Self-mixing interference effects in tunable diode laser absorption spectroscopy

We report the effects of self-mixing interference on gas detection using tunable diode laser spectroscopy. For very weak feedback, the laser diode output intensity gains a sinusoidal modulation analogous to that caused by low finesse etalons in the optical path. Our experiments show that self-mixing interference can arise from both specular reflections (e.g. cell windows) and diffuse reflections (e.g. Spectralon™ and retroreflective tape), potentially in a wider range of circumstances than etalon-induced interference. The form and magnitude of the modulation is shown to agree with theory. We have quantified the effect of these spurious signals on methane detection using wavelength modulation spectroscopy and discuss the implications for real gas detectors.

[1]  Sune Svanberg,et al.  Approach to optical interference fringes reduction in diode laser absorption spectroscopy , 2007 .

[2]  M. Sigrist Air monitoring by spectroscopic techniques , 1994 .

[3]  G. Giuliani,et al.  Self-mixing laser diode vibrometer , 2003 .

[4]  J. Dainty Laser speckle and related phenomena , 1975 .

[5]  J. A. Silver,et al.  Frequency modulation and wavelength modulation spectroscopies: comparison of experimental methods using a lead-salt diode laser. , 1992, Applied optics.

[6]  David A. Jackson,et al.  Optical fiber sensing with a low-finesse Fabry-Perot cavity. , 1992, Applied optics.

[7]  R. Tatam,et al.  Use of diffuse reflections in tunable diode laser absorption spectroscopy: implications of laser speckle for gas absorption measurements , 2008 .

[8]  B K Garside,et al.  Sensitivity limits of a tunable diode laser spectrometer, with application to the detection of NO(2) at the 100-ppt level. , 1980, Applied optics.

[9]  T. Iguchi Modulation waveforms for second-harmonic detection with tunable diode lasers , 1986 .

[10]  Bruno Toulouse,et al.  A low-cost medium-resolution rangefinder based on the self-mixing effect in a VCSEL , 2005, IEEE Transactions on Instrumentation and Measurement.

[11]  朝倉 利光,et al.  J.C.Dainty 編 : Laser Speckle and Related Phenomena, Springer-Verlag, Berlin and Heidelberg, 1975, 286ページ, 23.5×16cm, 15,170円, (Topics in Applied Physics, Vol.9) , 1976 .

[12]  Andrew G. Glen,et al.  APPL , 2001 .

[13]  Guido Giuliani,et al.  Laser diode self-mixing technique for sensing applications , 2002 .

[14]  Gang Li,et al.  The HITRAN 2008 molecular spectroscopic database , 2005 .

[15]  S. Saha Speckle interferometry , 1999, astro-ph/9910506.

[16]  J. A. Silver,et al.  Optical interference fringe reduction in laser absorption experiments. , 1988, Applied optics.

[17]  Daofu Han,et al.  Experiment observation of self-mixing interference in distributed feedback laser. , 2006, Optics express.