Automation of static and dynamic non-dispersive liquid phase microextraction. Part 1: Approaches based on extractant drop-, plug-, film- and microflow-formation.

Simplicity, effectiveness, swiftness, and environmental friendliness - these are the typical requirements for the state of the art development of green analytical techniques. Liquid phase microextraction (LPME) stands for a family of elegant sample pretreatment and analyte preconcentration techniques preserving these principles in numerous applications. By using only fractions of solvent and sample compared to classical liquid-liquid extraction, the extraction kinetics, the preconcentration factor, and the cost efficiency can be increased. Moreover, significant improvements can be made by automation, which is still a hot topic in analytical chemistry. This review surveys comprehensively and in two parts the developments of automation of non-dispersive LPME methodologies performed in static and dynamic modes. Their advantages and limitations and the reported analytical performances are discussed and put into perspective with the corresponding manual procedures. The automation strategies, techniques, and their operation advantages as well as their potentials are further described and discussed. In this first part, an introduction to LPME and their static and dynamic operation modes as well as their automation methodologies is given. The LPME techniques are classified according to the different approaches of protection of the extraction solvent using either a tip-like (needle/tube/rod) support (drop-based approaches), a wall support (film-based approaches), or microfluidic devices. In the second part, the LPME techniques based on porous supports for the extraction solvent such as membranes and porous media are overviewed. An outlook on future demands and perspectives in this promising area of analytical chemistry is finally given.

[1]  F. Borrull,et al.  Fully automated ionic liquid-based headspace single drop microextraction coupled to GC-MS/MS to determine musk fragrances in environmental water samples. , 2012, Talanta.

[2]  M. Miró,et al.  On-line sample processing involving microextraction techniques as a front-end to atomic spectrometric detection for trace metal assays: a review. , 2013, Analytica chimica acta.

[3]  P. Solich,et al.  Automated in-syringe single-drop head-space micro-extraction applied to the determination of ethanol in wine samples. , 2014, Analytica chimica acta.

[4]  G. Christian,et al.  Sequential injection wetting film extraction applied to the spectrophotometric determination of chromium(VI) and chromium(III) in water. , 1997, Talanta.

[5]  M. Saraji Dynamic headspace liquid-phase microextraction of alcohols. , 2005, Journal of chromatography. A.

[6]  A. Anthemidis,et al.  On-line liquid phase micro-extraction based on drop-in-plug sequential injection lab-at-valve platform for metal determination. , 2013, Analytica chimica acta.

[7]  Takehiko Kitamori,et al.  DISTRIBUTION OF METHYL RED ON THE WATER–ORGANIC LIQUID INTERFACE IN A MICROCHANNEL , 2001 .

[8]  Takehiko Kitamori,et al.  On-Chip Integration of Neutral Ionophore-Based Ion Pair Extraction Reaction , 2001 .

[9]  Hossein Salimi-Moosavi,et al.  Electroosmotic Pumping of Organic Solvents and Reagents in Microfabricated Reactor Chips , 1997 .

[10]  Dai Youyuan,et al.  Directly suspended droplet microextraction , 2006 .

[11]  B. Reis,et al.  Solvent extraction in continuous flow injection analysis , 1978 .

[12]  C. Lucy,et al.  Mechanism of extraction and band broadening in solvent extraction-flow injection analysis , 1989 .

[13]  Hian Kee Lee,et al.  Liquid-phase microextraction combined with hollow fiber as a sample preparation technique prior to gas chromatography/mass spectrometry. , 2002, Analytical chemistry.

[14]  M. Á. González-Curbelo,et al.  Liquid phase microextraction applications in food analysis. , 2011, Journal of chromatography. A.

[15]  Emmanuel Delamarche,et al.  Lab-on-a-chip devices , 2015 .

[16]  A. Przyjazny,et al.  Single drop microextraction--development, applications and future trends. , 2010, Journal of chromatography. A.

[17]  E. Stanisz,et al.  Liquid-phase microextraction techniques based on ionic liquids for preconcentration and determination of metals , 2014 .

[18]  Víctor Cerdà,et al.  Automated in-syringe dispersive liquid-liquid microextraction , 2014 .

