Smoke filling time for a room due to a small fire: The effect of ceiling height to floor width aspect ratio

Abstract We consider the filling of a room with smoke from a small, centrally located floor fire. We present theoretical arguments for the behaviour of the filling time relative to the idealised ‘filling box time’ [Baines WD, Turner JS. Turbulent buoyant convection from a source in a confined region. J Fluid Mech 1969;37:51–80] as a function of the room height to width aspect ratio. Initially, the rate at which the smoke layer deepens is shown to be more rapid for relatively wide rooms (large aspect ratio). However, at larger times, relatively tall rooms (small aspect ratio) fill more rapidly due to large scale overturning and engulfing of ambient fluid. A series of experiments were performed to verify these results and showed good qualitative agreement with our theoretical predictions. The experiments were also used to evaluate the extent of deviation of the actual smoke front position from the idealised filling box model as a function of the aspect ratio.

[1]  J. Turner,et al.  Turbulent entrainment: the development of the entrainment assumption, and its application to geophysical flows , 1986, Journal of Fluid Mechanics.

[2]  Rex Britter,et al.  The spread of a negatively buoyant plume in a calm environment , 1979 .

[3]  Wan Ki Chow,et al.  Experimental studies on natural smoke filling in atrium due to a shop fire , 2005 .

[4]  J. Turner,et al.  Turbulent buoyant convection from a source in a confined region , 1969, Journal of Fluid Mechanics.

[5]  G. Batchelor,et al.  Heat convection and buoyancy effects in fluids , 1954 .

[6]  Frederick W. Mowrer Enclosure Smoke Filling and Management with Mechanical Ventilation , 2002 .

[7]  Yogesh Jaluria,et al.  Effect of opposing buoyancy on the flow in free and wall jets , 1986, Journal of Fluid Mechanics.

[8]  G. Hunt,et al.  Overturning in a filling box , 2007, Journal of Fluid Mechanics.

[9]  S. J. Barnett The dynamics of buoyant releases in confined spaces , 1992 .

[10]  Leonard Y. Cooper Ceiling Jet-Driven Wall Flows in Compartment Fires , 1987 .

[11]  Gary R. Hunt,et al.  Virtual origin correction for lazy turbulent plumes , 2001, Journal of Fluid Mechanics.

[12]  Gary R. Hunt,et al.  Time-dependent flows in an emptying filling box , 2004, Journal of Fluid Mechanics.

[13]  Andrew W. Woods,et al.  The mixing in a room by a localized finite-mass-flux source of buoyancy , 2002, Journal of Fluid Mechanics.

[14]  Frederick W. Mowrer,et al.  Enclosure smoke filling revisited , 1999 .