Influence of rotational speed, torque and operator proficiency on failure of Greater Taper files.

AIM The purpose of this study was to evaluate the influence of rotational speed. torque, and operator experience on the incidence of locking, deformation, and separation of instruments when using a specific Ni-Ti rotary instrumentation technique in extracted human teeth. METHODOLOGY Greater Taper Ni-Ti rotary instruments (GT) were used in a crown-down technique. In one group (rotational speed evaluation) of canals (n = 300) speeds of 150, 2 50 and 350 r.p.m. (subgroups 1, 2 and 3) were used. Each one of the subgroups included 100 canals. In a second group (evaluation of torque) (n = 300) torque was set at 20, 30 and 55 Ncm (subgroups 4, 5 and 6). In the third group (evaluation of operator proficiency) (n = 300 three operators with varying experience (subgroups 7, 8 and 9) were also compared. Each subgroup included the use of 10 sets of GT rotary instruments and 100 canals of extracted human molars. Each set of instruments was used in up to 10 canals and sterilized before each case. NaOCl 2.5% was used as an irrigant. The number of locked, deformed, and separated instruments was recorded for each group. Statistical analysis was carried out with pairwise comparisons using Fisher's exact tests for each of the failure type. RESULTS When the influence of rotational speed was evaluated, instrument deformation and separation did not occur in subgroups 1 (150) r.p.m.), 2 (250 r.p.m.), and 3 (350) r.p.m.). Instrument locking occurred in subgroup 3 only. Statistical analysis demonstrated a significant difference between the 150 and 350 r.p.m. groups and between the 250 and 350 r.p.m. groups with respect to instrument locking. In torque evaluation, neither separation, deformation nor locking occurred during the use of the instruments, at 150 r.p.m., and at the different torque values. When the operators were compared, although two instruments were separated in canals prepared by the least experienced operator. Fisher's exact tests did not demonstrate a significant difference between the three subgroups. Instrument locking, deformation, and separation did not occur with the most experienced operator. None of the instruments separated with the trained operator. CONCLUSIONS Preclinical training in the use of the GT rotary instruments when used with a crown-down technique at 150 r.p.m. was crucial in avoiding instrument separation and reducing the incidence of instrument locking and deformation.

[1]  S. W. Schneider,et al.  A comparison of canal preparations in straight and curved root canals. , 1971, Oral surgery, oral medicine, and oral pathology.

[2]  H Schilder,et al.  Cleaning and shaping the root canal. , 1974, Dental clinics of North America.

[3]  Marco Ramirez-Salomon,et al.  Incidence of Lightspeed separation and the potential for bypassing. , 1997, Journal of endodontics.

[4]  J. P. Pruett,et al.  Cyclic fatigue testing of nickel-titanium endodontic instruments. , 1997, Journal of endodontics.

[5]  C Kobayashi,et al.  A new engine-driven canal preparation system with electronic canal measuring capability. , 1997, Journal of endodontics.

[6]  F. Barbakow,et al.  The 'Lightspeed' preparation technique evaluated by Swiss clinicians after attending continuing education courses. , 1997, International endodontic journal.

[7]  S A Thompson,et al.  Shaping ability of Profile rotary nickel-titanium instruments with ISO sized tips in simulated root canals: Part 1. , 2002, International endodontic journal.

[8]  S. A. Thompson,et al.  Shaping ability of Quantec Series 2000 rotary nickel-titanium instruments in simulated root canals: Part 1. , 2002, International endodontic journal.

[9]  J. Powers,et al.  Effects of simulated clinical conditions on nickel-titanium rotary files. , 1999, Journal of endodontics.

[10]  Jean-Paul Micallef,et al.  Location of contact areas on rotary Profile1 instruments in relationship to the forces developed during mechanical preparation on extracted teeth , 1999 .

[11]  F E Pink,et al.  Effect of rotational speed on nickel-titanium file distortion. , 1999, Journal of endodontics.

[12]  E Mandel,et al.  Rotary Ni-Ti profile systems for preparing curved canals in resin blocks: influence of operator on instrument breakage. , 1999, International endodontic journal.

[13]  G. Yared,et al.  Cyclic fatigue of Profile rotary instruments after simulated clinical use. , 1999, International endodontic journal.

[14]  H H Messer,et al.  Torque during canal instrumentation using rotary nickel-titanium files. , 2000, Journal of endodontics.

[15]  P Machtou,et al.  Cyclic fatigue of ProFile rotary instruments after clinical use. , 2000, International endodontic journal.

[16]  G. Yared,et al.  Influence of rotational speed, torque and operator's proficiency on ProFile failures. , 2001, International endodontic journal.