[19]  Tatsuo Maruyama,et al.  Liquid membrane operations in a microfluidic device for selective separation of metal ions. , 2004, Analytical chemistry.

[20]  K. Yeung,et al.  Solvent extraction-flow injection without phase separation through the use of the differential flow velocities within the segmented flow , 1994 .

[21]  T. Khayamian,et al.  Determination of volatile residual solvents in pharmaceutical products by static and dynamic headspace liquid-phase microextraction combined with gas chromatography-flame ionization detection , 2012 .

[22]  Andrzej Przyjazny,et al.  Solvent Microextraction: Theory and Practice , 2009 .

[23]  F. Cantwell,et al.  Mass Transfer Characteristics of Solvent Extraction into a Single Drop at the Tip of a Syringe Needle , 1997 .

[24]  F. R. Rocha,et al.  Liquid-liquid microextraction in a multicommuted flow system for direct spectrophotometric determination of iodine value in biodiesel. , 2014, Analytica chimica acta.

[25]  J. Pawliszyn,et al.  Kinetic calibration for automated hollow fiber-protected liquid-phase microextraction. , 2006, Analytical chemistry.

[26]  C. Lucy,et al.  Flow injection preconcentration using differential flow velocities in two-phase segmented flow , 1995 .

[27]  Víctor Cerdà,et al.  Lab in a syringe: fully automated dispersive liquid–liquid microextraction with integrated spectrophotometric detection , 2012, Analytical and Bioanalytical Chemistry.

[28]  J. V. van Staden,et al.  Determination of Lead(II), Copper(II), Zinc(II), Cobalt(II), Cadmium(II), Iron(III), Mercury(II) using sequential injection extractions. , 2004, Talanta.

[29]  Y. Wang,et al.  Application of dynamic liquid-phase microextraction to the analysis of chlorobenzenes in water by using a conventional microsyringe. , 1998, Analytical chemistry.

[30]  Purnendu K. Dasgupta,et al.  Liquid Droplet. A Renewable Gas Sampling Interface , 1995 .

[31]  F. Pena-Pereira,et al.  Liquid-phase microextraction techniques within the framework of green chemistry , 2010 .

[32]  V. Ponnusamy,et al.  Determination of ammonium in aqueous samples using new headspace dynamic in-syringe liquid-phase microextraction with in situ derivitazation coupled with liquid chromatography-fluorescence detection. , 2012, Analytica chimica acta.

[33]  Marcin Wieczorek,et al.  An automatic, vigorous-injection assisted dispersive liquid-liquid microextraction technique for stopped-flow spectrophotometric detection of boron. , 2015, Talanta.

[34]  C. Lucy,et al.  Co-current chromatography: A new mode of liquid-liquid chromatography , 1995 .

[35]  Y. Yamini,et al.  Developments in hollow fiber based liquid-phase microextraction: principles and applications , 2012, Microchimica Acta.

[36]  Hian Kee Lee,et al.  Continuous flow microextraction combined with high-performance liquid chromatography for the analysis of pesticides in natural waters. , 2006, Journal of chromatography. A.

[37]  S. Cox,et al.  Automated dynamic headspace organic solvent film microextraction for benzene , toluene , ethylbenzene and xylene : Renewable liquid film as a sampler by a programmable motor , 2006 .

[38]  A. Anthemidis,et al.  Development of on-line single-drop micro-extraction sequential injection system for electrothermal atomic absorption spectrometric determination of trace metals. , 2009, Analytica chimica acta.

[39]  Takehiko Kitamori,et al.  Continuous-flow chemical processing on a microchip by combining microunit operations and a multiphase flow network. , 2002, Analytical chemistry.

[40]  Shuang Hu,et al.  Applications of liquid-phase microextraction techniques in natural product analysis: a review. , 2014, Journal of chromatography. A.

[41]  M. Miró,et al.  Multicomponent sequential injection analysis determination of nitro-phenols in waters by on-line liquid-liquid extraction and preconcentration , 2000 .

[42]  B. Karlberg,et al.  Flow Injection Analysis: A Practical Guide , 1989 .

[43]  Archana Jain,et al.  Recent advances in applications of single-drop microextraction: a review. , 2011, Analytica chimica acta.

[44]  M. Miró,et al.  Sequential injection 90Sr determination in environmental samples using a wetting-film extraction method. , 2002, Analytical chemistry.

