Energy Efficiency Indicators for Assessing Construction Systems Storing Renewable Energy: Application to Phase Change Material-Bearing Façades

Assessing the performance or energy efficiency of a single construction element by itself is often a futile exercise. That is not the case, however, when an element is designed, among others, to improve building energy performance by harnessing renewable energy in a process that requires a source of external energy. Harnessing renewable energy is acquiring growing interest in Mediterranean climates as a strategy for reducing the energy consumed by buildings. When such reduction is oriented to lowering demand, the strategy consists in reducing the building’s energy needs with the use of construction elements able to passively absorb, dissipate, or accumulate energy. When reduction is pursued through M&E services, renewable energy enhances building performance. The efficiency of construction systems that use renewable energy but require a supplementary power supply to operate can be assessed by likening these systems to regenerative heat exchangers built into the building. The indicators needed for this purpose are particularly useful for designers, for they can be used to compare the efficiency or performance to deliver an optimal design for each building. This article proposes a series of indicators developed to that end and describes their application to facades bearing phase change materials (PCMs).

[1]  Luisa F. Cabeza,et al.  Thermal analysis of a ventilated facade with PCM for cooling applications , 2013 .

[2]  Luisa F. Cabeza,et al.  Materials used as PCM in thermal energy storage in buildings: A review , 2011 .

[3]  Luisa F. Cabeza,et al.  Building integration of PCM for natural cooling of buildings , 2013 .

[4]  A. Sharma,et al.  Review on thermal energy storage with phase change materials and applications , 2009 .

[5]  R. Ackermann,et al.  Cryogenic Regenerative Heat Exchangers , 2013 .

[6]  A. Bejan,et al.  Thermal Energy Storage: Systems and Applications , 2002 .

[7]  V. V. Tyagi,et al.  PCM thermal storage in buildings: A state of art , 2007 .

[8]  Marcus Bianchi,et al.  Verification and validation of EnergyPlus phase change material model for opaque wall assemblies , 2012 .

[9]  Daniel E. Fisher,et al.  EnergyPlus: creating a new-generation building energy simulation program , 2001 .

[10]  Javier Mazo,et al.  Modeling a radiant floor system with Phase Change Material (PCM) integrated into a building simulation tool: Analysis of a case study of a floor heating system coupled to a heat pump , 2012 .

[11]  Luisa F. Cabeza,et al.  Numerical study on the thermal performance of a ventilated facade with PCM , 2013 .

[12]  Joseph Virgone,et al.  Development and validation of a new TRNSYS type for the simulation of external building walls containing PCM , 2010 .

[13]  Gregory Nellis,et al.  Regenerative heat exchangers with significant entrained fluid heat capacity , 2006 .

[14]  Martin Belusko,et al.  An effectiveness-NTU technique for characterising tube-in-tank phase change thermal energy storage systems , 2012 .

[15]  A. John Willmott Dynamics of Regenerative Heat Transfer , 2001 .

[16]  E. Kossecka,et al.  Numerical and Experimental Analysis of Building Envelopes Containing Blown Fiberglass Insulation Thermally Enhanced with Phase Change Material ( PCM ) , 2010 .

[17]  C. O. Pedersen,et al.  ADVANCED ZONE SIMULATION IN ENERGYPLUS: INCORPORATION OF VARIABLE PROPERTIES AND PHASE CHANGE MATERIAL (PCM) CAPABILITY , 2007 .

[18]  Xin Wang,et al.  Review on thermal performance of phase change energy storage building envelope , 2009 .

[19]  Paulo Santos,et al.  Review of passive PCM latent heat thermal energy storage systems towards buildings’ energy efficiency , 2013 .

[20]  R. Lehtiniemi,et al.  Numerical and experimental investigation of melting and freezing processes in phase change material storage , 2004 .

[21]  Luisa F. Cabeza,et al.  An approach to the simulation of PCMs in building applications using TRNSYS , 2005 .