History of extracorporeal circulation: the invention and modification of blood pumps.

The first roller pump was patented in 1855 by Porter and Bradley and was hand operated. A modification first named "surgical pump", designed and manufactured by E. E. Allen in 1887, was intended for direct blood transfusion. Truax, who also distributed and promoted the Allen pump with one roller, developed the first double roller pump in 1899. In the following decades, several researchers, including Beck, Van Allen, Bayliss and Müller as well as Henry and Jouvelet, refined the apparatus and recommended the use of roller pumps for blood transfusion and other applications. After further modifications made by DeBakey in 1934, and application of this pump in one of the first heart-lung machines constructed by Gibbon, DeBakey's name became inseparably attached to this type of pump. For perfusion experiments, an electrically powered roller pump was first used by Fleisch in 1935. Today, the roller pump is the most frequently used blood pump for cardiopulmonary bypass worldwide, having prevailed against the early pulsatile tube compression pumps and ventricular pumps. In recent years, centrifugal pumps have increasingly competed with roller pumps as systemic blood pumps for cardiopulmonary bypass and have become the preferred arterial pump in a variety of centers. Application of mechanical cardiac assistance has evolved from nonpulsatile roller pump support, followed by an era of pulsatile ventricular pumps to the rediscovery of the nonpulsatile flow mode with modern axial flow pumps.

[1]  G. Magovern,et al.  Use of a centrifugal pump without anticoagulants for postoperative left ventricular assist , 1985, World Journal of Surgery.

[2]  Abderhalden,et al.  Handbuch der biologischen Arbeitsmethoden , 1926, Nature.

[3]  A. Beck Zur Technik der Bluttransfusion , 1924, Klinische Wochenschrift.

[4]  J. Bock Ein Apparat zu Infusionsversuchen , 1907, Archiv für experimentelle Pathologie und Pharmakologie.

[5]  Scholten Über Bluttransfusion , 2005, Archiv für Gynäkologie.

[6]  C. Jacobj,et al.  Apparat zur Durchblutung isolirter überlebender Organe , 2005, Archiv für experimentelle Pathologie und Pharmakologie.

[7]  M. Turina,et al.  Optimized Veno-Venous Bypass with the Affinity Pump , 2001, ASAIO journal.

[8]  A. Stammers,et al.  Factors affecting perfusionists' decisions on equipment utilization: results of a United States survey. , 2000, The journal of extra-corporeal technology.

[9]  M. Lachat,et al.  Affinity pump system: a new peristaltic blood pump for cardiopulmonary bypass , 2000, Perfusion.

[10]  D. Sharpe,et al.  Haemolysis during cardiopulmonary bypass: an in vivo comparison of standard roller pumps, nonocclusive roller pumps and centrifugal pumps , 1999, Perfusion.

[11]  J. B. Riley,et al.  An under-occluded roller pump is less hemolytic than a centrifugal pump. , 1997, The journal of extra-corporeal technology.

[12]  R. Bartlett,et al.  Significant safety advantages gained with an improved pressure-regulated blood pump. , 1996, The journal of extra-corporeal technology.

[13]  E. Leonard,et al.  The effects of pressure and flow on hemolysis caused by Bio-Medicus centrifugal pumps and roller pumps. Guidelines for choosing a blood pump. , 1993, The Journal of thoracic and cardiovascular surgery.

[14]  S. Renolleau,et al.  Venovenous single lumen cannula extracorporeal lung support in neonates. A five year experience. , 1993, ASAIO journal (1992).

[15]  P. Pairolero,et al.  Circulatory support during crossclamping of the descending thoracic aorta. Evidence of improved organ perfusion. , 1990, The Journal of thoracic and cardiovascular surgery.

[16]  D. Payne,et al.  Arterial bypass of the descending thoracic aorta with the BioMedicus centrifugal pump. , 1987, The Annals of thoracic surgery.

[17]  D. Cooley Development of the roller pump for use in the cardiopulmonary bypass circuit. , 1987, Texas Heart Institute journal.

[18]  W. Dembitsky,et al.  Temporary extracorporeal support of the right ventricle. , 1986, The Journal of thoracic and cardiovascular surgery.

[19]  G. Zumbro,et al.  Mechanical assistance for biventricular failure following coronary bypass operation and heart transplantation. , 1985, The Journal of heart transplantation.

[20]  G. Magovern,et al.  Use of the BioMedicus centrifugal pump in traumatic tears of the thoracic aorta. , 1984, The Annals of thoracic surgery.

[21]  F. Loop,et al.  Clinical results of mechanical support of the failing left ventricle. , 1982, The Journal of thoracic and cardiovascular surgery.

[22]  D. Pennington,et al.  Clinical experience with a centrifugal pump ventricular assist device. , 1982, Transactions - American Society for Artificial Internal Organs.

[23]  Y Nosé,et al.  Initial clinical experience with a new temporary left ventricular assist device. , 1980, The Annals of thoracic surgery.

[24]  E. Bernstein A Centrifugal Pump for Circulatory Assistance , 1979 .

[25]  K. Taylor,et al.  Comparative studies of pulsatile and nonpulsatile flow during cardiopulmonary bypass. III. Response of anterior pituitary gland to thyrotropin-releasing hormone. , 1978, The Journal of thoracic and cardiovascular surgery.