[45]  Hian Kee Lee,et al.  Fully automated dynamic in-syringe liquid-phase microextraction and on-column derivatization of carbamate pesticides with gas chromatography/mass spectrometric analysis. , 2011, Analytical chemistry.

[46]  G. Christian,et al.  Sequential Injection Photometric Determination of Molybdenum Using Organic Wetting Film Extraction , 1997 .

[47]  M. Valcárcel,et al.  Ionic liquid-based dynamic liquid-phase microextraction: application to the determination of anti-inflammatory drugs in urine samples. , 2008, Journal of chromatography. A.

[48]  V. Wallace Rapid automated analysis involving liquid-liquid extraction: atropine by a Prudhomme method. , 1967, Analytical biochemistry.

[49]  K Uchiyama,et al.  Integrated Multilayer Flow System on a Microchip , 2001, Analytical sciences : the international journal of the Japan Society for Analytical Chemistry.

[50]  I. Lavilla,et al.  Immersed single-drop microextraction interfaced with sequential injection analysis for determination of Cr(VI) in natural waters by electrothermal-atomic absorption spectrometry , 2008 .

[51]  P. Dasgupta,et al.  Analytical chemistry in a drop , 1996 .

[52]  G. Christian,et al.  Solvent extraction–sequential injection without segmentation and phase separation based on the wetting film formed on a Teflon tube wall , 1996 .

[53]  Seyed Ali Mousavi Shaegh,et al.  Microfluidics for Advanced Drug Delivery Systems , 2015, Current opinion in chemical engineering.

[54]  Q. Fang,et al.  Analytical detection techniques for droplet microfluidics--a review. , 2013, Analytica chimica acta.

[55]  L. Mathiasson,et al.  Sample preparation using a miniaturized supported liquid membrane device connected on-line to packed capillary liquid chromatography. , 1996, Analytical chemistry.

[56]  Víctor Cerdà,et al.  Completely automated in-syringe dispersive liquid–liquid microextraction using solvents lighter than water , 2011, Analytical and Bioanalytical Chemistry.

[57]  Takehiko Kitamori,et al.  Molecular Transport between Two Phases in a Microchannel , 2000 .

[58]  Purnendu K. Dasgupta,et al.  A liquid drop: A windowless optical cell and a reactor without walls for flow injection analysis , 1996 .

[59]  J. Ruzicka,et al.  Sequential injection: a new concept for chemical sensors, process analysis and laboratory assays , 1990 .

[60]  J. Pawliszyn,et al.  Automation and optimization of liquid-phase microextraction by gas chromatography. , 2007, Journal of chromatography. A.

[61]  Łukasz Marcinkowski,et al.  Green aspects, developments and perspectives of liquid phase microextraction techniques. , 2014, Talanta.

[62]  A. Anthemidis,et al.  An automatic countercurrent liquid-liquid micro-extraction system coupled with atomic absorption spectrometry for metal determination. , 2015, Talanta.

[63]  F. R. Rocha,et al.  A multicommuted flow system with liquid–liquid microextraction for determination of anionic surfactants in freshwaters , 2013 .

[64]  Víctor Cerdà,et al.  In-syringe magnetic stirring assisted dispersive liquid–liquid micro-extraction with solvent washing for fully automated determination of cationic surfactants , 2014 .

[65]  Tiangang Luan,et al.  Fully automatic exposed and in-syringe dynamic single-drop microextraction with online agitation for the determination of polycyclic musks in surface waters of the Pearl River Estuary and South China Sea. , 2014, Journal of separation science.

[66]  Gorjan Alagic,et al.  #p , 2019, Quantum information & computation.

[67]  M. Miró,et al.  Dual wetting-film multi-syringe flow injection analysis extraction: Application to the simultaneous determination of nitrophenols , 2001 .

[68]  Hian Kee Lee,et al.  Dynamic three-phase microextraction as a sample preparation technique prior to capillary electrophoresis. , 2003, Analytical chemistry.

[69]  Leonid Moskvin,et al.  Stepwise injection analysis as a new method of flow analysis , 2007 .

[70]  Michal Alexovič,et al.  Automatic determination of copper by in-syringe dispersive liquid-liquid microextraction of its bathocuproine-complex using long path-length spectrophotometric detection. , 2012, Talanta.

