Amperometric Glucose Sensors for Whole Blood Measurement Based on Dehydrogenase Enzymes

© 2012 Cardosi and Liu, licensee InTech. This is an open access chapter distributed under the terms of the Creative Commons Attribution License (http://creativecommons.org/licenses/by/3.0), which permits unrestricted use, distribution, and reproduction in any medium, provided the original work is properly cited. Amperometric Glucose Sensors for Whole Blood Measurement Based on Dehydrogenase Enzymes

[1]  J. Duine,et al.  Reconstitution of membrane-integrated quinoprotein glucose dehydrogenase apoenzyme with PQQ and the holoenzyme's mechanism of action. , 1998, Biochemistry.

[2]  K. Kano,et al.  Potential-step coulometry of d-glucose using a novel FAD-dependent glucose dehydrogenase , 2006, Analytical and bioanalytical chemistry.

[3]  M. Cardosi,et al.  Synthesis and study of copolymer of vinylferrocene, acrylamide and 2-(diethylamino)ethyl methacrylate as a polymeric mediator for electrochemical biosensors , 2010 .

[4]  J. Marty,et al.  Reusable ethanol sensor based on a NAD+-dependent dehydrogenase without coenzyme addition , 1997 .

[5]  B. Zinman,et al.  Intensive diabetes treatment and cardiovascular disease in patients with type 1 diabetes. , 2005, The New England journal of medicine.

[6]  Q. Gao,et al.  An amperometric glucose biosensor based on layer-by-layer GOx-SWCNT conjugate/redox polymer multilayer on a screen-printed carbon electrode , 2011 .

[7]  Yukari Sato,et al.  Electrochemically amplified detection for lipopolysaccharide using ferrocenylboronic acid. , 2007, Biosensors & bioelectronics.

[8]  Nicollerat Ja Implications of the United Kingdom Prospective Diabetes Study , 1998, Diabetes Care.

[9]  Rodkey Fl,et al.  The effect of temperature on the oxidation-reduction potential of the diphosphopyridine nucleotide system. , 1959 .

[10]  E. Benjamin,et al.  Self-Monitoring of Blood Glucose: The Basics , 2002 .

[11]  M. Senda,et al.  Electron-transfer function of NAD+-immobilized alginic acid. , 1996, Biochimica et biophysica acta.

[12]  G. Chiari,et al.  The direct measurement of 3-beta-hydroxy butyrate enhances the management of diabetic ketoacidosis in children and reduces time and costs of treatment. , 2002, Diabetes, nutrition & metabolism.

[13]  C. W. Fuller,et al.  A simple procedure for covalent immobilization of NADH in a soluble and enzymically active form. , 1980, European journal of biochemistry.

[14]  H. S. Kim,et al.  Functionalization of a poly(amidoamine) dendrimer with ferrocenyls and its application to the construction of a reagentless enzyme electrode. , 2000, Analytical chemistry.

[15]  H. S. Lee,et al.  Thin film bienzyme amperometric biosensors based on polymeric redox mediators with electrostatic bipolar protecting layer , 1995 .

[16]  W. Blaedel,et al.  Study of the electrochemical oxidation of reduced nicotinamide adenine dinucleotide. , 1975, Analytical chemistry.

[17]  A. Turner The realisation of electron transfer from biological molecules to electrodes , 1987 .

[18]  K. Mosbach,et al.  A new immobilized NAD+ analogue, its application in affinity chromatography and as a functioning coenzyme. , 1973, European journal of biochemistry.

[19]  Haitao Zheng,et al.  Assembly of alternating polymerized mediator, polymerized coenzyme, and enzyme modified electrode by layer-by-layer adsorption technique , 2005 .

[20]  N. Mano,et al.  Molecular lego for the assembly of biosensing layers. , 2005, Talanta.

[21]  L. C. Clark,et al.  ELECTRODE SYSTEMS FOR CONTINUOUS MONITORING IN CARDIOVASCULAR SURGERY , 1962 .

[22]  P. Vadgama,et al.  Reagentless enzyme electrode for malate based on modified polymeric membranes , 2000 .

[23]  Odette Parry,et al.  Blood glucose self-monitoring in non-insulin-treated type 2 diabetes: a qualitative study of patients' perspectives. , 2004, The British journal of general practice : the journal of the Royal College of General Practitioners.

[24]  Rodkey Fl Oxidation-reduction potentials of the diphosphopyridine nucleotide system. , 1952 .

