What makes an accurate and reliable subject-specific finite element model? A case study of an elephant femur

Finite element modelling is well entrenched in comparative vertebrate biomechanics as a tool to assess the mechanical design of skeletal structures and to better comprehend the complex interaction of their form–function relationships. But what makes a reliable subject-specific finite element model? To approach this question, we here present a set of convergence and sensitivity analyses and a validation study as an example, for finite element analysis (FEA) in general, of ways to ensure a reliable model. We detail how choices of element size, type and material properties in FEA influence the results of simulations. We also present an empirical model for estimating heterogeneous material properties throughout an elephant femur (but of broad applicability to FEA). We then use an ex vivo experimental validation test of a cadaveric femur to check our FEA results and find that the heterogeneous model matches the experimental results extremely well, and far better than the homogeneous model. We emphasize how considering heterogeneous material properties in FEA may be critical, so this should become standard practice in comparative FEA studies along with convergence analyses, consideration of element size, type and experimental validation. These steps may be required to obtain accurate models and derive reliable conclusions from them.

[1]  Arturo Cifuentes,et al.  A performance study of tetrahedral and hexahedral elements in 3-D finite element structural analysis , 1992 .

[2]  David S Strait,et al.  Modeling elastic properties in finite-element analysis: how much precision is needed to produce an accurate model? , 2005, The anatomical record. Part A, Discoveries in molecular, cellular, and evolutionary biology.

[3]  Sheng Liu,et al.  Measurement of Strain Distributions in Mouse Femora with 3D-Digital Speckle Pattern Interferometry. , 2007, Optics and lasers in engineering.

[4]  O Panagiotopoulou,et al.  Modelling subcortical bone in finite element analyses: A validation and sensitivity study in the macaque mandible. , 2010, Journal of biomechanics.

[5]  David S Strait,et al.  Finite element analysis in functional morphology. , 2005, The anatomical record. Part A, Discoveries in molecular, cellular, and evolutionary biology.

[6]  J. Hutchinson,et al.  Some basic relationships between density values in cancellous and cortical bone. , 2008, Journal of biomechanics.

[7]  M L Bouxsein,et al.  Effect of local density changes on the failure load of the proximal femur , 1999, Journal of orthopaedic research : official publication of the Orthopaedic Research Society.

[8]  R. McN. Alexander,et al.  Allometry of the limb bones of mammals from shrews (Sorex) to elephant (Loxodonta) , 2009 .

[9]  M. Viceconti,et al.  A modified method for assigning material properties to FE models of bones. , 2008, Medical engineering & physics.

[10]  C. L. Chang,et al.  Finite element simulation of wheel impact test , 2008 .

[11]  Jamshid Tehranzadeh,et al.  Predicting Proximal Femoral Strength Using Structural Engineering Models , 2005, Clinical orthopaedics and related research.

[12]  Michael Bottlang,et al.  Malrotation in total knee arthroplasty: effect on tibial cortex strain captured by laser-based strain acquisition. , 2006, Clinical biomechanics.

[13]  John R Hutchinson,et al.  On the inference of function from structure using biomechanical modelling and simulation of extinct organisms , 2012, Biology Letters.

[14]  John R. Tyrer,et al.  Three-dimensional human femoral strain analysis using ESPI , 1995 .

[15]  E. Rayfield Finite Element Analysis and Understanding the Biomechanics and Evolution of Living and Fossil Organisms , 2007 .

[16]  Yoon-Ho Cho,et al.  Considerations on Finite-Element Method Application in Pavement Structural Analysis , 1996 .

[17]  Patrick J McMahon,et al.  Methodology and sensitivity studies for finite element modeling of the inferior glenohumeral ligament complex. , 2007, Journal of biomechanics.

[18]  Chia-Lung Chang,et al.  Simulation of wheel impact test using finite element method , 2009 .

[19]  V. B. Kokshenev,et al.  Salient features in the locomotion of proboscideans revealed via the differential scaling of limb long bones , 2010 .

[20]  P Zioupos,et al.  The effects of ageing and changes in mineral content in degrading the toughness of human femora. , 1997, Journal of biomechanics.

[21]  J. Currey,et al.  Changes in the impact energy absorption of bone with age. , 1979, Journal of biomechanics.

[22]  Kozo Nakamura,et al.  Prediction of strength and strain of the proximal femur by a CT-based finite element method. , 2007, Journal of biomechanics.

[23]  O Panagiotopoulou,et al.  Finite element analysis (FEA): Applying an engineering method to functional morphology in anthropology and human biology , 2009, Annals of human biology.

[24]  Kornelius Kupczik,et al.  The mechanical function of the periodontal ligament in the macaque mandible: a validation and sensitivity study using finite element analysis , 2011, Journal of anatomy.

[25]  Steven E. Benzley,et al.  A Comparison of All Hexagonal and All Tetrahedral Finite Element Meshes for Elastic and Elasto-plastic Analysis , 2011 .

[26]  Sandra J Shefelbine,et al.  BoneJ: Free and extensible bone image analysis in ImageJ. , 2010, Bone.

[27]  Jamshid Tehranzadeh,et al.  Predicting the Strength of Femoral Shafts with and without Metastatic Lesions , 2005, Clinical orthopaedics and related research.