Application of ultrasonic pulse-echo method to insulation condition diagnosis for large generators

It is a challenge to diagnose insulation condition of stator bars using an ultrasonic technique, due to the complex structures of the stator bars and the high attenuation of the stator insulation. In this paper, five low frequency transducers were used in a pulse-echo configuration to try to test a standby stator bar of a generator (300 MW, 18 kV). With an available transducer, four types of insulation structures were tested on the stator bar. The short side insulation was compared with the large one of the stator bar in the slot. The stator bar near the exit from the slot and the end stator bar, were compared with the stator bar in the slot. The semiconductive coating covered stator insulation was compared with the uncoated one. The stator insulation having an insulation-copper interface was compared with that having an insulation-gas interface. In addition, insulation diagnosis tests in the laboratory were performed on two sets of stator bars, which had been in service for 18 and 23 years, respectively in two generators (300 MW, 18 kV). Field tests were performed on the stator bars near the exit from the slot and the end stator bars of a generator (300 MW, 18 kV). The experimental results demonstrated an availability of low frequency ultrasonic pulse-echo method for insulation condition diagnosis of large generators

[1]  Hengkun Xie Ageing extent assessment of large generator insulation using advanced characterization techniques , 2001, Proceedings of 2001 International Symposium on Electrical Insulating Materials (ISEIM 2001). 2001 Asian Conference on Electrical Insulating Diagnosis (ACEID 2001). 33rd Symposium on Electrical and Ele.

[2]  Robert J. Ross,et al.  Analysis of in-service aged stator bars , 1995 .

[3]  J. E. Timperley,et al.  Acoustic spectrum analysis of high voltage mica based insulation systems , 1995, Proceedings:Electrical Electronics Insulation Conference and Electrical Manufacturing & Coil Winding Conference.

[4]  Hengkun Xie,et al.  Assessment of insulation condition of generator stator bars based on velocity of ultrasonic waves , 2003 .

[5]  Yoshiharu Kaneda,et al.  The role of microscopic defects in multistress aging of micaceous insulation , 1995 .

[6]  J. K. Nelson,et al.  Assessment of deterioration in epoxy/mica machine insulation , 1992 .

[7]  M. B. Srinivas,et al.  Pulse-count distribution as a possible diagnostic tool for assessing the level of degradation of rotating machine insulation , 1990 .

[8]  C. D. Smith,et al.  Application of ultrasound to the NDT of solid insulation , 1994 .

[9]  Hengkun Xie,et al.  Ultrasonic nondestructive detection for defects in epoxy/mica insulation , 2001, Proceedings of 2001 International Symposium on Electrical Insulating Materials (ISEIM 2001). 2001 Asian Conference on Electrical Insulating Diagnosis (ACEID 2001). 33rd Symposium on Electrical and Ele.

[10]  H. G. Sedding,et al.  The ability of diagnostic tests to estimate the remaining life of stator insulation , 1988 .

[11]  Ian Culbert,et al.  Assessment of insulation condition in rotating machine stators , 1992 .

[12]  S. Azizi-Ghannad,et al.  An acoustic diagnostic technique for use with electric machine insulation , 1994 .

[13]  Song Jiancheng,et al.  Study on UWB frequency characteristics of partial discharge as a criterion of aging degree of stator winding insulation , 2000, Proceedings of the 6th International Conference on Properties and Applications of Dielectric Materials (Cat. No.00CH36347).

[14]  T. Tsukui,et al.  Correlations between Nondestructive and Destructive Tests on High-Voltage Coil Insulations for Rotating Miachines , 1981, IEEE Transactions on Electrical Insulation.

[15]  K. Kimura Progress of insulation ageing and diagnostics of high voltage rotating machine windings in Japan , 1993, IEEE Electrical Insulation Magazine.