[25]  P. Bergveld,et al.  A flow-through amperometric sensor based on dialysis tubing and free enzyme reactors. , 2001, Biosensors & bioelectronics.

[26]  Adam Heller,et al.  Electron-conducting redox hydrogels: Design, characteristics and synthesis. , 2006, Current opinion in chemical biology.

[27]  R. Klein,et al.  Implications of the United kingdom prospective diabetes study. , 2003, Diabetes care.

[28]  Y. Yamada,et al.  Topological analysis of quinoprotein glucose dehydrogenase in Escherichia coli and its ubiquinone-binding site. , 1993, The Journal of biological chemistry.

[29]  P. Zappelli,et al.  Preparation of coenzymic activity of soluble polyethyleneimine-bound NADP+ derivatives. , 1977, European journal of biochemistry.

[30]  Nataliya V. Roznyatovskaya,et al.  Conducting polymers in chemical sensors and arrays. , 2008, Analytica chimica acta.

[31]  Nicole Jaffrezic-Renault,et al.  Amperometric enzyme biosensors: Past, present and future , 2008 .

[32]  H. Maeda,et al.  The synthesis of new polymer derivatives of ATP by radical copolymerization and their coenzymic activity. , 1981 .

[33]  J. Marty,et al.  Bi-enzyme amperometric d-lactate sensor using macromolecular NAD+ , 1995 .

[34]  W. Schuhmann,et al.  Polypyrrole-entrapped quinohemoprotein alcohol dehydrogenase. Evidence for direct electron transfer via conducting-polymer chains. , 1999, Analytical chemistry.

[35]  H. B. White 1 – Evolution of Coenzymes and the Origin of Pyridine Nucleotides , 1982 .

[36]  Kazuhiko Ishihara,et al.  Poly(vinylferrocene-co-2-hydroxyethyl methacrylate) mediator as immobilized enzyme membrane for the fabrication of amperometric glucose sensor , 2009 .

[37]  Simona Serban,et al.  Synergetic effect for NADH oxidation of ferrocene and zeolite in modified carbon paste electrodes. New approach for dehydrogenase based biosensors. , 2004, Biosensors & bioelectronics.

[38]  O. Eray,et al.  Point of Care Blood Ketone Testing of Diabetic Patients in the Emergency Department , 2004, Endocrine research.

[39]  Itamar Willner,et al.  Integration of polyaniline/poly(acrylic acid) films and redox enzymes on electrode supports: an in situ electrochemical/surface plasmon resonance study of the bioelectrocatalyzed oxidation of glucose or lactate in the integrated bioelectrocatalytic systems. , 2002, Journal of the American Chemical Society.

[40]  G. Hicks,et al.  The Enzyme Electrode , 1967, Nature.

[41]  Norman Fleischer,et al.  The effect of intensive treatment of diabetes on the development and progression of long-term complications in insulin-dependent diabetes mellitus. The Diabetes Control and Complications Trial Research Group. , 1993 .

[42]  Z. Zaman,et al.  Effect of non-glucose sugars and haematocrit on glucose measurements with Roche Accu-Chek Performa glucose strips , 2010, Annals of clinical biochemistry.

[43]  G. S. Wilson,et al.  Biosensors : fundamentals and applications , 1987 .

[44]  Koji Sode,et al.  SPCE Based Glucose Sensor Employing Novel Thermostable Glucose Dehydrogenase, FADGDH: Blood Glucose Measurement with 150nL Sample in One Second , 2007, Journal of diabetes science and technology.

[45]  I. Urabe,et al.  Synthesis and kinetic properties of a new NAD+ derivative carrying a vinyl group. , 1977, European journal of biochemistry.

[46]  C. Mousty Sensors and biosensors based on clay-modified electrodes: new trends , 2004 .

[47]  B. Dijkstra,et al.  Active-site structure of the soluble quinoprotein glucose dehydrogenase complexed with methylhydrazine: a covalent cofactor-inhibitor complex. , 1999, Proceedings of the National Academy of Sciences of the United States of America.

[48]  W. Göpel,et al.  Optimized biosensor for whole blood measurements using a new cellulose based membrane. , 1994, Biosensors & bioelectronics.

[49]  J. Duine,et al.  Glucose dehydrogenase from Acinetobacter calcoaceticus , 1979, FEBS letters.

