Modeling of frequency domain control of shunt active power filter using MATLAB Simulink and Power System Blockset

This paper presents modeling and simulation of a shunt active power filter in frequency domain, using MATLAB and its tools Simulink and Power System Blocket. The proposed method offers many additional features over other methods. It attributes the responsibility of utility and customer at PCC. It provides an additional feature of compensation of either harmonics only, or the compensation of both harmonics and reactive power simultaneously, based on the desired capacity of the APF

[1]  Hirofumi Akagi,et al.  Instantaneous Reactive Power Compensators Comprising Switching Devices without Energy Storage Components , 1984, IEEE Transactions on Industry Applications.

[2]  G. K. Dubey,et al.  An instantaneous reactive volt-ampere compensator and harmonic suppressor system , 1999 .

[3]  Hari Om Gupta,et al.  Simulation and Experimental Investigations on a Shunt Active Power Filter for Harmonics and Reactive Power Compensation , 2003 .

[4]  Hirofumi Akagi,et al.  A study of active power filters using quad-series voltage-source PWM converters for harmonic compensation , 1990 .

[5]  W. M. Grady,et al.  Minimizing network harmonic voltage distortion with an active power line conditioner , 1991 .

[6]  G.-H. Choe,et al.  A new injection method for AC harmonic elimination by active power filter , 1988 .

[7]  W. M. Grady,et al.  Survey of active power line conditioning methodologies , 1990 .

[8]  W. M. Grady,et al.  The application of network objective functions for actively minimizing the impact of voltage harmonics in power systems , 1992 .

[9]  Takeshi Furuhashi,et al.  A study on the theory of instantaneous reactive power , 1990 .

[10]  Luis Morán,et al.  Control system for three-phase active power filter which simultaneously compensates power factor and unbalanced loads , 1995, IEEE Trans. Ind. Electron..

[11]  Shyh-Jier Huang,et al.  A control algorithm for three-phase three-wired active power filters under nonideal mains voltages , 1999 .

[12]  Bhim Singh,et al.  Computer-Aided Modeling and Simulation of Active Power Filters , 1999 .

[13]  H.O. Gupta,et al.  A control algorithm for compensation of customer-generated harmonics and reactive power , 2004, IEEE Transactions on Power Delivery.

[14]  D Pradeep Kumar Investigations on shunt active power filter for power quality improvement , 2007 .

[15]  David A. Torrey,et al.  A passive series, active shunt filter for high power applications , 2001 .

[16]  Kamal Al-Haddad,et al.  A review of active filters for power quality improvement , 1999, IEEE Trans. Ind. Electron..

[17]  Mauricio Aredes,et al.  Three-phase four-wire shunt active filter control strategies , 1997 .

[18]  Hirofumi Akagi,et al.  Control Strategy of Active Power Filters Using Multiple Voltage-Source PWM Converters , 1986, IEEE Transactions on Industry Applications.