[71]  Alex Terray,et al.  On-line sample pre-concentration in microfluidic devices: a review. , 2012, Analytica chimica acta.

[72]  Víctor Cerdà,et al.  A robust multisyringe system for process flow analysis. Part I. On-line dilution and single point titration of protolytes , 1999 .

[73]  P. Rohr,et al.  Liquid Extraction of Vanillin in Rectangular Microreactors , 2008 .

[74]  J. Kokosa Advances in solvent-microextraction techniques , 2013 .

[75]  A. Anthemidis,et al.  Flow injection wetting-film extraction system for flame atomic absorption spectrometric determination of cadmium in environmental waters. , 2009, Talanta.

[76]  Francisco Pena-Pereira,et al.  Miniaturized preconcentration methods based on liquid–liquid extraction and their application in inorganic ultratrace analysis and speciation: A review , 2009 .

[77]  J. Berg,et al.  Vertically stratified flows in microchannels. Computational simulations and applications to solvent extraction and ion exchange. , 2003, Analytical chemistry.

[78]  Kihwan Choi,et al.  Single drop microextraction using commercial capillary electrophoresis instruments. , 2009, Analytical chemistry.

[79]  Jihye Kim,et al.  Headspace‐single drop microextraction with a commercial capillary electrophoresis instrument , 2012, Electrophoresis.

[80]  Yi He Recent advances in application of liquid-based micro-extraction: A review , 2014, Chemical Papers.

[81]  C. Pasquini,et al.  Effect of ethanol in the organic phase on liquid-liquid extraction in monosegmented flow analysis. Determination of zinc in drugs. , 2002, Talanta.

[82]  Nicolas Kalogerakis,et al.  Developments in liquid-phase microextraction , 2003 .

[83]  Mohammad Saraji,et al.  Recent developments in dispersive liquid–liquid microextraction , 2014, Analytical and Bioanalytical Chemistry.

[84]  T Kitamori,et al.  Integration of a microextraction system solvent extraction of a Co-2-nitroso-5-dimethylaminophenol complex on a microchip. , 2000, Journal of chromatography. A.

[85]  C. Pasquini,et al.  An automated system for liquid-liquid extraction in monosegmented flow analysis , 1997, The Journal of automatic chemistry.

[86]  Daniel T Chiu,et al.  Disposable microfluidic devices: fabrication, function, and application. , 2005, BioTechniques.

[87]  Takehiko Kitamori,et al.  Stabilization of liquid interface and control of two-phase confluence and separation in glass microchips by utilizing octadecylsilane modification of microchannels. , 2002, Analytical chemistry.

[88]  Taisuke Maki,et al.  Liquid–liquid extraction for efficient synthesis and separation by utilizing micro spaces , 2008 .

[89]  Zhao-Lun Fang,et al.  A microfluidic chip based sequential injection system with trapped droplet liquid-liquid extraction and chemiluminescence detection. , 2006, Lab on a chip.

[90]  N. R. Kuzel Automated analysis of tertiary amines. , 1968, Journal of pharmaceutical sciences.

[91]  Heng-wu Chen,et al.  A gravity driven micro flow injection wetting film extraction system on a polycarbonate chip. , 2006, Talanta.

[92]  Marek Trojanowicz,et al.  Flow Injection Analysis: Instrumentation and Applications , 2000 .

[93]  M. Rezaee,et al.  Determination of organic compounds in water using dispersive liquid-liquid microextraction. , 2006, Journal of chromatography. A.

[94]  Meng Sun,et al.  Microfluidic liquid-liquid extraction system based on stopped-flow technique and liquid core waveguide capillary. , 2006, Talanta.

[95]  Catherine A. Rivet,et al.  Microfluidics for medical diagnostics and biosensors , 2011 .

[96]  Jaromir Růžička,et al.  Flow injection analysis , 1981 .

[97]  G. Christian,et al.  Sequential-injection extraction for sample preparation , 1997 .

[98]  Clarisse Mariet,et al.  Microfluidic Tools for the Liquid-liquid Extraction of Radionuclides in Analytical Procedures , 2012 .

