Thermodynamic analysis of a novel energy-efficient refrigeration system subcooled by liquid desiccant dehumidification and evaporation

A new energy-efficient refrigeration system subcooled by liquid desiccant dehumidification and evaporation was proposed in this paper. In the system, liquid desiccant system could produce very dry air for an indirect evaporative cooler, which would subcool the vapor compression refrigeration system to get higher COP than conventional refrigeration system. The desiccant cooling system can use the condensation heat for the desiccant regeneration. Thermodynamic analysis is made to discuss the effects of operation parameters (condensing temperature, liquid desiccant concentration, ambient air temperature and relative humidity) on the system performance. Results show that the proposed hybrid vapor compression refrigeration system achieves significantly higher COP than conventional vapor compression refrigeration system, and even higher than the reverse Carnot cycle at the same operation conditions. The maximum COPs of the hybrid systems using hot air and ambient air are 18.8% and 16.3% higher than that of the conventional vapor compression refrigeration system under varied conditions, respectively.

[1]  Gaoming Ge,et al.  Performance analysis of liquid desiccant based air-conditioning system under variable fresh air rati , 2010 .

[2]  I. C. Finlay,et al.  Evaporative cooling of tube banks , 1984 .

[3]  W. L. Lee,et al.  The use of helical heat exchanger for heat recovery domestic water-cooled air-conditioners , 2009 .

[4]  Xiaosong Zhang,et al.  A new method for determining coupled heat and mass transfer coefficients between air and liquid desiccant , 2008 .

[5]  Dominique Marchio,et al.  Simplified model for indirect-contact evaporative cooling-tower behaviour , 2004 .

[6]  Ruzhu Wang,et al.  Use of liquid desiccant cooling to improve the performance of vapor compression air conditioning , 2001 .

[7]  Ruzhu Wang,et al.  Research on refrigerant flow characteristics and performance of a multi-functional heat pump system , 2011 .

[8]  J. Guilpart,et al.  Numerical model of sprayed air cooled condenser coupled to refrigerating system , 2007 .

[9]  Sih-Li Chen,et al.  Performance enhancement of a subcooled cold storage air conditioning system , 2009 .

[10]  J. Duffie,et al.  Cooling with solar energy , 1961 .

[11]  Manuel R. Conde,et al.  Properties of aqueous solutions of lithium and calcium chlorides: formulations for use in air conditioning equipment design , 2004 .

[12]  Syed M. Zubair,et al.  The effect of refrigerant combinations on performance of a vapor compression refrigeration system with dedicated mechanical sub-cooling , 2012 .

[13]  Xiaosong Zhang,et al.  Experimental study on dehumidifier and regenerator of liquid desiccant cooling air conditioning system , 2007 .

[14]  Orhan Büyükalaca,et al.  Experimental investigation of a novel configuration of desiccant based evaporative air conditioning system , 2013 .

[15]  James E. Braun,et al.  An effectiveness model of liquid-desiccant system heat/mass exchangers , 1989 .

[16]  S. C. Kaushik,et al.  Feasibility and design studies for heat recovery from a refrigeration system with a canopus heat exchanger , 1995 .

[17]  Bo-Ren Chen,et al.  Application of thermal battery in the ice storage air-conditioning system as a subcooler , 2007 .

[18]  Thermal performance of cold storage in thermal battery for air conditioning , 2004 .

[19]  Alfonso William Mauro,et al.  A chart for predicting the possible advantage of adopting a suction/liquid heat exchanger in refrigerating system , 2007 .

[20]  Zhongliang Liu,et al.  An experimental study on the heat transfer characteristics of a heat pipe heat exchanger with latent heat storage. Part II: Simultaneous charging/discharging modes , 2006 .

[21]  Chih Wu,et al.  A new heat recovery technique for air-conditioning/heat-pump system , 2008 .

[22]  Per Lundqvist,et al.  Heat recovery and floating condensing in supermarkets , 2006 .

[23]  Rodrigo Llopis,et al.  Energetic evaluation of an internal heat exchanger in a CO2 transcritical refrigeration plant using experimental data , 2011 .

[24]  Zhongliang Liu,et al.  An experimental study on heat transfer characteristics of heat pipe heat exchanger with latent heat storage. Part I: Charging only and discharging only modes , 2006 .

[25]  Luis Pérez-Lombard,et al.  A review on buildings energy consumption information , 2008 .

[26]  G. Fang,et al.  Dynamic charging characteristics modeling of heat storage device with heat pipe , 2011 .

[27]  Haruki Sato,et al.  Proposal of an eco-friendly high-performance air-conditioning system part 2. Application of evapo-transpiration condenser to residential air-conditioning system , 2013 .

[28]  W. Kessling,et al.  ENERGY STORAGE FOR DESICCANT COOLING SYSTEMS COMPONENT DEVELOPMENT , 1998 .

[29]  Yu-Fu Kuo,et al.  Performance enhancement of a heat pump system with ice storage subcooler , 2010 .

[30]  Eric Kozubal,et al.  A desiccant-enhanced evaporative air conditioner: Numerical model and experiments , 2013 .

[31]  Mohamed A. Antar,et al.  Experimental energetic analysis of a vapor compression refrigeration system with dedicated mechanical sub-cooling , 2013 .

[32]  Syed M. Zubair,et al.  Design and rating of an integrated mechanical-subcooling vapor-compression refrigeration system , 2000 .

[33]  E. Hajidavalloo,et al.  Performance improvement of air-cooled refrigeration system by using evaporatively cooled air condenser. , 2010 .

[34]  E. D. Rogdakis,et al.  Thermodynamic study of the effects of ambient air conditions on the thermal performance characteristics of a closed wet cooling tower , 2012 .

[35]  Mei Yu,et al.  Experimental research on condensing heat recovery using phase change material , 2011 .

[36]  B. A. Qureshi,et al.  Cost optimization of heat exchanger inventory for mechanical subcooling refrigeration cycles , 2013 .

[37]  C. Hermes Alternative evaluation of liquid-to-suction heat exchange in the refrigeration cycle , 2013 .

[38]  Guangcai Gong,et al.  Thermodynamic simulation of condensation heat recovery characteristics of a single stage centrifugal chiller in a hotel , 2012 .