A simplified network approach to the VAr control problem for radial distribution systems

A simplified network approach to the VAr (volt-ampere reactive) control problem in a distribution system with lateral branches is presented. According to this method, the power capacitors are assumed to be located optimally at the feeder branches. The optimal compensation levels (capacitor size) are represented by dependent current sources located at the branch connected buses. The solution of the equivalent circuit for the distribution system yields the values of the voltage at any bus. The actual compensation level is then determined by substituting the bus voltage in the dependent current source formula. The method can be used as an online controller and in the planning stage. It can be easily adapted in an expert system configuration. >

[1]  S. Civanlar,et al.  Optimal Design and Control Scheme for Continuous Capacitive Compensation of Distribution Feeders , 1983, IEEE Transactions on Power Apparatus and Systems.

[2]  R. F. Cook,et al.  Optimizing the Application of Shunt Capacitors for Reactive-Volt-Ampere Control and Loss Reduction , 1961, Transactions of the American Institute of Electrical Engineers. Part III: Power Apparatus and Systems.

[3]  Felix F. Wu,et al.  Efficient integer optimization algorithms for optimal coordination of capacitors and regulators , 1990 .

[4]  Richard F. Cook,et al.  Calculating Loss Reduction Afforded by Shunt Capacitor Application , 1964 .

[5]  S. Civanlar,et al.  Volt/Var Control on Distribution Systems with Lateral Branches Using Shunt Capacitors and Voltage Regulators Part II: The Solution Method , 1985, IEEE Transactions on Power Apparatus and Systems.

[6]  A. Y. Chikhani,et al.  A Computer Controlled VAR Compensator for Distribution Feeders , 1986, IEEE Power Engineering Review.

[7]  W. H. Kersting Radial distribution test feeders , 1991 .

[8]  Yahia Baghzouz,et al.  Shunt capacitor sizing for radial distribution feeders with distorted substation voltages , 1990 .

[9]  Suat Ertem,et al.  Optimal Shunt Capacitor Allocation by Nonlinear Programming , 1987, IEEE Transactions on Power Delivery.

[10]  J. Grainger,et al.  Optimal Capacitor Placement on Three-Phase Primary Feeders: Load and Feeder Unbalance Effects , 1983, IEEE Transactions on Power Apparatus and Systems.

[11]  J. J. Grainger,et al.  Design of a Real-Time Switching Control Scheme for Capacitive Compensation of Distribution Feeders , 1982, IEEE Power Engineering Review.

[12]  Nelson E. Chang,et al.  Generalized Equations on Loss Reduction with Shunt Capacitor , 1972 .

[13]  Y. G. Bae,et al.  Analytical Method of Capacitor Allocation on Distribution Primary Feeders , 1978, IEEE Transactions on Power Apparatus and Systems.

[14]  S. Civanlar,et al.  Discrete-Tap Control Scheme for Capacitive Compensation of Distribution Feeders , 1984, IEEE Transactions on Power Apparatus and Systems.

[15]  J. J. Grainger,et al.  Placement of Fixed and/or Nonsimultaneously Switched Capacitors on Unbalanced Three-Phase Feeders Involving Laterals , 1985, IEEE Power Engineering Review.

[16]  Jin-Cheng Wang,et al.  Optimal capacitor placements in distribution systems. I. A new formulation and the overall problem , 1990 .

[17]  S. Civanlar,et al.  Volt/Var Control on Distribution Systems with Lateral Branches Using Shunt Capacitors and Voltage Regulators Part I: The Overall Problem , 1985, IEEE Transactions on Power Apparatus and Systems.

[18]  Tsai-Hsiang Chen,et al.  Distribution system power flow analysis-a rigid approach , 1991 .

[19]  M. E. Baran,et al.  Optimal capacitor placement on radial distribution systems , 1989 .

[20]  M. M. Saied Optimal power factor correction , 1988 .

[21]  Nelson E. Chang,et al.  Determination of Primary-Feeder Losses , 1968 .

[22]  Hernando Dura,et al.  Optimum Number, Location, and Size of Shunt Capacitors in Radial Distribution Feeders A Dynamic Programming Approach , 1968 .

[23]  J. Grainger,et al.  Optimum Size and Location of Shunt Capacitors for Reduction of Losses on Distribution Feeders , 1981, IEEE Transactions on Power Apparatus and Systems.

[24]  S. Civanlar,et al.  Volt/Var Control on Distribution Systems with Lateral Branches Using Shunt Capacitors and Voltage Regulators Part III: The Numerical Results , 1985, IEEE Transactions on Power Apparatus and Systems.

[25]  J. J. Grainger,et al.  Optimal Voltage Dependent Continuous-Time Control of Reactive Power on Primary Feeders , 1984, IEEE Power Engineering Review.

[26]  Nelson E. Chang,et al.  Locating Shunt Capacitors on Primary Feeder for Voltage Control and Loss Reduction , 1969 .

[27]  A. Y. Chikhani,et al.  Control of Reactive Power in Distribution Systems with an End-Load and Varying Load Condition , 1985, IEEE Power Engineering Review.

[28]  R. Baldick,et al.  Approximation formulas for the distribution system: the loss function and voltage dependence , 1991, IEEE Power Engineering Review.

[29]  N. M. Neagle,et al.  Loss Reduction from Capacitors Installed on Primary Feeders [includes discussion] , 1956, Transactions of the American Institute of Electrical Engineers. Part III: Power Apparatus and Systems.

[30]  J. J. Grainger,et al.  Capacity Release by Shunt Capacitor Placement on Distribution Feeders: A New Voltage-Dependent Model , 1982, IEEE Power Engineering Review.

[31]  S. Rama Iyer,et al.  Optimal Reactive Power Allocation for Improved System Performance , 1984, IEEE Power Engineering Review.