[99]  Víctor Cerdà,et al.  In-syringe magnetic-stirring-assisted liquid–liquid microextraction for the spectrophotometric determination of Cr(VI) in waters , 2013, Analytical and Bioanalytical Chemistry.

[100]  G. Audunsson,et al.  Aqueous/aqueous extraction by means of a liquid membrane for sample cleanup and preconcentration of amines in a flow system , 1986 .

[101]  Liu,et al.  Continuous-flow microextraction exceeding 1000-fold concentration of dilute analytes , 2000, Analytical chemistry.

[102]  F. R. Rocha,et al.  Liquid-liquid microextraction without phase separation in a multicommuted flow system for diltiazem determination in pharmaceuticals. , 2011, Analytica chimica acta.

[103]  J. Pawliszyn,et al.  Kinetic calibration for automated headspace liquid-phase microextraction. , 2005, Analytical chemistry.

[104]  Masahiro Chiba,et al.  Spatially-Resolved Fluorescence Spectroscopic Study on Liquid/Liquid Extraction Processes in Polymer Microchannels , 2000 .

[105]  J. Kokosa Recent trends in using single-drop microextraction and related techniques in green analytical methods , 2015 .

[106]  B. Karlberg,et al.  Extraction based on the flow-injection principle , 1980 .

[107]  P. K. Dasgupta,et al.  A membraneless gas diffusion unit: design and its application to determination of ethanol in liquors by spectrophotometric flow injection. , 2006, Analytica chimica acta.

[108]  Baizhan Liu,et al.  Development of solvent micro-extraction combined with derivatization. , 2013, Journal of chromatography. A.

[109]  Chun-Xia Zhao,et al.  Multiphase flow microfluidics for the production of single or multiple emulsions for drug delivery. , 2013, Advanced drug delivery reviews.

[110]  V. Cerdà,et al.  An Introduction to Laboratory Automation , 1991 .

[111]  Michael G. Roper,et al.  Microfluidics-to-mass spectrometry: a review of coupling methods and applications. , 2015, Journal of chromatography. A.

[112]  S. Pedersen‐Bjergaard,et al.  Liquid-liquid-liquid microextraction for sample preparation of biological fluids prior to capillary electrophoresis. , 1999, Analytical chemistry.

[113]  M Valcárcel,et al.  Determination of phenothiazine derivatives in human urine by using ionic liquid-based dynamic liquid-phase microextraction coupled with liquid chromatography. , 2009, Journal of chromatography. B, Analytical technologies in the biomedical and life sciences.

[114]  Stephen C. Jacobson,et al.  Open channel electrochromatography on a microchip , 1994 .

[115]  Zhao-Lun Fang,et al.  Microfluidic chip-based liquid-liquid extraction and preconcentration using a subnanoliter-droplet trapping technique. , 2005, Lab on a chip.

[116]  Heng-wu Chen,et al.  Coupling of flow injection wetting-film extraction without segmentation and phase separation to flame atomic absorption spectrometry for the determination of trace copper in water samples , 1998 .

[117]  B. Karlberg,et al.  Extraction based on the flow-injection principle : Part I. Description of the Extraction System , 1978 .

[118]  Yuanying Chen,et al.  Rapid evolution of piRNA clusters in the Drosophila melanogaster ovary , 2023, bioRxiv.

[119]  Bo Karlberg,et al.  Flow Injection Analysis , 1982 .

[120]  Polona Žnidaršič-Plazl,et al.  Ionic liquid-based aqueous two-phase extraction within a microchannel system , 2012 .

[121]  Á. Ríos,et al.  Modern qualitative analysis by miniaturized and microfluidic systems , 2015 .

[122]  Zhihong Shi,et al.  Progress of Extraction Solvent Dispersion Strategies for Dispersive Liquid-liquid Microextraction , 2015 .

[123]  Jeonghoon Lee,et al.  Microfluidics with MALDI analysis for proteomics--a review. , 2009, Analytica chimica acta.

[124]  G. Khayatian,et al.  Continuous sample drop flow-based microextraction method as a microextraction technique for determination of organic compounds in water sample. , 2014, Talanta.

[125]  S. Myung,et al.  Analysis of benzene ethylamine derivatives in urine using the programmable dynamic liquid-phase microextraction (LPME) device. , 2003, The Analyst.

