Compressed sensing in diffuse optical tomography.

Diffuse optical tomography (DOT) allows tomographic (3D), non-invasive reconstructions of tissue optical properties for biomedical applications. Severe under-sampling is a common problem in DOT which leads to image artifacts. A large number of measurements is needed in order to minimize these artifacts. In this work, we introduce a compressed sensing (CS) framework for DOT which enables improved reconstructions with under-sampled data. The CS framework uses a sparsifying basis, ℓ1-regularization and random sampling to reduce the number of measurements that are needed to achieve a certain accuracy. We demonstrate the utility of the CS framework using numerical simulations. The CS results show improved DOT results in comparison to "traditional" linear reconstruction methods based on singular-value decomposition (SVD) with ℓ2-regularization and with regular and random sampling. Furthermore, CS is shown to be more robust against the reduction of measurements in comparison to the other methods. Potential benefits and shortcomings of the CS approach in the context of DOT are discussed.

[1]  Harry Nyquist Certain Topics in Telegraph Transmission Theory , 1928 .

[2]  Ronald A. DeVore,et al.  Deterministic constructions of compressed sensing matrices , 2007, J. Complex..

[3]  J P Culver,et al.  Optimization of optode arrangements for diffuse optical tomography: A singular-value analysis. , 2001, Optics letters.

[4]  A. Yodh,et al.  Diffuse optics for tissue monitoring and tomography , 2010, Reports on progress in physics. Physical Society.

[5]  Dong Liang,et al.  Compressed-sensing Photoacoustic Imaging based on random optical illumination , 2009, Int. J. Funct. Informatics Pers. Medicine.

[6]  M. A. O'Leary,et al.  Imaging with diffuse photon density waves , 1996 .

[7]  S R Arridge,et al.  Recent advances in diffuse optical imaging , 2005, Physics in medicine and biology.

[8]  B. Pogue,et al.  Automated region detection based on the contrast-to-noise ratio in near-infrared tomography. , 2004, Applied optics.

[9]  Hongkai Zhao,et al.  Multilevel bioluminescence tomography based on radiative transfer equation Part 1: l1 regularization. , 2010, Optics express.

[10]  Joel A. Tropp,et al.  Signal Recovery From Random Measurements Via Orthogonal Matching Pursuit , 2007, IEEE Transactions on Information Theory.

[11]  B. Pogue,et al.  Spatially variant regularization improves diffuse optical tomography. , 1999, Applied optics.

[12]  Turgut Durduran,et al.  Sparse Image Reconstruction in Diffuse Optical Tomography: An Application of Compressed Sensing , 2010 .

[13]  E. Candès,et al.  Stable signal recovery from incomplete and inaccurate measurements , 2005, math/0503066.

[14]  M. Glas,et al.  Principles of Computerized Tomographic Imaging , 2000 .

[15]  Per Christian Hansen,et al.  Analysis of Discrete Ill-Posed Problems by Means of the L-Curve , 1992, SIAM Rev..

[16]  D. A. BOAStt,et al.  Scattering of diffuse photon density waves by spherical inhomogeneities within turbid media: Analytic solution and applications , 2022 .

[17]  M. Lustig,et al.  Compressed Sensing MRI , 2008, IEEE Signal Processing Magazine.

[18]  Peter Boesiger,et al.  Compressed sensing in dynamic MRI , 2008, Magnetic resonance in medicine.

[19]  Levent Onural,et al.  Graphics processing unit accelerated computation of digital holograms. , 2009, Applied optics.

[20]  Joel A. Tropp,et al.  Greed is good: algorithmic results for sparse approximation , 2004, IEEE Transactions on Information Theory.

[21]  Deanna Needell,et al.  Uniform Uncertainty Principle and Signal Recovery via Regularized Orthogonal Matching Pursuit , 2007, Found. Comput. Math..

[22]  Gene H. Golub,et al.  Singular value decomposition and least squares solutions , 1970, Milestones in Matrix Computation.

[23]  H. Nyquist,et al.  Certain Topics in Telegraph Transmission Theory , 1928, Transactions of the American Institute of Electrical Engineers.

[24]  Jie Tang,et al.  Prior image constrained compressed sensing (PICCS): a method to accurately reconstruct dynamic CT images from highly undersampled projection data sets. , 2008, Medical physics.

