Electrical conductivity imaging using gradient Bz decomposition algorithm in magnetic resonance electrical impedance tomography (MREIT)

In magnetic resonance electrical impedance tomography (MREIT), we try to visualize cross-sectional conductivity (or resistivity) images of a subject. We inject electrical currents into the subject through surface electrodes and measure the z component Bz of the induced internal magnetic flux density using an MRI scanner. Here, z is the direction of the main magnetic field of the MRI scanner. We formulate the conductivity image reconstruction problem in MREIT from a careful analysis of the relationship between the injection current and the induced magnetic flux density Bz. Based on the novel mathematical formulation, we propose the gradient Bz decomposition algorithm to reconstruct conductivity images. This new algorithm needs to differentiate Bz only once in contrast to the previously developed harmonic Bz algorithm where the numerical computation of (inverted delta)2Bz is required. The new algorithm, therefore, has the important advantage of much improved noise tolerance. Numerical simulations with added random noise of realistic amounts show the feasibility of the algorithm in practical applications and also its robustness against measurement noise.

[1]  Byung Il Lee,et al.  J-substitution algorithm in magnetic resonance electrical impedance tomography (MREIT): phantom experiments for static resistivity images , 2002, IEEE Transactions on Medical Imaging.

[2]  Byung Il Lee,et al.  Conductivity and current density image reconstruction using harmonic Bz algorithm in magnetic resonance electrical impedance tomography. , 2003, Physics in medicine and biology.

[3]  Ohin Kwon,et al.  Magnetic resonance electrical impedance tomography (MREIT): simulation study of J-substitution algorithm , 2002, IEEE Transactions on Biomedical Engineering.

[4]  Byung Il Lee,et al.  Reconstruction of current density distributions in axially symmetric cylindrical sections using one component of magnetic flux density: computer simulation study. , 2003, Physiological measurement.

[5]  John G. Webster,et al.  Electrical Impedance Tomography , 1991 .

[6]  M. H. Cho,et al.  Static resistivity image of a cubic saline phantom in magnetic resonance electrical impedance tomography (MREIT). , 2003, Physiological measurement.

[7]  Ohin Kwon,et al.  Reconstruction of conductivity and current density images using only one component of magnetic field measurements , 2003, IEEE Transactions on Biomedical Engineering.

[8]  Y. Birgül,et al.  Use of the Magnetic Field Generated by the Internal Distribution of Injected Currents for Electrical Impedance Tomography (MR-EIT) , 1998 .

[9]  Eung Je Woo,et al.  Impedance tomography using internal current density distribution measured by nuclear magnetic resonance , 1994, Optics & Photonics.

[10]  B. F. Logan,et al.  The Fourier reconstruction of a head section , 1974 .

[11]  David Isaacson,et al.  Electrical Impedance Tomography , 2002, IEEE Trans. Medical Imaging.

[12]  R. Henkelman,et al.  Sensitivity of magnetic-resonance current-density imaging , 1992 .

[13]  B Murat,et al.  Current constrained voltage scaled reconstruction (CCVSR) algorithm for MR-EIT and its performance with different probing current patterns , 2003 .

[14]  K. Boone,et al.  Imaging with electricity: report of the European Concerted Action on Impedance Tomography. , 1997, Journal of medical engineering & technology.

[15]  Byung Il Lee,et al.  Three-dimensional forward solver and its performance analysis for magnetic resonance electrical impedance tomography (MREIT) using recessed electrodes. , 2003, Physics in medicine and biology.

[16]  William R B Lionheart,et al.  Uniqueness and reconstruction in magnetic resonance-electrical impedance tomography (MR-EIT). , 2003, Physiological measurement.

[17]  R M Henkelman,et al.  Measurement of nonuniform current density by magnetic resonance. , 1991, IEEE transactions on medical imaging.