[126]  N. Kalogerakis,et al.  Developments in single-drop microextraction , 2002 .

[127]  Amirhassan Amiri,et al.  Liquid-phase microextraction , 2010 .

[128]  Yuan Zhang,et al.  Chip-based liquid phase microextraction combined with electrothermal vaporization-inductively coupled plasma mass spectrometry for trace metal determination in cell samples , 2013 .

[129]  J. Namieśnik,et al.  Opportunities and shortcomings of ionic liquids in single-drop microextraction , 2015 .

[130]  Gangfeng Ouyang,et al.  Comparison of fully-automated headspace single drop microextraction and headspace solid phase microextraction techniques for rapid analysis of No. 6 solvent residues in edible oil , 2014 .

[131]  C. Pasquini,et al.  Single-phase liquid-liquid extraction in monosegmented continuous-flow systems , 1994 .

[132]  Robert W. Lewis,et al.  Thiolene and SIFEL-based Microfluidic Platforms for Liquid-Liquid Extraction. , 2014, Sensors and actuators. B, Chemical.

[133]  I. Timofeeva,et al.  Automated procedure for determination of ammonia in concrete with headspace single-drop micro-extraction by stepwise injection spectrophotometric analysis. , 2015, Talanta.

[134]  J. Lima,et al.  Multi-pumping in flow analysis: concepts, instrumentation, potentialities , 2002 .

[135]  Bifeng Liu,et al.  Rapid, highly efficient extraction and purification of membrane proteins using a microfluidic continuous-flow based aqueous two-phase system. , 2011, Journal of chromatography. A.

[136]  A. Anthemidis,et al.  Automated headspace single-drop microextraction via a lab-in-syringe platform for mercury electrothermal atomic absorption spectrometric determination after in situ vapor generation , 2014 .

[137]  T Kitamori,et al.  Integration of a wet analysis system on a glass chip: determination of Co(ii) as 2-nitroso-1-naphthol chelates by solvent extraction and thermal lens microscopy. , 2001, Lab on a chip.

[138]  F. Borrull,et al.  Determination of musk fragrances in sewage sludge by pressurized liquid extraction coupled to automated ionic liquid-based headspace single-drop microextraction followed by GC-MS/MS. , 2012, Journal of separation science.

[139]  A. Voulgaropoulos,et al.  Automated sample treatment by flow techniques prior to liquid-phase separations. , 2007, Journal of biochemical and biophysical methods.

[140]  Takehiko Kitamori,et al.  Microfluidic extraction of copper from particle-laden solutions , 2011 .

[141]  M. Tokeshi,et al.  Integration of a microextraction system on a glass chip: ion-pair solvent extraction of Fe(II) with 4,7-diphenyl-1,10-phenanthrolinedisulfonic acid and tri-n-octylmethylammonium chloride , 2000, Analytical chemistry.

[142]  M. He,et al.  Liquid phase microextraction for the analysis of trace elements and their speciation , 2013 .

[143]  J. Ruzicka,et al.  Flow injection analyses , 1975 .

[144]  Víctor Cerdà,et al.  In-syringe-stirring: a novel approach for magnetic stirring-assisted dispersive liquid-liquid microextraction. , 2013, Analytica chimica acta.

[145]  M. Miró,et al.  Recent Developments in Flow Injection/Sequential Injection Liquid-Liquid Extraction for Atomic Spectrometric Determination of Metals and Metalloids , 2009 .

[146]  Takehiko Kitamori,et al.  Integration of Flow Injection Analysis and Zeptomole-Level Detection of the Fe(II)-o-Phenanthroline Complex , 1999 .

[147]  M. Jeannot,et al.  Solvent microextraction into a single drop. , 1996, Analytical chemistry.

[148]  V. Andruch,et al.  Solvent microextraction: A review of recent efforts at automation , 2013 .

[149]  I. Lavilla,et al.  Nanoparticle-enhanced liquid-phase microextraction , 2015 .

[150]  C. Basheer,et al.  Developments in single-drop microextraction. , 2007, Journal of chromatography. A.

[151]  Hian Kee Lee,et al.  Liquid-Phase Microextraction in a Single Drop of Organic Solvent by Using a Conventional Microsyringe , 1997 .

