Design and Performance Evaluation of a Wearable Sensing System for Lower-Limb Exoskeleton

Because the target users of the assistive-type lower extremity exoskeletons (ASLEEs) are those who suffer from lower limb disabilities, customized gait is adopted for the control of ASLEEs. However, the customized gait is unable to provide stable motion for variable terrain, for example, flat, uphill, downhill, and soft ground. The purpose of this paper is to realize gait detection and environment feature recognition for AIDER by developing a novel wearable sensing system. The wearable sensing system employs 7 force sensors as a sensing matrix to achieve high accuracy of ground reaction force detection. There is one more IMU sensor that is integrated into the structure to detect the angular velocity. By fusing force and angular velocity data, four typical terrain features can be recognized successfully, and the recognition rate can reach up to 93%.

[1]  Hong Cheng,et al.  Minimizing Human-Exoskeleton Interaction Force Using Compensation for Dynamic Uncertainty Error with Adaptive RBF Network , 2016, J. Intell. Robotic Syst..

[2]  Hongliang Guo,et al.  Hierarchical Interactive Learning for a HUman-Powered Augmentation Lower EXoskeleton , 2016, 2016 IEEE International Conference on Robotics and Automation (ICRA).

[3]  Jian Huang,et al.  Fall detection for elderly by using an intelligent cane robot based on center of pressure (COP) stability theory , 2014, 2014 International Symposium on Micro-NanoMechatronics and Human Science (MHS).

[4]  D. De Clercq,et al.  The trajectory of the centre of pressure during barefoot running as a potential measure for foot function. , 2008, Gait & posture.

[5]  Yoshiyuki Sankai,et al.  HAL: Hybrid Assistive Limb Based on Cybernics , 2007, ISRR.

[6]  M. Molinari,et al.  The embodiment of assistive devices-from wheelchair to exoskeleton. , 2016, Physics of life reviews.

[7]  Hannes Bleuler,et al.  EXiO—A Brain-Controlled Lower Limb Exoskeleton for Rhesus Macaques , 2017, IEEE Transactions on Neural Systems and Rehabilitation Engineering.

[8]  Goutam Sanyal,et al.  An efficient face recognition approach using PCA and minimum distance classifier , 2011, 2011 International Conference on Image Information Processing.

[9]  Joseph A. Paradiso,et al.  Gait Analysis Using a Shoe-Integrated Wireless Sensor System , 2008, IEEE Transactions on Information Technology in Biomedicine.

[10]  Edwin van Asseldonk,et al.  Ambulatory Estimation of Center of Mass Displacement During Walking , 2009, IEEE Transactions on Biomedical Engineering.

[11]  Eryk Dutkiewicz,et al.  Freezing of Gait Detection in Parkinson's Disease: A Subject-Independent Detector Using Anomaly Scores , 2017, IEEE Transactions on Biomedical Engineering.

[12]  Ye Chen,et al.  Design of a wearable sensing system for a lower extremity exoskeleton , 2017, 2017 IEEE International Conference on Mechatronics and Automation (ICMA).

[13]  Marcela Munera,et al.  Lokomat therapy in Colombia: Current state and cognitive aspects , 2017, 2017 International Conference on Rehabilitation Robotics (ICORR).

[14]  Qiming Chen,et al.  Adaptive stair-ascending and stair-descending strategies for powered lower limb exoskeleton , 2017, 2017 IEEE International Conference on Mechatronics and Automation (ICMA).

[15]  Tao Liu,et al.  The Lower Limbs Kinematics Analysis by Wearable Sensor Shoes , 2016, IEEE Sensors Journal.

[16]  V. Reggie Edgerton,et al.  Iron ‘ElectriRx’ man: Overground stepping in an exoskeleton combined with noninvasive spinal cord stimulation after paralysis , 2015, 2015 37th Annual International Conference of the IEEE Engineering in Medicine and Biology Society (EMBC).

[17]  H. Kazerooni,et al.  Biomechanical design of the Berkeley lower extremity exoskeleton (BLEEX) , 2006, IEEE/ASME Transactions on Mechatronics.

[18]  Hong Cheng,et al.  Interactive learning for sensitivity factors of a human-powered augmentation lower exoskeleton , 2015, 2015 IEEE/RSJ International Conference on Intelligent Robots and Systems (IROS).

[19]  P. O'Connor,et al.  Trends in spinal cord injury. , 2006, Accident; analysis and prevention.

[20]  Sung Hoon Kim,et al.  Control scheme and networked control architecture for the Berkeley lower extremity exoskeleton (BLEEX) , 2006, Proceedings 2006 IEEE International Conference on Robotics and Automation, 2006. ICRA 2006..

[21]  Kenji Suzuki,et al.  Standing Mobility Device With Passive Lower Limb Exoskeleton for Upright Locomotion , 2018, IEEE/ASME Transactions on Mechatronics.

[22]  Pierre Asselin,et al.  Heart rate and oxygen demand of powered exoskeleton-assisted walking in persons with paraplegia. , 2015, Journal of rehabilitation research and development.

[23]  Tao Liu,et al.  Three-dimensional lower limb kinematic and kinetic analysis based on a wireless sensor system , 2011, 2011 IEEE International Conference on Robotics and Automation.

[24]  Zheng Wei,et al.  Application of kernel PCA for foetal ECG estimation , 2018 .

[25]  Shuji Hashimoto,et al.  Haptic Sensing Foot System for Humanoid Robot and Ground Recognition With One-Leg Balance , 2011, IEEE Transactions on Industrial Electronics.

[26]  Paolo Dario,et al.  Realization of biped walking on soft ground with stabilization control based on gait analysis , 2012, 2012 IEEE/RSJ International Conference on Intelligent Robots and Systems.

[27]  Mukul Talaty,et al.  Differentiating ability in users of the ReWalkTM powered exoskeleton: An analysis of walking kinematics , 2013, 2013 IEEE 13th International Conference on Rehabilitation Robotics (ICORR).

[28]  Yu Zheng Chong,et al.  Design and development of inexpensive pneumatically-powered assisted knee-ankle-foot orthosis for gait rehabilitation-preliminary finding , 2012, 2012 International Conference on Biomedical Engineering (ICoBE).

[29]  Elliott J. Rouse,et al.  The VSPA Foot: A Quasi-Passive Ankle-Foot Prosthesis With Continuously Variable Stiffness , 2017, IEEE Transactions on Neural Systems and Rehabilitation Engineering.

[30]  Kuan Zhang,et al.  Gait characteristics of overweight and obese children with different ages , 2014, 2014 7th International Conference on Biomedical Engineering and Informatics.

[31]  Johan Potgieter,et al.  A review of commercially available exoskeletons' capabilities , 2017, 2017 24th International Conference on Mechatronics and Machine Vision in Practice (M2VIP).