Comparison of Three Kinematic Analyses of the Knee: Determination of Intrinsic Features and Applicability to Intraoperative Procedures

The evaluation of knee motion is an important step for correct diagnoses and optimal surgical reconstructions, but controversial opinions still remain about the most suitable numerical method for the elaboration of clinical kinematic tests. In this paper, we present a comparison of three methods applied to an experimental animal study (Grood and Suntay method [Grood, E.S. and Suntay, W.J. (1983) "A coordinate system for the clinical description of three-dimensional motions: application to the knee", J. Biomech. Engng , 105 , pp. 136-144], Helical Axes method [Blankevoort, L., Huiskes, R. and de Lange, A. (1990). "Helical axes of passive knee joint motions", J. Biomech. , 23 pp. 1219-1229] and Functional method [Martelli, S., Zaffagnini, S., Falcioni, B. and Marcacci, M. (2000). "Intraoperative kinematic protocol for knee joint evaluation", Comput. Methods Programs Biomed. , 62 pp. 77-86]). The study shows the numerical differences among the three protocols and evaluates their performances and repeatability during clinical tests, i.e. laxity measurements and passive range of motion. The Functional method gives the optimal compromise among accuracy, clinical interpretability and ease of use for intraoperative kinematic evaluations.

[1]  C. Spoor,et al.  Rigid body motion calculated from spatial co-ordinates of markers. , 1980, Journal of biomechanics.

[2]  Stefano Zaffagnini,et al.  Intraoperative kinematic protocol for knee joint evaluation , 2000, Comput. Methods Programs Biomed..

[3]  R Huiskes,et al.  Effects of data smoothing on the reconstruction of helical axis parameters in human joint kinematics. , 1990, Journal of biomechanical engineering.

[4]  F K Fuss,et al.  Anatomy and function of the cruciate ligaments of the domestic pig (Sus scrofa domestica): a comparison with human cruciates. , 1991, Journal of anatomy.

[5]  E S Grood,et al.  A joint coordinate system for the clinical description of three-dimensional motions: application to the knee. , 1983, Journal of biomechanical engineering.

[6]  F. Fuss Anatomy and function of the cruciate ligaments of the domestic pig (Sus scrofa domestica): a comparison with human cruciates. , 1991, Journal of anatomy.

[7]  R. Johnson,et al.  Clinical versus instrumented knee testing on autopsy specimens. , 1992, Clinical orthopaedics and related research.

[8]  R van Dijk,et al.  Roentgen stereophotogrammetric methods for the evaluation of the three dimensional kinematic behaviour and cruciate ligament length patterns of the human knee joint. , 1979, Journal of biomechanics.

[9]  P R Cavanagh,et al.  ISB recommendations for standardization in the reporting of kinematic data. , 1995, Journal of biomechanics.

[10]  G. Scuderi**,et al.  Knee surgery. , 1990, Current opinion in rheumatology.

[11]  John Pearce,et al.  The Clinical Examination , 2008 .

[12]  L. Snyder-Mackler,et al.  Instrumented examination of knee laxity in patients with anterior cruciate deficiency: a comparison of the KT-2000, Knee Signature System, and Genucom. , 1994, Journal of Orthopaedic and Sports Physical Therapy.

[13]  H. Woltring 3-D attitude representation of human joints: a standardization proposal. , 1994, Journal of biomechanics.

[14]  R Huiskes,et al.  Measurement errors in roentgen-stereophotogrammetric joint-motion analysis. , 1990, Journal of biomechanics.

[15]  L Blankevoort,et al.  Helical axes of passive knee joint motions. , 1990, Journal of biomechanics.

[16]  M S Hefzy,et al.  Error analysis of a system for measuring three-dimensional joint motion. , 1983, Journal of biomechanical engineering.

[17]  Ashutosh Kumar Singh,et al.  The Axes of Rotation of the Knee , 1993, Clinical orthopaedics and related research.

[18]  S Martelli,et al.  Rotational laxity after anterior cruciate ligament injury by kinematic evaluation of clinical tests. , 2000, Journal of medical engineering & technology.

[19]  T. Santner,et al.  Measurement reproducibility of two commercial knee test devices , 1991, Journal of orthopaedic research : official publication of the Orthopaedic Research Society.

[20]  F Freudenstein,et al.  Kinematics of the human knee joint. , 1969, The Bulletin of mathematical biophysics.

[21]  Y. Ishii,et al.  Three-dimensional kinematics of the human knee with intracortical pin fixation. , 1997, Clinical orthopaedics and related research.

[22]  J L Lewis,et al.  6R instrumented spatial linkages for anatomical joint motion measurement--Part 2: Calibration. , 1992, Journal of biomechanical engineering.

[23]  E. Chao,et al.  Justification of triaxial goniometer for the measurement of joint rotation. , 1980, Journal of biomechanics.

[24]  F. Veldpaus,et al.  Finite centroid and helical axis estimation from noisy landmark measurements in the study of human joint kinematics. , 1985, Journal of biomechanics.

[25]  P R Cavanagh,et al.  Foot inversion‐eversion and knee kinematics during walking , 1994, Journal of orthopaedic research : official publication of the Orthopaedic Research Society.

[26]  C D Mote,et al.  A six-degree-of-freedom acoustic transducer for rotation and translation measurements across the knee. , 1990, Journal of biomechanical engineering.

[27]  G. R. Pennock,et al.  An anatomy-based coordinate system for the description of the kinematic displacements in the human knee. , 1990, Journal of biomechanics.

[28]  C D Mote,et al.  A finite helical axis as a landmark for kinematic reference of the knee. , 1991, Journal of biomechanical engineering.

[29]  E. Wojtys,et al.  Quantitative analysis of the measuring capabilities of the KT-1000 knee ligament arthrometer , 1993, The American journal of sports medicine.

[30]  Herman J. Woltring,et al.  Representation and calculation of 3-D joint movement , 1991 .