[50]  Nigel J. Forrow,et al.  Development of a commercial amperometric biosensor electrode for the ketone D-3-hydroxybutyrate. , 2005, Biosensors & bioelectronics.

[51]  Mikio Sakakibara,et al.  Electrochemical reduction of immobilized NADP+ on a polymer modified electrode with a co-polymerized mediator , 2002 .

[52]  Simona Serban,et al.  Redox-flexible NADH oxidase biosensor: A platform for various dehydrogenase bioassays and biosensors , 2006 .

[53]  F L RODKEY The effect of temperature on the oxidation-reduction potential of the diphosphopyridine nucleotide system. , 1959, The Journal of biological chemistry.

[54]  D. Ruta,et al.  Frequency of blood glucose monitoring in relation to glycaemic control: observational study with diabetes database , 1999, BMJ.

[55]  Suxia Zhang,et al.  Multilayered construction of glucose oxidase and poly(allylamine)ferrocene on gold electrodes by means of layer-by-layer covalent attachment , 2004 .

[56]  S. Cosnier,et al.  A new strategy for the construction of amperometric dehydrogenase electrodes based on laponite gel-methylene blue polymer as the host matrix , 1996 .

[57]  S H Kaplan,et al.  The impact of blood glucose self-monitoring on metabolic control and quality of life in type 2 diabetic patients: an urgent need for better educational strategies. , 2001, Diabetes care.

[58]  W. Gernand,et al.  Analytical evaluation of the Optium Xido blood glucose meter , 2008, Clinical chemistry and laboratory medicine.

[59]  G. S. Wilson,et al.  Glucose microbiosensor based on alumina sol-gel matrix/electropolymerized composite membrane. , 2002, Biosensors & bioelectronics.

[60]  W. Schuhmann,et al.  Reagentless biosensors based on co-entrapment of a soluble redox polymer and an enzyme within an electrochemically deposited polymer film. , 2002, Biosensors & bioelectronics.

[61]  Joseph Wang,et al.  Electrochemical Glucose Biosensors , 2008 .

[62]  A. English,et al.  NAD(P)H Sensors Based on Enzyme Entrapment in Ferrocene-Containing Polyacrylamide-Based Redox Gels , 1998 .

[63]  Jianjun Xia,et al.  Amperometric glucose biosensor based on immobilization of glucose oxidase in electropolymerized o-aminophenol film at copper-modified gold electrode , 2005 .

[64]  Silvana Andreescu,et al.  Stable enzyme biosensors based on chemically synthesized Au-polypyrrole nanocomposites. , 2007, Biosensors & bioelectronics.

[65]  M. Lilly,et al.  The preparation of soluble high molecular weight NAD derivative active as a cofactor. , 1972, Biochimica et biophysica acta.

[66]  Ronald Brazg,et al.  A continuous glucose sensor based on wired enzyme technology -- results from a 3-day trial in patients with type 1 diabetes. , 2003, Diabetes technology & therapeutics.

[67]  S. Higson,et al.  Diamond-like carbon coated microporous polycarbonate as a composite barrier for a glucose enzyme electrode , 1993 .

[68]  C. O’Sullivan,et al.  Electrocatalytic sensing of NADH on a glassy carbon electrode modified with electrografted o-aminophenol film , 2006 .

[69]  J. Anzai,et al.  Multilayer membranes via layer-by-layer deposition of glucose oxidase and Au nanoparticles on a Pt electrode for glucose sensing , 2007 .

[70]  M. Watanabe,et al.  Characterization of poly(vinylferrocene-co-2-hydroxyethyl methacrylate) for use as electron mediator in enzymatic glucose sensor , 1998 .

[71]  Haitao Zheng,et al.  Layer-by-layer assembly of enzymes and polymerized mediator on electrode surface by electrostatic adsorption , 2004 .

[72]  Y. Bae,et al.  A sulfonamide based glucose-responsive hydrogel with covalently immobilized glucose oxidase and catalase. , 2003, Journal of controlled release : official journal of the Controlled Release Society.

[73]  B. Guerci,et al.  Accuracy of an electrochemical sensor for measuring capillary blood ketones by fingerstick samples during metabolic deterioration after continuous subcutaneous insulin infusion interruption in type 1 diabetic patients. , 2003, Diabetes care.

[74]  F. Rodkey Oxidation-reduction potentials of the diphosphopyridine nucleotide system. , 1955, The Journal of biological chemistry.