Optical microbial biosensor for detection of methyl parathion pesticide using Flavobacterium sp. whole cells adsorbed on glass fiber filters as disposable biocomponent.

An optical microbial biosensor was described for the detection of methyl parathion pesticide. Whole cells of Flavobacterium sp. were immobilized by trapping in glass fiber filter and were used as biocomponent along with optic fiber system. Flavobacterium sp. has the organophosphorus hydrolase enzyme, which hydrolyzes the methyl parathion into detectable product p-nitrophenol. The immobilized microbial biocomponent was disposable, cost-effective and showed high reproducibility and uniformity. The detection of methyl parathion by the use of disposable microbial biocomponent with optical biosensor was simple, single step and direct measurement of very low quantity of the sample. The home made reaction vessel was small and needed only 75 microl of sample. A lower detection limit 0.3 microM methyl parathion was estimated from the linear range (4-80 microM) of calibration plot of organophosphorus hydrolase enzymatic assay. The applicability to synthetic methyl parathion spiked samples was demonstrated.

[1]  A Mulchandani,et al.  Biosensor for direct determination of organophosphate nerve agents using recombinant Escherichia coli with surface-expressed organophosphorus hydrolase. 1. Potentiometric microbial electrode. , 1998, Analytical chemistry.

[2]  Claude Durrieu,et al.  Optical whole-cell biosensor using Chlorella vulgaris designed for monitoring herbicides. , 2003, Biosensors & bioelectronics.

[3]  D. Munnecke,et al.  Enzymic detoxification of waste organophosphate pesticides , 1980 .

[4]  F. Spener,et al.  Microbial and cytoplasmic membrane-based potentiometric biosensors for direct determination of organophosphorus insecticides , 2000, Applied Microbiology and Biotechnology.

[5]  Kim R. Rogers,et al.  Acetylcholinesterase fiber-optic biosensor for detection of anticholinesterases. , 1991 .

[6]  W. Mulbry,et al.  Parathion hydrolase specified by the Flavobacterium opd gene: relationship between the gene and protein , 1989, Journal of bacteriology.

[7]  M. Mascini,et al.  Determination of anticholinesterase pesticides in real samples using a disposable biosensor , 1997 .

[8]  Ashok Mulchandani,et al.  Flow injection amperometric detection of OP nerve agents based on an organophosphorus-hydrolase biosensor detector. , 2003, Biosensors & bioelectronics.

[9]  A. A. Shul'ga,et al.  Conductometric biosensor for determination of organophosphorus pesticides , 1994 .

[10]  R Narayanaswamy,et al.  Fibre-optic pesticide biosensor based on covalently immobilized acetylcholinesterase and thymol blue. , 1997, Talanta: The International Journal of Pure and Applied Analytical Chemistry.

[11]  N. Verma,et al.  A disposable microbial based biosensor for quality control in milk. , 2003, Biosensors & bioelectronics.

[12]  K R Rogers,et al.  Biosensors for direct determination of organophosphate pesticides. , 2001, Biosensors & bioelectronics.

[13]  G. Robinson,et al.  Methods in biotechnology—immobilization of enzymes and cells; Edited by G F Bickerstaff. pp 367. Humana Press, New Jersey. 1996 ISBN 0‐89603‐386‐4 , 1997 .

[14]  S. F. D’souza,et al.  Immobilization and stabilization of biomaterials for biosensor applications , 2001, Applied biochemistry and biotechnology.

[15]  J. Wild,et al.  The development of a new biosensor based on recombinant E. coli for the direct detection of organophosphorus neurotoxins. , 1996, Biosensors & bioelectronics.

[16]  Ashok Mulchandani,et al.  Enzyme biosensor for determination of organophosphates , 1998 .

[17]  D. Munnecke,et al.  Microbial decontamination of parathion and p-nitrophenol in aqueous media. , 1974, Applied microbiology.

[18]  L. C. Luchini,et al.  Monitoring of pesticide residues in a cotton crop soil , 2000, Journal of environmental science and health. Part. B, Pesticides, food contaminants, and agricultural wastes.

[19]  K R Rogers,et al.  Acetylcholinesterase fiber-optic biosensor for detection of anticholinesterases. , 1991, Fundamental and applied toxicology : official journal of the Society of Toxicology.

[20]  A Mulchandani,et al.  Flow injection amperometric enzyme biosensor for direct determination of organophosphate nerve agents. , 2001, Environmental science & technology.

[21]  J. Švitel,et al.  Microbial cell-based biosensor for sensing glucose, sucrose or lactose. , 1998, Biotechnology and applied biochemistry.

[22]  G. S. Wilson,et al.  Biosensors : fundamentals and applications , 1987 .

[23]  Ashok Mulchandani,et al.  A Potentiometric Microbial Biosensor for Direct Determination of Organophosphate Nerve Agents , 1998 .

[24]  N. Ward,et al.  The Organophosphate Pesticides , 1995 .

[25]  A Mulchandani,et al.  Biosensor for direct determination of organophosphate nerve agents using recombinant Escherichia coli with surface-expressed organophosphorus hydrolase. 2. Fiber-optic microbial biosensor. , 1998, Analytical chemistry.

[26]  Ashok Mulchandani,et al.  Enzyme and microbial biosensors : techniques and protocols , 1998 .

[27]  S. F. D’souza,et al.  IMMOBILIZED ENZYMES IN BIOPROCESS , 1999 .

[28]  Ashok Mulchandani,et al.  Remote Biosensor for In-Situ Monitoring of Organophosphate Nerve Agents , 1999 .

[29]  A Mulchandani,et al.  Fiber‐Optic Enzyme Biosensor for Direct Determination of Organophosphate Nerve Agents , 1999, Biotechnology progress.

[30]  Ashok Mulchandani,et al.  Organophosphorus Hydrolase‐Based Amperometric Sensor: Modulation of Sensitivity and Substrate Selectivity , 2002 .

[31]  S. F. D’souza,et al.  Microbial biosensors. , 2001, Biosensors & bioelectronics.

[32]  W. Mulbry,et al.  Purification and characterization of three parathion hydrolases from gram-negative bacterial strains , 1989, Applied and environmental microbiology.

[33]  F. Raushel,et al.  Purification and properties of the phosphotriesterase from Pseudomonas diminuta. , 1989, The Journal of biological chemistry.

[34]  Gordon F. Bickerstaff Immobilization of Enzymes and Cells , 1996 .

[35]  A. Mulchandani,et al.  Organophosphorus Hydrolase‐Based Assay for Organophosphate Pesticides , 1999, Biotechnology progress.