Blood or Urine Glucose-Based Insulin Therapy and Control of Glycemia: Computer-Simulation Study

Adjustment algorithms for conventional insulin therapy must be tested for safety and efficacy before clinical implementation. We did this by computer simulation. Accordingly, a computer simulator of human intermediary metabolism created 10 randomly chosen diabetic subjects for study. All were well defined with respect to compliance (i.e., medication and diet) and life-style (i.e., physical and emotional stress). Insulinadjustment algorithms that were tested calculated daily insulin dosages for these computer-simulated patients based on either blood or urine glucose concentrations self-measured 4 times/day before breakfast, lunch, dinner, and bedtime snack. The twofold purpose of the simulation study was to determine the ability of the adjustment algorithms to improve initially poor metabolic control and to compare the outcomes when either blood or urine glucose measurements were the basis on which glycemic control was implemented. A significant improvement in metabolic control could be achieved with either blood or urine glucose measurements as input to the algorithms. Detailed comparisons between blood and urine glucose-based treatments showed no significant advantage of blood glucose-based algorithms at breakfast (122 ± 21 vs. 131 ± 16 mg/dl) and dinner (117 ± 27 vs. 130 ± 23 mg/dl), whereas mean glycemia at lunch (122 ± 24 vs. 164 ± 21 mg/dl) and bedtime (117 ± 25 vs. 150 ± 21 mg/dl) after 120 days of simulation did differ significantly (P < 0.01). Hypoglycemia was not provoked by either treatment. Total daily insulin doses evolved by blood glucose-based algorithms were significantly (P < 0.05) higher than the doses used by urine glucose-based algorithms (53 vs. 47 U). We conclude that either blood or urine glucose-based insulin-adjustment algorithms that we devised promise to achieve improved glycemic control with only minor differences between the two. Clinical studies can now safely be conducted.

[1]  H. Keen,et al.  “Instant” Blood Sugar Measurement Using Dextrostix and a Reflectance Meter , 1970, Diabetes.

[2]  W. Tamborlane,et al.  Reduction to normal of plasma glucose in juvenile diabetes by subcutaneous administration of insulin with a portable infusion pump. , 1979, The New England journal of medicine.

[3]  F. Nuttall Dietary recommendations for individuals with diabetes mellitus, 1979: summary of report from the Food and Nutrition Committee of the American Diabetes Association. , 1980, The American journal of clinical nutrition.

[4]  J. M. Brudenell,et al.  MANAGEMENT OF THE PREGNANT DIABETIC: HOME OR HOSPITAL, WITH OR WITHOUT GLUCOSE METERS? , 1980, The Lancet.

[5]  A. Schiffrin,et al.  Combined Continuous Subcutaneous Insulin Infusion and Multiple Subcutaneous Injections in Type I Diabetic Patients , 1981, Diabetes Care.

[6]  J. Skyler,et al.  Algorithms for Adjustment of Insulin Dosage by Patients Who Monitor Blood Glucose , 1981, Diabetes Care.

[7]  M. Rendell,et al.  The Dawn Phenomenon, an Early Morning Glucose Rise: Implications for Diabetic Intraday Blood Glucose Variation , 1981, Diabetes Care.

[8]  P. Brunetti,et al.  Continuous subcutaneous insulin infusion treatment in insulin-dependent diabetic patients: a comparison with conventional optimized treatment in a long-term study. , 1982, Diabetes care.

[9]  A. Schiffrin,et al.  Comparison Between Continuous Subcutaneous Insulin Infusion and Multiple Injections of Insulin: A One-Year Prospective Study , 1982, Diabetes.

[10]  K. Alberti,et al.  Intensive attention improves glycaemic control in insulin-dependent diabetes without further advantage from home blood glucose monitoring: results of a controlled trial. , 1982 .

[11]  G. Grodsky,et al.  Reduced Solubility of Short-Acting Soluble Insulins when Mixed with Longer-Acting Insulins , 1983, Diabetes.

[12]  A. Schiffrin,et al.  Evaluation of Two Methods of Self Blood Glucose Monitoring by Trained Insulin-dependent Diabetic Adolescents Outside the Hospital , 1983, Diabetes Care.

[13]  W. Bablok,et al.  Evaluation of Diabur-Test 5000: A Cooperative Study Carried Out at 12 Diabetes Centers , 1983, Diabetes Care.

[14]  R. Rizza,et al.  Prandial insulin requirements in insulin-dependent diabetics: effects of size, time of day, and sequence of meals. , 1983, The Journal of clinical endocrinology and metabolism.

[15]  N. White,et al.  Relative Roles of Insulin Clearance and Insulin Sensitivity in the Prebreakfast Increase in Insulin Requirements in Insulin-dependent Diabetic Patients , 1984, Diabetes.

[16]  A. Schiffrin,et al.  Computer-assisted Insulin Dosage Adjustment , 1985, Diabetes Care.

[17]  G. Gillett CLINICAL BIOCHEMISTRY NEARER THE PATIENT II , 1986, The Lancet.

[18]  A M Albisser,et al.  Compliance in microcomputer-assisted conventional insulin therapy: computer simulation study results. , 1988, The American journal of physiology.

[19]  A. Albisser Intelligent instrumentation in diabetic management. , 1989, Critical reviews in biomedical engineering.

[20]  A. M. Albisser,et al.  Insulin dosage adjustment using manual methods and computer algorithms: A comparative study , 2006, Medical and Biological Engineering and Computing.