Multilayered construction of glucose oxidase and poly(allylamine)ferrocene on gold electrodes by means of layer-by-layer covalent attachment

[1]  I. Willner,et al.  Self-powered enzyme-based biosensors. , 2001, Journal of the American Chemical Society.

[2]  C. Danilowicz,et al.  Layer-by-layer self-assembly of glucose oxidase and Os(Bpy)2CIPyCH2NH-poly(allylamine) bioelectrode. , 2001, Analytical chemistry.

[3]  H. S. Kim,et al.  Functionalization of a poly(amidoamine) dendrimer with ferrocenyls and its application to the construction of a reagentless enzyme electrode. , 2000, Analytical chemistry.

[4]  Katz,et al.  Integration of Layered Redox Proteins and Conductive Supports for Bioelectronic Applications. , 2000, Angewandte Chemie.

[5]  Kim,et al.  Multilayered assembly of dendrimers with enzymes on gold: thickness-controlled biosensing interface , 2000, Analytical chemistry.

[6]  Jia-cong Shen,et al.  Chemically modified electrode via layer-by-layer deposition of glucose oxidase (GOD) and polycation-bearing Os complex , 1998 .

[7]  Jose H. Hodak,et al.  Layer-by-Layer Self-Assembly of Glucose Oxidase with a Poly(allylamine)ferrocene Redox Mediator , 1997 .

[8]  Itamar Willner,et al.  Bioelectrocatalyzed Amperometric Transduction of Recorded Optical Signals Using Monolayer-Modified Au-Electrodes1 , 1995 .

[9]  Katsuhiko Ariga,et al.  ASSEMBLY OF MULTICOMPONENT PROTEIN FILMS BY MEANS OF ELECTROSTATIC LAYER-BY-LAYER ADSORPTION , 1995 .

[10]  Itamar Willner,et al.  Development of novel biosensor enzyme electrodes: Glucose oxidase multilayer arrays immobilized onto self‐assembled monolayers on electrodes , 1993 .

[11]  Jean-Michel Savéant,et al.  A fully active monolayer enzyme electrode derivatized by antigen-antibody attachment , 1993 .

[12]  A. Ryabov,et al.  Chemical Attachment of Organometallics to Proteins in Reverse Micelles , 1992 .

[13]  Adam Heller,et al.  Electron Transfer between Glucose Oxidase and Electrodes via Redox Mediators Bound with Flexible Chains to the Enzyme Surface , 1991 .

[14]  Adam Heller,et al.  Electrical Wiring of Redox Enzymes , 1990 .

[15]  Adam Heller,et al.  Direct electrical communication between chemically modified enzymes and metal electrodes. I. Electron transfer from glucose oxidase to metal electrodes via electron relays, bound covalently to the enzyme , 1987 .

[16]  K. Koga,et al.  Effect of periodate oxidation on the structure and properties of glucose oxidase. , 1976, Biochimica et biophysica acta.

[17]  O. Zaborsky,et al.  The immobilization of glucose oxidase via activation of its carbohydrate residues. , 1974, Biochemical and biophysical research communications.

[18]  G. S. Wilson,et al.  Biosensors : fundamentals and applications , 1987 .