Design and cadaveric validation of a novel device to quantify knee stability during total knee arthroplasty.

The success of total knee arthroplasty depends, in part, on the ability of the surgeon to properly manage the soft tissues surrounding the joint, but an objective definition as to what constitutes acceptable postoperative joint stability does not exist. Such a definition may not exist due to lack of suitable instrumentation, as joint stability is currently assessed by visual inspection while the surgeon manipulates the joint. Having the ability to accurately and precisely measure knee stability at the time of surgery represents a key requirement in the process of objectively defining acceptable joint stability. Therefore, we created a novel sterilizable device to allow surgeons to measure varus-valgus, internal-external, or anterior-posterior stability of the knee during a total knee arthroplasty. The device can be quickly adjusted between 0 deg and 90 deg of knee flexion. The device interfaces with a custom surgical navigation system, which records the resultant rotations or translations of the knee while the surgeon applies known loads to a patient's limb with a handle instrumented with a load cell. We validated the performance of the device by having volunteers use it to apply loads to a mechanical linkage that simulated a knee joint; we then compared the joint moments calculated by our stability device against those recorded by a load cell in the simulated knee joint. Validation of the device showed low mean errors (less than 0.21 ± 1.38 Nm and 0.98 ± 3.93 N) and low RMS errors (less than 1.5 Nm and 5 N). Preliminary studies from total knee arthroplasties performed on ten cadaveric specimens also demonstrate the utility of our new device. Eventually, the use of this device may help determine how intra-operative knee stability relates to postoperative function and could lead to an objective definition of knee stability and more efficacious surgical techniques.

[1]  Scott L Delp,et al.  The variability of femoral rotational alignment in total knee arthroplasty. , 2005, The Journal of bone and joint surgery. American volume.

[2]  Robert A Siston,et al.  Coronal Plane Stability Before and After Total Knee Arthroplasty , 2007, Clinical orthopaedics and related research.

[3]  J. Harlaar,et al.  Reproducibility of instrumented knee joint laxity measurement in healthy subjects. , 2006, Rheumatology.

[4]  M L Hull,et al.  Apparatus to obtain rotational flexibility of the human knee under moment loads in vivo. , 1991, Journal of biomechanics.

[5]  T. Fehring,et al.  Knee instability after total knee arthroplasty. , 1994, Clinical orthopaedics and related research.

[6]  G. Scuderi**,et al.  Accuracy of soft tissue balancing in total knee arthroplasty. , 2000, The Journal of arthroplasty.

[7]  J. Bellemans,et al.  Soft Tissue Balance in Total Knee Arthroplasty: Does Stress Relaxation Occur Perioperatively? , 2006, Clinical orthopaedics and related research.

[8]  Melinda J. Cromie,et al.  Posterior cruciate ligament removal contributes to abnormal knee motion during posterior stabilized total knee arthroplasty , 2008, Journal of orthopaedic research : official publication of the Orthopaedic Research Society.

[9]  S. Shultz,et al.  Bilateral Asymmetries in Clinical Measures of Lower-Extremity Anatomic Characteristics , 2007, Clinical journal of sport medicine : official journal of the Canadian Academy of Sport Medicine.

[10]  M L Hull,et al.  Rotational flexibility of the human knee due to varus/valgus and axial moments in vivo. , 1991, Journal of biomechanics.

[11]  J O Galante,et al.  Wear patterns on retrieved polyethylene tibial inserts and their relationship to technical considerations during total knee arthroplasty. , 1994, Clinical orthopaedics and related research.

[12]  B. Beynnon,et al.  Measurement of varus–valgus and internal–external rotational knee laxities in vivo—part i: assessment of measurement reliability and bilateral asymmetry , 2007, Journal of orthopaedic research : official publication of the Orthopaedic Research Society.

[13]  K. Markolf,et al.  In vivo knee stability. A quantitative assessment using an instrumented clinical testing apparatus. , 1978, The Journal of bone and joint surgery. American volume.

[14]  Braden C Fleming,et al.  Measurement of anterior–posterior knee laxity: a comparison of three techniques , 2002, Journal of orthopaedic research : official publication of the Orthopaedic Research Society.

[15]  Richard D Komistek,et al.  Correlation of compartment pressure data from an intraoperative sensing device with postoperative fluoroscopic kinematic results in TKA patients. , 2005, Journal of biomechanics.

[16]  K. Rudolph,et al.  Muscle stabilization strategies in people with medial knee osteoarthritis: The effect of instability , 2008, Journal of orthopaedic research : official publication of the Orthopaedic Research Society.

[17]  Scott L Delp,et al.  Surgical navigation for total knee arthroplasty: a perspective. , 2007, Journal of biomechanics.

[18]  Scott L Delp,et al.  Intraoperative passive kinematics of osteoarthritic knees before and after total knee arthroplasty , 2006, Journal of orthopaedic research : official publication of the Orthopaedic Research Society.

[19]  P. Neyret,et al.  Tibiofemoral instability in primary total knee replacement: a review, Part 1: Basic principles and classification. , 2005, The Knee.

[20]  K. Markolf,et al.  Stiffness and laxity of the knee--the contributions of the supporting structures. A quantitative in vitro study. , 1976, The Journal of bone and joint surgery. American volume.

[21]  J. Callaghan,et al.  Current Etiologies and Modes of Failure in Total Knee Arthroplasty Revision , 2006, Clinical orthopaedics and related research.

[22]  L. Sharma,et al.  Laxity in healthy and osteoarthritic knees. , 1999, Arthritis and rheumatism.

[23]  W. Maloney,et al.  Revision Total Knee Arthroplasty for Restricted Motion , 2005, Clinical orthopaedics and related research.

[24]  Y. Yoshioka,et al.  Tibial anatomy and functional axes , 1989, Journal of orthopaedic research : official publication of the Orthopaedic Research Society.

[25]  J. Insall,et al.  Total knee arthroplasty , 2015 .

[26]  Johan Bellemans,et al.  What should the surgeon aim for when performing computer-assisted total knee arthroplasty? , 2005, The Journal of bone and joint surgery. American volume.

[27]  L. Dorr,et al.  Rationale of the Knee Society clinical rating system. , 1989, Clinical orthopaedics and related research.

[28]  R. Warren,et al.  An in vitro biomechanical evaluation of anterior-posterior motion of the knee. Tibial displacement, rotation, and torque. , 1982, The Journal of bone and joint surgery. American volume.