Neutronics analysis for the ITER core imaging X-ray spectrometer

Abstract This paper presents new results of the MCNP neutronics analysis for the core imaging X-ray spectrometer (CIXS) system of the ITER Equatorial Port Plug #17 (EPP#17). Substantial radiation shielding design improvements of the CIXS system have been suggested as the outcomes of this analysis. These suggested improvements allow reaching two major goals: (1) radiation protection of the CIXS Port Interspace (PI) to provide personnel access for maintenance of the vacuum extension flange; (2) reduction of the neutron and gamma loads on the detectors to reduce the need for maintenance itself. By implementing the improvements in our models such as filling void spaces around the CIXS beams with boron carbide and inserting the tungsten collimators in the narrowed beam channel, we were able to reduce the Shut-Down Dose Rate (SDDR) in the PI by 100× from 2 mSv/h in the original CIXS design to 20 microSv/h. In case of non-changed MCNP geometry, the D1S method was applied in calculations of SDDR. To allow the maintenance access to the flange, a part of shielding was removed, therefore the R2Smesh methodology was applied instead of D1S. During the maintenance access of CIXS from the PI side, a screen plate was proposed to introduce behind which a worker receives much less SDDR.

[1]  Victor Udintsev,et al.  Shut-Down Dose Rate analysis for ITER Diagnostic Equatorial and Upper Ports , 2014 .

[2]  Hiromasa Iida,et al.  Proposal of shutdown dose estimation method by Monte Carlo code , 2001 .

[3]  B. Levesy,et al.  Shutdown dose rates at ITER equatorial ports considering radiation cross-talk from torus cryopump lower port , 2015 .

[4]  Rosaria Villari,et al.  Novel approach for efficient mesh based Monte Carlo shutdown dose rate calculations , 2013 .

[5]  Victor Udintsev,et al.  Neutronic analysis of the Diagnostic Equatorial Ports in ITER , 2015 .

[6]  Victor Udintsev,et al.  Final design of the generic upper port plug structure for ITER diagnostic systems , 2015 .

[7]  Yican Wu,et al.  CAD-based interface programs for fusion neutron transport simulation , 2009 .

[8]  Rosaria Villari,et al.  Shutdown dose rate assessment with the Advanced D1S method: Development, applications and validation , 2014 .

[9]  J. F. Briesmeister MCNP-A General Monte Carlo N-Particle Transport Code , 1993 .

[10]  M. A. Henderson,et al.  Neutronics for equatorial and upper ports in ITER , 2013 .

[11]  R. A. Forrest,et al.  FISPACT-2007: User manual , 2007 .

[12]  Arkady Serikov,et al.  Status of the McCad geometry conversion tool and related visualization capabilities for 3D fusion neutronics calculations , 2013 .

[13]  Arkady Serikov,et al.  Monte Carlo radiation shielding and activation analyses for the Diagnostic Equatorial Port Plug in ITER , 2012 .

[14]  D. J. Brenner Conversion Coefficients for Use in Radiological Protection against External Radiation , 1999 .