[26]  J. Grant,et al.  Comparative studies of pulsatile and nonpulsatile flow during cardiopulmonary bypass. II. The effects on adrenal secretion of cortisol. , 1978, The Journal of thoracic and cardiovascular surgery.

[27]  K. Taylor,et al.  Comparative studies of pulsatile and nonpulsatile flow during cardiopulmonary bypass. I. Pulsatile system employed and its hematologic effects. , 1978, Journal of Thoracic and Cardiovascular Surgery.

[28]  Gille Jp,et al.  In vitro study of hemolysis induced by flow-regulated and pressure-dependent flow pumps. , 1976 .

[29]  R. Stahl,et al.  In vitro study of hemolysis induced by flow-regulated and pressure-dependent flow pumps. , 1976, Medical Progress Through Technology.

[30]  E. Bernstein,et al.  Twenty‐four Hour Left Ventricular BYpass with a Centrifugal Blood Pump , 1975, Annals of Surgery.

[31]  G L Hallman,et al.  Orthotopic cardiac prosthesis for two-staged cardiac replacement. , 1969, The American journal of cardiology.

[32]  H. Kletschka,et al.  Artificial heart. I. Application of nonpulsatile force-vortex principle. , 1968, Minnesota medicine.

[33]  D. Harken Mechanical devices to assist the failing heart , 1967 .

[34]  F. Spencer,et al.  ASSISTED CIRCULATION FOR CARDIAC FAILURE FOLLOWING INTRACARDIAC SURGERY WITH CARDIOPULMONARY BYPASS. , 1965, The Journal of thoracic and cardiovascular surgery.

[35]  Saxton Ga,et al.  An ideal heart pump with hydrodynamic characteristics analogous to the mammalian heart. , 1960 .

[36]  S. Weitzner,et al.  The use of the heart-lung machine in selected cases of acute myocardial infarction. , 1957, Surgical forum.

[37]  Wood Eh,et al.  Apparatus of the Gibbon type for mechanical bypass of the heart and lungs; preliminary report. , 1955 .

[38]  C. R. Lam Henry Ford Hospital International Symposium on cardiovascular surgery : studies in physiology, diagnosis and techniques , 1955 .

[39]  J. Kirklin,et al.  Apparatus of the Gibbon type for mechanical bypass of the heart and lungs; preliminary report. , 1955, Proceedings of the staff meetings. Mayo Clinic.

[40]  J. H. Gibbon,et al.  Application of a mechanical heart and lung apparatus to cardiac surgery. , 1954, Minnesota medicine.

[41]  J. H. Gibbon,et al.  Recent advances in the development of a mechanical heart and lung apparatus. , 1951, Annals of surgery.

[42]  R. M. Nelson,et al.  Development of a pump-oxygenator to replace the heart and lungs; an apparatus applicable to human patients, and application to one case. , 1951, Annals of surgery.

[43]  P. Salisbury Apparatus for cross transfusion. , 1949, Proceedings of the Society for Experimental Biology and Medicine. Society for Experimental Biology and Medicine.

[44]  V. Björk An artificial heart or cardiopulmonary machine; performance in animals. , 1948 .

[45]  A. S. Wiener,et al.  An Agglutinable Factor in Human Blood Recognized by Immune Sera for Rhesus Blood , 1940 .

[46]  J. H. Gibbon ARTIFICIAL MAINTENANCE OF CIRCULATION DURING EXPERIMENTAL OCCLUSION OF PULMONARY ARTERY , 1937 .

[47]  Michael E. DeBakey,et al.  A Simple Continuous-Flow Blood Transfusion Instrument , 1934 .

[48]  C. V. Allen,et al.  A PUMP FOR CLINICAL AND LABORATORY PURPOSES WHICH EMPLOYS THE MILKING PRINCIPLE , 1932 .

[49]  L. E. Bayliss,et al.  A simple high-speed rotary pump , 1928 .

[50]  H. Dale,et al.  A double perfusion‐pump , 1928, The Journal of physiology.

[51]  R. Gesell ON THE RELATION OF PULSE PRESSURE TO RENAL SECRETION , 1913 .

[52]  A. Inokuty,et al.  ON CENTRIFUGAL PUMPS , 1913 .

[53]  D. Hooker A STUDY OF THE ISOLATED KIDNEY.—THE INFLUENCE OF PULSE PRESSURE UPON RENAL FUNCTION , 1910 .

[54]  W. Gross,et al.  Zur Kenntnis des Tyrosinabbaus in der künstlich durchbluteten Leber. , 2022 .

[55]  C. J. Martin,et al.  The action of anæsthetic quantities of chloroform upon the blood vessels of the bowel and kidney; with an account of an artificial circulation apparatus , 1905, Journal of Physiology.

[56]  T. G. Brodie The perfusion of surviving organs , 1903, The Journal of physiology.

[57]  K. Landsteiner,et al.  Ueber Agglutinationserscheinungen normalen menschlichen Blutes , 1901 .

[58]  J. F. Meckel Archiv für Anatomie und Physiologie , 1826 .