Cross-validation of a portable, six-degree-of-freedom load cell for use in lower-limb prosthetics research.

The iPecs load cell is a lightweight, six-degree-of-freedom force transducer designed to fit easily into an endoskeletal prosthesis via a universal mounting interface. Unlike earlier tethered systems, it is capable of wireless data transmission and on-board memory storage, which facilitate its use in both clinical and real-world settings. To date, however, the validity of the iPecs load cell has not been rigorously established, particularly for loading conditions that represent typical prosthesis use. The aim of this study was to assess the accuracy of an iPecs load cell during in situ human subject testing by cross-validating its force and moment measurements with those of a typical gait analysis laboratory. Specifically, the gait mechanics of a single person with transtibial amputation were simultaneously measured using an iPecs load cell, multiple floor-mounted force platforms, and a three-dimensional motion capture system. Overall, the forces and moments measured by the iPecs were highly correlated with those measured by the gait analysis laboratory (r>0.86) and RMSEs were less than 3.4% and 5.2% full scale output across all force and moment channels, respectively. Despite this favorable comparison, however, the results of a sensitivity analysis suggest that care should be taken to accurately identify the axes and instrumentation center of the load cell in situations where iPecs data will be interpreted in a coordinate system other than its own (e.g., inverse dynamics analysis).

[1]  M. Orendurff,et al.  Influence of malalignment on socket reaction moments during gait in amputees with transtibial prostheses. , 2013, Gait & posture.

[2]  Kerstin Hagberg,et al.  Kinetics of transfemoral amputees with osseointegrated fixation performing common activities of daily living. , 2007, Clinical biomechanics.

[3]  H J Stam,et al.  Techniques for measuring weight bearing during standing and walking. , 2003, Clinical biomechanics.

[4]  R Dumas,et al.  Loading applied on prosthetic knee of transfemoral amputee: comparison of inverse dynamics and direct measurements. , 2009, Gait & posture.

[5]  Ming Zhang,et al.  Effect of alignment changes on sagittal and coronal socket reaction moment interactions in transtibial prostheses. , 2013, Journal of biomechanics.

[6]  Frank Seehaus,et al.  Loads on the prosthesis-socket interface of above-knee amputees during normal gait: validation of a multi-body simulation. , 2013, Journal of biomechanics.

[7]  John H. Evans,et al.  Development and Preliminary Testing of a Device for the Direct Measurement of Forces and Moments in the Prosthetic Limb of Transfemoral Amputees during Activities of Daily Living , 2003 .

[8]  Laurent Frossard,et al.  Load applied on bone-anchored transfemoral prosthesis: characterization of a prosthesis-a pilot study. , 2013, Journal of rehabilitation research and development.

[9]  Steven Gray,et al.  Magnitude and variability of loading on the osseointegrated implant of transfemoral amputees during walking. , 2008, Medical engineering & physics.

[10]  Esteve Xavier Rifà Ros,et al.  FIELD, A. (2005). Discovering Statistics Using SPSS. London: SAGE Publications , 2006 .

[11]  Rickard Brånemark,et al.  Load on Osseointegrated Fixation of a Transfemoral Amputee During a Fall: Loading, Descent, Impact and Recovery Analysis , 2010, Prosthetics and orthotics international.

[12]  Dudley S. Childress,et al.  Problems associated with the use of inverse dynamics in prosthetic applications: An example using a polycentric prosthetic knee , 2005, Robotica.

[13]  S G Zachariah,et al.  A modular six-directional force sensor for prosthetic assessment: a technical note. , 1997, Journal of rehabilitation research and development.

[14]  David Alan Boone Investigation of socket reactions from transtibial prosthesis malalignment , 2005 .

[15]  Helco G van Keeken,et al.  Stabilizing moments of force on a prosthetic knee during stance in the first steps after gait initiation. , 2012, Medical engineering & physics.

[16]  T. Lu,et al.  A new device for in situ static and dynamic calibration of force platforms. , 2011, Gait & posture.

[17]  A. Hof On the interpretation of the support moment. , 2000, Gait & posture.

[18]  M Nietert,et al.  Loads in hip disarticulation prostheses during normal daily use , 1998, Prosthetics and orthotics international.

[19]  Ming Zhang,et al.  Effect of transtibial prosthesis alignment changes on out-of-plane socket reaction moments during walking in amputees. , 2012, Journal of biomechanics.

[20]  Wells Rp The projection of the ground reaction force as a predictor of internal joint moments. , 1981 .

[21]  M. Pearcy,et al.  Categorization of Activities of Daily Living of Lower Limb Amputees During Short-Term Use of a Portable Kinetic Recording System: A Preliminary Study , 2011 .

[22]  G. Wu,et al.  Limitations of quasi-static estimation of human joint loading during locomotion , 1996, Medical and Biological Engineering and Computing.

[23]  John Sullivan,et al.  Monitoring of the load regime applied on the osseointegrated fixation of a trans-femoral amputee: A tool for evidence-based practice , 2008, Prosthetics and orthotics international.

[24]  Laurent Frossard,et al.  Dynamic input to determine hip joint moments, power and work on the prosthetic limb of transfemoral amputees: ground reaction vs knee reaction , 2011, Prosthetics and orthotics international.

[25]  Toshiki Kobayashi,et al.  Effect of alignment changes on socket reaction moments during gait in transfemoral and knee-disarticulation prostheses: case series. , 2013, Journal of biomechanics.

[26]  Kartheek Yalamanchili,et al.  Transducer-based comparisons of the prosthetic feet used by transtibial amputees for different walking activities: a pilot study , 2012, Prosthetics and orthotics international.

[27]  A. Field Discovering statistics using SPSS for Windows. , 2000 .

[28]  Laurent Frossard,et al.  Apparatus for monitoring load bearing rehabilitation exercises of a transfemoral amputee fitted with an osseointegrated fixation: a proof-of-concept study. , 2010, Gait & posture.

[29]  N Berme,et al.  A Shorter Pylon Transducer for Measurement of Prosthetic Forces and Moments during Amputee Gait , 1975 .

[30]  Jack T Dennerlein,et al.  A force plate based method for the calibration of force/torque sensors. , 2012, Journal of biomechanics.

[31]  Kartheek Yalamanchili,et al.  Use of a load cell and force–moment curves to compare transverse plane moment loads on transtibial residual limbs: A preliminary investigation , 2014, Prosthetics and orthotics international.

[32]  Laurent Alain Frossard,et al.  Load on Osseointegrated Fixation of a Transfemoral Amputee during a Fall: Determination of the Time and Duration of Descent , 2010, Prosthetics and orthotics international.