[25]  Stephen P. Boyd,et al.  An Interior-Point Method for Large-Scale $\ell_1$-Regularized Least Squares , 2007, IEEE Journal of Selected Topics in Signal Processing.

[26]  C.E. Shannon,et al.  Communication in the Presence of Noise , 1949, Proceedings of the IRE.

[27]  S Arridge,et al.  A gradient-based optimisation scheme foroptical tomography. , 1998, Optics express.

[28]  Daniel L Marks,et al.  Compressive holography. , 2009, Optics express.

[29]  Guillermo Sapiro,et al.  Learning to Sense Sparse Signals: Simultaneous Sensing Matrix and Sparsifying Dictionary Optimization , 2009, IEEE Transactions on Image Processing.

[30]  Michael P. Friedlander,et al.  Probing the Pareto Frontier for Basis Pursuit Solutions , 2008, SIAM J. Sci. Comput..

[31]  S. Arridge Optical tomography in medical imaging , 1999 .

[32]  S. Arridge,et al.  Optical tomography: forward and inverse problems , 2009, 0907.2586.

[33]  D. Donoho For most large underdetermined systems of linear equations the minimal 𝓁1‐norm solution is also the sparsest solution , 2006 .

[34]  V. Ntziachristos,et al.  Three-dimensional diffuse optical tomography in the parallel plane transmission geometry: evaluation of a hybrid frequency domain/continuous wave clinical system for breast imaging. , 2003, Medical physics.

[35]  William Thomlinson,et al.  Quantitative measurement of regional lung gas volume by synchrotron radiation computed tomography , 2005, Physics in medicine and biology.

[36]  R.G. Baraniuk,et al.  Compressive Sensing [Lecture Notes] , 2007, IEEE Signal Processing Magazine.

[37]  Lihong V Wang,et al.  Compressed sensing in photoacoustic tomography in vivo. , 2010, Journal of biomedical optics.

[38]  R. J. Gaudette,et al.  A comparison study of linear reconstruction techniques for diffuse optical tomographic imaging of absorption coefficient. , 2000, Physics in medicine and biology.

[39]  Stephen P. Boyd,et al.  Enhancing Sparsity by Reweighted ℓ1 Minimization , 2007, 0711.1612.

[40]  Edmund Y Lam,et al.  Image reconstruction using spectroscopic and hyperspectral information for compressive terahertz imaging. , 2010, Journal of the Optical Society of America. A, Optics, image science, and vision.

[41]  Arye Nehorai,et al.  Image reconstruction for diffuse optical tomography using sparsity regularization and expectation-maximization algorithm. , 2007, Optics express.

[42]  Hamid Dehghani,et al.  Depth sensitivity and image reconstruction analysis of dense imaging arrays for mapping brain function with diffuse optical tomography. , 2009, Applied optics.

[43]  A. Darzi,et al.  Diffuse optical imaging of the healthy and diseased breast: A systematic review , 2008, Breast Cancer Research and Treatment.

[44]  E. Candès,et al.  Sparsity and incoherence in compressive sampling , 2006, math/0611957.

[45]  李幼升,et al.  Ph , 1989 .

[46]  D. Donoho,et al.  Sparse MRI: The application of compressed sensing for rapid MR imaging , 2007, Magnetic resonance in medicine.

[47]  Jong Chul Ye,et al.  Exact reconstruction formula for diffuse optical tomography using simultaneous sparse representation , 2008, 2008 5th IEEE International Symposium on Biomedical Imaging: From Nano to Macro.

[48]  A. Adibi,et al.  Optimal sparse solution for fluorescent diffuse optical tomography: theory and phantom experimental results. , 2007, Applied optics.

[49]  Hengyong Yu,et al.  Compressed sensing based interior tomography , 2009, Physics in medicine and biology.

[50]  Deanna Needell,et al.  CoSaMP: Iterative signal recovery from incomplete and inaccurate samples , 2008, ArXiv.

[51]  I Céspedes,et al.  Fundamental mechanical limitations on the visualization of elasticity contrast in elastography. , 1995, Ultrasound in medicine & biology.

[52]  Frédéric Lesage,et al.  The Application of Compressed Sensing for Photo-Acoustic Tomography , 2009, IEEE Transactions on Medical Imaging.