[152]  G. G. Stokes "J." , 1890, The New Yale Book of Quotations.

[153]  Clarisse Mariet,et al.  Liquid-liquid extraction of uranium(VI) with Aliquat® 336 from HCl media in microfluidic devices: Combination of micro-unit operations and online ICP-MS determination. , 2015, Talanta.

[154]  Takehiko Kitamori,et al.  Microchip-based liquid-liquid extraction for gas-chromatography analysis of amphetamine-type stimulants in urine. , 2006, Journal of chromatography. A.

[155]  R. Zengerle,et al.  Microfluidic lab-on-a-chip platforms: requirements, characteristics and applications. , 2010, Chemical Society reviews.

[156]  M. Jeannot,et al.  Headspace solvent microextraction. , 2001, Analytical chemistry.

[157]  A. Manz,et al.  Miniaturized total chemical analysis systems: A novel concept for chemical sensing , 1990 .

[158]  K Uchiyama,et al.  On-chip integration of sequential ion-sensing system based on intermittent reagent pumping and formation of two-layer flow. , 2001, Analytical chemistry.

[159]  M. Miró,et al.  Hybrid flow analyzer for automatic hollow-fiber-assisted ionic liquid-based liquid-phase microextraction with in-line membrane regeneration , 2013, Analytical and Bioanalytical Chemistry.

[160]  Purnendu K. Dasgupta,et al.  A Renewable Liquid Droplet as a Sampler and a Windowless Optical Cell. Automated Sensor for Gaseous Chlorine , 1995 .

[161]  J. Lima,et al.  Liquid-liquid extraction in flow analysis: A critical review. , 2009, Analytica chimica acta.

[162]  H. Qiu,et al.  On-line coupling of ionic liquid-based single-drop microextraction with capillary electrophoresis for sensitive detection of phenols. , 2010, Journal of chromatography. A.

[163]  Q. Fang,et al.  Improved microfluidic chip-based sequential-injection trapped-droplet array liquid-liquid extraction system for determination of aluminium. , 2008, Talanta.

[164]  D. J. Harrison,et al.  Micromachining a Miniaturized Capillary Electrophoresis-Based Chemical Analysis System on a Chip , 1993, Science.

[165]  J. Lima,et al.  Multicommutation in flow analysis. Part 1. Binary sampling: concepts, instrumentation and spectrophotometric determination of iron in plant digests , 1994 .

[166]  Wenhua Gao,et al.  Trace analysis of three antihistamines in human urine by on-line single drop liquid-liquid-liquid microextraction coupled to sweeping micellar electrokinetic chromatography and its application to pharmacokinetic study. , 2012, Journal of chromatography. B, Analytical technologies in the biomedical and life sciences.

[167]  P. Dasgupta,et al.  Analytical chemistry in a drop. Solvent extraction in a microdrop. , 1996, Analytical chemistry.

[168]  Yooli K Light,et al.  Rapid, continuous purification of proteins in a microfluidic device using genetically-engineered partition tags. , 2008, Lab on a chip.

[169]  F. Shemirani,et al.  An overview of liquid phase microextraction approaches combined with UV-Vis spectrophotometry. , 2012, Talanta.

[170]  Yongseong Kim,et al.  Liquid-phase microextraction as an on-line preconcentration method in capillary electrophoresis. , 2004, Analytical chemistry.

[171]  L. Moskvin,et al.  Fully automated on-line flow-batch based ultrasound-assisted surfactant-mediated extraction and determination of anthraquinones in medicinal plants , 2014 .

[172]  Toru Futami,et al.  Enzymatic degradation of p-chlorophenol in a two-phase flow microchannel system. , 2003, Lab on a chip.

[173]  T. Albanis,et al.  Liquid-phase micro-extraction techniques in pesticide residue analysis. , 2007, Journal of biochemical and biophysical methods.

[174]  Hian Kee Lee,et al.  Application of static and dynamic liquid-phase microextraction in the determination of polycyclic aromatic hydrocarbons. , 2002, Journal of chromatography. A.

[175]  D. Peroni,et al.  Advancing liquid/liquid extraction through a novel microfluidic device: theory, instrumentation and applications in gas chromatography. , 2012, Journal of chromatography. A.