Predictive modeling of lung motion over the entire respiratory cycle using measured pressure-volume data, 4DCT images, and finite-element analysis.

PURPOSE Predicting complex patterns of respiration can benefit the management of the respiratory motion for radiation therapy of lung cancer. The purpose of the present work was to develop a patient-specific, physiologically relevant respiratory motion model which is capable of predicting lung tumor motion over a complete normal breathing cycle. METHODS Currently employed techniques for generating the lung geometry from four-dimensional computed tomography data tend to lose details of mesh topology due to excessive surface smoothening. Some of the existing models apply displacement boundary conditions instead of the intrapleural pressure as the actual motive force for respiration, while others ignore the nonlinearity of lung tissues or the mechanics of pleural sliding. An intermediate nonuniform rational basis spline surface representation is used to avoid multiple geometric smoothing procedures used in the computational mesh preparation. Measured chest pressure-volume relationships are used to simulate pressure loading on the surface of the model for a given lung volume, as in actual breathing. A hyperelastic model, developed from experimental observations, has been used to model the lung tissue material. Pleural sliding on the inside of the ribcage has also been considered. RESULTS The finite-element model has been validated using landmarks from four patient CT data sets over 34 breathing phases. The average differences of end-inspiration in position between the landmarks and those predicted by the model are observed to be 0.450 +/- 0.330 cm for Patient P1, 0.387 +/- 0.169 cm for Patient P2, 0.319 +/- 0.186 cm for Patient P3, and 0.204 +/- 0.102 cm for Patient P4 in the magnitude of error vector, respectively. The average errors of prediction at landmarks over multiple breathing phases in superior-inferior direction are less than 3 mm. CONCLUSIONS The prediction capability of pressure-volume curve driven nonlinear finite-element model is consistent over the entire breathing cycle. The biomechanical parameters in the model are physiologically measurable, so that the results can be extended to other patients and additional neighboring organs affected by respiratory motion.

[1]  Gregory C Sharp,et al.  Prediction of respiratory tumour motion for real-time image-guided radiotherapy. , 2004, Physics in medicine and biology.

[2]  M. V. van Herk,et al.  Respiratory correlated cone beam CT. , 2005, Medical physics.

[3]  E SALAZAR,et al.  AN ANALYSIS OF PRESSURE-VOLUME CHARACTERISTICS OF THE LUNGS. , 1964, Journal of applied physiology.

[4]  Heinz Handels,et al.  Modeling respiratory lung motion: a biophysical approach using finite element methods , 2008, SPIE Medical Imaging.

[5]  Marcel van Herk,et al.  Portal imaging to assess set-up errors, tumor motion and tumor shrinkage during conformal radiotherapy of non-small cell lung cancer. , 2001, Radiotherapy and oncology : journal of the European Society for Therapeutic Radiology and Oncology.

[6]  S. Lai-Fook,et al.  Pleural mechanics and fluid exchange. , 2004, Physiological reviews.

[7]  K. Brock,et al.  Accuracy of finite element model-based multi-organ deformable image registration. , 2005, Medical physics.

[8]  R. Mohan,et al.  Acquiring a four-dimensional computed tomography dataset using an external respiratory signal. , 2003, Physics in medicine and biology.

[9]  Radhe Mohan,et al.  Four-dimensional radiotherapy planning for DMLC-based respiratory motion tracking. , 2005, Medical physics.

[10]  Jannick P. Rolland,et al.  Modeling Real-Time 3-D Lung Deformations for Medical Visualization , 2008, IEEE Transactions on Information Technology in Biomedicine.

[11]  F L Matthews,et al.  Stresses, strains, and surface pressures in the lung caused by its weight. , 1972, Journal of applied physiology.

[12]  Yaxi Liu,et al.  Development of a Novel Post-processing Treatment Planning Platform for 4D Radiotherapy , 2008, Technology in cancer research & treatment.

[13]  Andrew Gouldstone,et al.  Lubrication regimes in mesothelial sliding. , 2005, Journal of biomechanics.

[14]  K. Brock,et al.  Adapting liver motion models using a navigator channel technique. , 2009, Medical physics.

[15]  B. Shariat,et al.  Breathing Thorax Simulation based on Pleura Physiology and Rib Kinematics , 2007, International Conference on Medical Information Visualisation - BioMedical Visualisation (MediVis 2007).

[16]  Wei Lu,et al.  4D-CT motion estimation using deformable image registration and 5D respiratory motion modeling. , 2008, Medical physics.

[17]  Lena Specht,et al.  The role of image guidance in respiratory gated radiotherapy , 2008, Acta oncologica.

[18]  Martin J Murphy,et al.  Optimization of an adaptive neural network to predict breathing. , 2008, Medical physics.

[19]  C. Ling,et al.  Respiration-correlated spiral CT: a method of measuring respiratory-induced anatomic motion for radiation treatment planning. , 2002, Medical physics.

