Enhanced Control and Operation of DFIG-Based Wind Farms During Network Unbalance

This paper investigates the control and operation of doubly fed induction generator (DFIG)-based wind generation systems under unbalanced voltage conditions. DFIG system behaviors under unbalanced voltage are analyzed and different control targets are discussed. A new rotor current control strategy containing a main controller and an auxiliary controller is proposed. The main controller is implemented in the positive (dq)+ frame without involving positive/negative sequence decomposition, whereas the auxiliary controller is implemented in the negative (dq)- frame with negative sequence current extracted. The impact of providing unbalanced control on converter voltage rating is investigated. Simulation results using EMTDC/PSCAD are presented for a 2-MW DFIG wind generation system to validate the proposed control scheme and to demonstrate the enhanced system operation during ldquosmallrdquo steady state and ldquolargerdquo transient unbalances.

[1]  N. Mohan,et al.  A novel H/sub /spl infin// based controller for wind turbine applications operating under unbalanced voltage conditions , 2005, Proceedings of the 13th International Conference on, Intelligent Systems Application to Power Systems.

[2]  M. Yamamoto,et al.  Active and reactive power control of doubly-fed wound rotor induction generator , 1990, 21st Annual IEEE Conference on Power Electronics Specialists.

[3]  R. W. De Doncker,et al.  Doubly fed induction generator systems for wind turbines , 2002 .

[4]  N. Mohan,et al.  Control of a Doubly Fed Induction Wind Generator Under Unbalanced Grid Voltage Conditions , 2007, IEEE Transactions on Energy Conversion.

[5]  Ned Mohan,et al.  A novel doubly-fed induction wind generator control scheme for reactive power control and torque pulsation compensation under unbalanced grid voltage conditions , 2003, IEEE 34th Annual Conference on Power Electronics Specialist, 2003. PESC '03..

[6]  Lie Xu,et al.  Dynamic Modeling and Control of DFIG-Based Wind Turbines Under Unbalanced Network Conditions , 2007, IEEE Transactions on Power Systems.

[7]  Hirofumi Akagi,et al.  Control and performance of a doubly-fed induction machine intended for a flywheel energy storage system , 2002 .

[8]  H. van der Broeck,et al.  Analysis and Realization of a Pulse Width Modulator Based on Voltage Space Vectors , 1986, 1986 Annual Meeting Industry Applications Society.

[9]  Robert H. Lasseter,et al.  Statcom controls for operation with unbalanced voltages , 1998 .