012, PloS one.

[15]  J. Goodman Introduction to Fourier optics , 1969 .

[16]  Timm Weitkamp,et al.  Quantitative phase and absorption tomography with an X-ray grating interferometer and synchrotron radiation , 2011 .

[17]  Stefan Klein,et al.  Fast parallel image registration on CPU and GPU for diagnostic classification of Alzheimer's disease , 2013, Front. Neuroinform..

[18]  Paul A. Viola,et al.  Alignment by Maximization of Mutual Information , 1997, International Journal of Computer Vision.

[19]  Gabor T. Herman,et al.  Fundamentals of Computerized Tomography: Image Reconstruction from Projections , 2009, Advances in Pattern Recognition.

[20]  Francois L. E. Usseglio-Viretta,et al.  Multi-scale 3D imaging of absorbing porous materials for solid oxide fuel cells , 2014, Journal of Materials Science.

[21]  Françoise Peyrin,et al.  3D IMAGING USING COHERENT SYNCHROTRON RADIATION , 2011 .

[22]  Greg Gbur,et al.  Diffraction tomography without phase information. , 2002, Optics letters.

[23]  Françoise Peyrin,et al.  Priors for X-ray in-line phase tomography of heterogeneous objects , 2014, Philosophical Transactions of the Royal Society A: Mathematical, Physical and Engineering Sciences.

[24]  Guy Marchal,et al.  Multimodality image registration by maximization of mutual information , 1997, IEEE Transactions on Medical Imaging.

[25]  Françoise Peyrin,et al.  Regularization of Phase Retrieval With Phase-Attenuation Duality Prior for 3-D Holotomography , 2010, IEEE Transactions on Image Processing.

[26]  Emmanuel Brun,et al.  PyHST2: an hybrid distributed code for high speed tomographic reconstruction with iterative reconstruction and a priori knowledge capabilities , 2013, ArXiv.

[27]  A. Snigirev,et al.  On the possibilities of x-ray phase contrast microimaging by coherent high-energy synchrotron radiation , 1995 .

[28]  Peter Cloetens,et al.  Whispering to the Deaf: Communication by a Frog without External Vocal Sac or Tympanum in Noisy Environments , 2011, PloS one.

[29]  Françoise Peyrin,et al.  Observation of microstructure and damage in materials by phase sensitive radiography and tomography , 1997 .

[30]  P. Zysset,et al.  In situ micropillar compression reveals superior strength and ductility but an absence of damage in lamellar bone. , 2014, Nature materials.

[31]  Syed Naeem Ahmed,et al.  Physics and Engineering of Radiation Detection , 2007 .

[32]  S. Wilkins,et al.  Simultaneous phase and amplitude extraction from a single defocused image of a homogeneous object , 2002, Journal of microscopy.