Barbed micro-spikes for micro-scale biopsy

Single-crystal silicon planar micro-spikes with protruding barbs are developed for micro-scale biopsy and the feasibility of using the micro-spike as a micro-scale biopsy tool is evaluated for the first time. The fabrication process utilizes a deep silicon etch to define the micro-spike outline, resulting in protruding barbs of various shapes. Shanks of the fabricated micro-spikes are 3 mm long, 100 ?m thick and 250 ?m wide. Barbs protruding from micro-spike shanks facilitate the biopsy procedure by tearing off and retaining samples from target tissues. Micro-spikes with barbs successfully extracted tissue samples from the small intestines of the anesthetized pig, whereas micro-spikes without barbs failed to obtain a biopsy sample. Parylene coating can be applied to improve the biocompatibility of the micro-spike without deteriorating the biopsy function of the micro-spike. In addition, to show that the biopsy with the micro-spike can be applied to tissue analysis, samples obtained by micro-spikes were examined using immunofluorescent staining. Nuclei and F-actin of cells which are extracted by the micro-spike from a transwell were clearly visualized by immunofluorescent staining.

[1]  J. Rizzo,et al.  A performance, safety and cost comparison of reusable and disposable endoscopic biopsy forceps: a prospective, randomized trial. , 2000, Gastrointestinal endoscopy.

[2]  P. Krulevitch,et al.  A practical microgripper by fine alignment, eutectic bonding and SMA actuation , 1995 .

[3]  A. B. Frazier,et al.  Characterization of surface micromachined metallic microneedles , 2003 .

[4]  Michael L. Reed,et al.  Silicon micro‐velcro , 1992 .

[5]  Dong-il Dan Cho,et al.  Why is (111) Silicon a Better Mechanical Material for MEMS , 2001 .

[6]  Karan V. I. S. Kaler,et al.  On the design of an electronic mosquito: design and analysis of the micro-needle , 2003, Proceedings International Conference on MEMS, NANO and Smart Systems.

[7]  Hiroyuki Fujita,et al.  Fabrication of a Micro Needle for a Trace Blood Test , 2002 .

[8]  David Hill,et al.  Design Engineering of Biomaterials for Medical Devices , 1998 .

[9]  V. Eckardt,et al.  Colonic perforation with endoscopic biopsy. , 1997, Gastrointestinal endoscopy.

[10]  Dong-il Dan Cho,et al.  In-plane single-crystal-silicon microneedles for minimally invasive microfluid systems , 2004 .

[11]  Dorian Liepmann,et al.  Microfabricated Polysilicon Microneedles for Minimally Invasive Biomedical Devices , 2000 .

[12]  Albert P. Pisano,et al.  Silicon, Parylene, and Silicon/Parylene Micro-Needles for Strength and Toughness , 2001 .

[13]  Robert Langer,et al.  A BioMEMS review: MEMS technology for physiologically integrated devices , 2004, Proceedings of the IEEE.

[14]  Keith J. Rebello,et al.  Applications of MEMS in surgery , 2004, Proceedings of the IEEE.