Mechanical behavior of tubular T-joint after fire

This paper presents experimental results of the post-fire behavior of tubular T-joints. The research aims at the failure modes and the residual strengths of the T-joints after fire. Three tests of full-scale tubular T-joints are conducted. The first one is carried out to study the mechanical behavior of T-joints under ambient temperature. The other two tests are performed to study the influence of pre-load, heating and cooling phase on residual load-bearing capacity of the tubular T-joints. The test results show that the sustained axial load on the brace has remarkable influence on the residual deflection of the T-joints which is cooled down to room temperature. The results of the experiments also indicate that the axial load level and heating and cooling history have more significant effects on the compressive stiffness of the T-joints than the residual strength. In the numerical study, the result of finite element model agrees well with the test result. The work in this paper provides a basis for further parametric analysis and theoretical study on the structural evaluation after fire.

[1]  Ai Kah Soh,et al.  Experimental investigation of a doubler-plate reinforced tubular T-joint subjected to combined loadings , 2001 .

[2]  Lin-Hai Han,et al.  Tests on Cyclic Behavior of Concrete-Filled Hollow Structural Steel Columns after Exposure to the ISO-834 Standard Fire , 2004 .

[3]  Chee Kiong Soh,et al.  Ultimate capacity of completely overlapped tubular joints. II: Behavioural study , 2001 .

[4]  Jincheng Zhao,et al.  An experimental study of the mechanical behavior of steel planar tubular trusses in a fire , 2010 .

[5]  Man-Biu Bill Wong,et al.  Effect of Torsion on Limiting Temperature of Steel Structures in Fire , 2006 .

[6]  L.M.R. Mesquita,et al.  Experimental and numerical research on the critical temperature of laterally unrestrained steel I beams , 2005 .

[7]  Guo-Qiang Li,et al.  Experiment on restrained steel beams subjected to heating and cooling , 2008 .

[8]  Lin-Hai Han,et al.  Effects of heating and loading histories on post-fire cooling behaviour of concrete-filled steel tubular columns , 2008 .

[9]  Wei Wang,et al.  Hysteretic behaviour of tubular joints under cyclic loading , 2007 .

[10]  Yan Xiao,et al.  Effects of sustained axial load and cooling phase on post-fire behaviour of concrete-filled steel tubular stub columns , 2009 .

[11]  M.M.K Lee,et al.  Strength, stress and fracture analyses of offshore tubular joints using finite elements , 1999 .

[12]  Lin-Hai Han,et al.  Concrete-filled hollow structural steel columns after exposure to ISO-834 fire standard , 2003 .

[13]  Lin-Hai Han,et al.  Behavior of Steel Beam to Concrete-Filled Steel Tubular Column Connections after Exposure to Fire , 2007 .

[14]  Yong Wang,et al.  A numerical study of large deflection behaviour of restrained steel beams at elevated temperatures , 2004 .

[15]  Xiao Xiong Zha,et al.  Nonlinear pre-fire and post-fire analysis of steel frames , 2005 .

[16]  Chee Kiong Soh,et al.  Ultimate capacity of completely overlapped tubular joints , 2001 .

[17]  Lin-Hai Han,et al.  Compressive and flexural behaviour of concrete filled steel tubes after exposure to standard fire , 2005 .

[18]  Guo Shi-xiong Analysis of Restrained Steel Beams Subjected to Temperature Increasing and Descending Part l:Theory , 2006 .

[19]  A. Llewelyn-Parry,et al.  Offshore Tubular T-Joints Reinforced with Internal Plain Annular Ring Stiffeners , 2004 .

[20]  Yong Wang An analysis of the global structural behaviour of the Cardington steel-framed building during the two BRE fire tests , 2000 .

[21]  M.M.K Lee,et al.  Strength of ring-stiffened tubular T-joints in offshore structures—: a numerical parametric study , 1999 .

[22]  Seng-Tjhen Lie,et al.  Fatigue Performance of Cracked Tubular T Joints under Combined Loads. II: Numerical , 2004 .

[23]  E. Lavernia,et al.  An experimental investigation , 1992, Metallurgical and Materials Transactions A.

[24]  Yong Wang,et al.  Experimental study of structural fire behaviour of steel beam to concrete filled tubular column assemblies with different types of joints , 2007 .

[25]  Lin-Hai Han,et al.  Experimental behaviour of steel beam to concrete-filled steel tubular (CFST) column connections after exposure to fire , 2005 .