[20]  X Allen Li,et al.  Point/counterpoint. Respiratory gating for radiation therapy is not ready for prime time. , 2007, Medical physics.

[21]  Steve B. Jiang,et al.  The management of respiratory motion in radiation oncology report of AAPM Task Group 76. , 2006, Medical physics.

[22]  Pierre-Frédéric Villard,et al.  Lung mesh generation to simulate breathing motion with a finite element method , 2004 .

[23]  Martin J Murphy,et al.  Fiducial-based targeting accuracy for external-beam radiotherapy. , 2002, Medical physics.

[24]  G. Christensen,et al.  A method for the reconstruction of four-dimensional synchronized CT scans acquired during free breathing. , 2003, Medical physics.

[25]  T. Landberg,et al.  What margins should be added to the clinical target volume in radiotherapy treatment planning for lung cancer? , 1998, Radiotherapy and oncology : journal of the European Society for Therapeutic Radiology and Oncology.

[26]  Steve B. Jiang,et al.  Effects of motion on the total dose distribution. , 2004, Seminars in radiation oncology.

[27]  E Yorke,et al.  Four-dimensional (4D) PET/CT imaging of the thorax. , 2004, Medical physics.

[28]  S. Webb,et al.  Planning lung radiotherapy using 4D CT data and a motion model , 2008, Physics in medicine and biology.

[29]  A. McCulloch,et al.  Finite element stress analysis of left ventricular mechanics in the beating dog heart. , 1995, Journal of biomechanics.

[30]  B. Shariat,et al.  Simulation of lung behaviour with finite elements: influence of bio-mechanical parameters , 2005, Third International Conference on Medical Information Visualisation--BioMedical Visualisation.

[31]  Hans-Ulrich Kauczor,et al.  Analysis of intrathoracic tumor mobility during whole breathing cycle by dynamic MRI. , 2004, International journal of radiation oncology, biology, physics.

[32]  Adil Al-Mayah,et al.  Effect of Friction and Material Compressibility on Deformable Modeling of Human Lung , 2008, ISBMS.

[33]  Hiroki Shirato,et al.  Adaptive prediction of respiratory motion for motion compensation radiotherapy , 2007, Physics in medicine and biology.

[34]  V. Boldea,et al.  Simulation of four-dimensional CT images from deformable registration between inhale and exhale breath-hold CT scans. , 2006, Medical physics.

[35]  G. Holzapfel SECTION 10.11 – Biomechanics of Soft Tissue , 2001 .

[36]  Bhudatt R Paliwal,et al.  Technical note: A novel boundary condition using contact elements for finite element based deformable image registration. , 2004, Medical physics.

[37]  M. V. van Herk,et al.  Precise and real-time measurement of 3D tumor motion in lung due to breathing and heartbeat, measured during radiotherapy. , 2002, International journal of radiation oncology, biology, physics.

[38]  Sonja Dieterich,et al.  Comparative performance of linear and nonlinear neural networks to predict irregular breathing , 2006, Physics in medicine and biology.

[39]  Y C Fung,et al.  Measurement of the mechanical properties of the human lung tissue. , 1987, Journal of biomechanical engineering.

[40]  K. Camphausen,et al.  Advances in 4D Medical Imaging and 4D Radiation Therapy , 2008, Technology in cancer research & treatment.

[41]  S. Webb Motion effects in (intensity modulated) radiation therapy: a review , 2006, Physics in medicine and biology.

[42]  D. Stamenović,et al.  Biomechanics of the lung parenchyma: critical roles of collagen and mechanical forces. , 2005, Journal of applied physiology.

[43]  J Moseley,et al.  Contact surface and material nonlinearity modeling of human lungs , 2008, Physics in medicine and biology.

[44]  L. Xing,et al.  Overview of image-guided radiation therapy. , 2006, Medical dosimetry : official journal of the American Association of Medical Dosimetrists.

[45]  Heinz Handels,et al.  Patient-specific finite element modeling of respiratory lung motion using 4D CT image data. , 2009, Medical physics.

[46]  Patrick Clarysse,et al.  A Comparison Framework for Breathing Motion Estimation Methods From 4-D Imaging , 2007, IEEE Transactions on Medical Imaging.

[47]  D Ruan,et al.  Real-time prediction of respiratory motion based on local regression methods , 2007, Physics in medicine and biology.

[48]  S. Loring,et al.  Friction and lubrication of pleural tissues , 2004, Respiratory Physiology & Neurobiology.

[49]  F L Matthews,et al.  Finite element displacement analysis of a lung. , 1972, Journal of biomechanics.

[50]  M. V. van Herk,et al.  Physical aspects of a real-time tumor-tracking system for gated radiotherapy. , 2000, International journal of radiation oncology, biology, physics.