Design and development of adapters for electromagnetic trackers to perform navigated laparoscopic radiofrequency ablation

BackgroundLaparoscopic radiofrequency ablation (RFA) is an accepted approach to treat unresectable liver tumours distinguishing itself from other techniques by combining minimal invasiveness and the advantages of a surgical approach. The major task of laparoscopic RFA is the accurate needle placement to achieve complete tumour ablation. The use of an ultrasound-based, laparoscopic online-navigation system could increase the safety and accuracy of punctures. To connect such a system with the laparoscopic ultrasound (LUS) transducer or the RFA needle especially designed adapters are needed. In this article we present our first experiences and prototypes for different sterilizable adapters for an electromagnetic navigation system for laparoscopic RFA.MethodsAll adapters were constructed with the help of a standard 3D CAD software. The adapters were built from medical stainless steel alloys and polyetherketone (PEEK). Prototypes were built in aluminium and polyoxymethilen (POM). We have designed and developed several adapters for the connection of electromagnetical tracking systems with different RFA needles and a laparoscopic ultrasound transducers.ResultsBased on earlier experiences of the initial version of the adapter, sterilisable adapters have been developed using biocompatible materials only. After short introduction, the adapters could be mounted to the laparoscopic ultrasound probe and the RFA needle under sterile conditions without any difficulties. Laboratory tests showed no disturbance of laparoscopic navigation system by the adapters. Anatomic landmarks in the liver could be safely reached. The adapters showed good feasibility, ergonomics, sterilizability and stability.ConclusionThe development of usable adapters is the prerequisite for accurate tracking of a RFA needle for laparoscopic navigation purposes as well as 3D navigated ultrasound data acquisition. We designed, tested and used different adapters for the use of a laparoscopic navigation system for the improvement of laparoscopic RFA.

[1]  H. Bruch,et al.  Laparoscopic ultrasound navigation in liver surgery: technical aspects and accuracy , 2006, Surgical Endoscopy And Other Interventional Techniques.

[2]  Achim Schweikard,et al.  Evaluation of an online navigation system for laparoscopic interventions in a perfused ex vivo artificial tumor model of the liver. , 2007, HPB : the official journal of the International Hepato Pancreato Biliary Association.

[3]  Technical aspects and feasibility of laparoscopic ultrasound navigation in radiofrequency ablation of unresectable hepatic malignancies. , 2007, Journal of laparoendoscopic & advanced surgical techniques. Part A.

[4]  A Schweikard,et al.  Prototype of an intraoperative navigation and documentation system for laparoscopic radiofrequency ablation: first experiences. , 2008, European journal of surgical oncology : the journal of the European Society of Surgical Oncology and the British Association of Surgical Oncology.

[5]  H. Bruch,et al.  Development of a perfused ex vivo tumor-mimic model for the training of laparoscopic radiofrequency ablation , 2007, Surgical Endoscopy.

[6]  Daniel B. Jones,et al.  Accuracy and effectiveness of laparoscopic vs open hepatic radiofrequency ablation , 2001, Surgical Endoscopy.

[7]  S. Rogers,et al.  Laparoscopic thermal ablation of hepatic neuroendocrine tumor metastases. , 1997, Surgery.

[8]  G. Cornalba,et al.  Safety and efficacy of laparoscopic radiofrequency of hepatocellular carcinoma in patients with liver cirrhosis , 2003, Surgical Endoscopy And Other Interventional Techniques.

[9]  S. Mulier,et al.  Complications of radiofrequency coagulation of liver tumours , 2002, The British journal of surgery.

[10]  M. Kleemann,et al.  Navigation in der Viszeralchirurgie , 2005, Visceral Medicine.