Analytical, Numerical and Experimental Study of a Horizontal Electrothermal MEMS Microgripper for the Deformability Characterisation of Human Red Blood Cells

Microgrippers are typical microelectromechanical systems (MEMS) that are widely used for micromanipulation and microassembly in both biological and micromanufacturing fields. This paper presents the design, modelling, fabrication and experimental testing of an electrothermal microgripper based on a ‘hot and cold arm’ actuator design that is suitable for the deformability characterisation of human red blood cells (RBCs). The analysis of the mechanical properties of human RBCs is of great interest in the field of medicine as pathological alterations in the deformability characteristics of RBCs have been linked to a number of diseases. The study of the microgripper’s steady-state performance is initially carried out by the development of a lumped analytical model, followed by a numerical model established in CoventorWare® (Coventor, Inc., Cary, NC, USA) using multiphysics finite element analysis. Both analytical and numerical models are based on an electothermomechanical analysis, and take into account the internal heat generation due to the applied potential, as well as conduction heat losses through both the anchor pads and the air gap to the substrate. The models are used to investigate key factors of the actuator’s performance including temperature distribution, deflection and stresses based on an elastic analysis of structures. Results show that analytical and numerical values for temperature and deflection are in good agreement. The analytical and computational models are then validated experimentally using a polysilicon microgripper fabricated by the standard surface micromachining process, PolyMUMPs™ (Durham, NC, USA). The microgripper’s actuation is characterised at atmospheric pressure by optical microscopy studies. Experimental results for the deflection of the microgripper arm tips are found to be in good agreement with the analytical and numerical results, with process-induced variations and the non-linear temperature dependence of the material properties accounting for the slight discrepancies observed. The microgripper is shown to actuate to a maximum opening displacement of 9 μm at an applied voltage of 3 V, thus being in line with the design requirement of an approximate opening of 8 μm for securing and characterising a RBC.

[1]  G. Tomaiuolo Biomechanical properties of red blood cells in health and disease towards microfluidics. , 2014, Biomicrofluidics.

[2]  Nicola Pio Belfiore,et al.  A Comprehensive Survey on Microgrippers Design: Operational Strategy , 2017 .

[3]  Yu Sun,et al.  Elastic and viscoelastic characterization of microcapsules for drug delivery using a force-feedback MEMS microgripper , 2009, Biomedical microdevices.

[4]  T. Christenson,et al.  Thermo-magnetic metal flexure actuators , 1992, Technical Digest IEEE Solid-State Sensor and Actuator Workshop.

[5]  Ted Hubbard,et al.  Heat transfer analysis and optimization of two-beam microelectromechanical thermal actuators , 2002 .

[6]  Amir Khajepour,et al.  Modeling of two-hot-arm horizontal thermal actuator , 2003 .

[7]  Yu Sun,et al.  Nanonewton force-controlled manipulation of biological cells using a monolithic MEMS microgripper with two-axis force feedback , 2008 .

[8]  R. Muller,et al.  Silicon-processed overhanging microgripper , 1992 .

[9]  R. Aigner,et al.  Fracture strength and fatigue of polysilicon determined by a novel thermal actuator [MEMS] , 2000 .

[10]  Zhaopeng Chen,et al.  A multipurpose electrothermal microgripper for biological micro-manipulation , 2013 .

[11]  Yu Sun,et al.  Autonomous Robotic Pick-and-Place of Microobjects , 2010, IEEE Transactions on Robotics.

[12]  John B. Kennedy Elastic analysis of structures : classical and matrix methods / John B. Kennedy, Murty K.S. Madugula , 1990 .

[13]  Nicola Pio Belfiore,et al.  A Comprehensive Survey on Microgrippers Design: Mechanical Structure , 2017 .

[14]  Qingsong Xu,et al.  A review on actuation and sensing techniques for MEMS-based microgrippers , 2017 .

[15]  Qingsong Xu,et al.  MEMS Microgripper Actuators and Sensors: The State-of-the-Art Survey , 2013 .

[16]  R. A. Coutu,et al.  Thermal Management Using MEMS Bimorph Cantilever Beams , 2016 .

[17]  P. Dario,et al.  Design and fabrication of an electrostatically driven microgripper for blood vessel manipulation , 2006 .

[18]  N. Chronis,et al.  Electrothermally activated SU-8 microgripper for single cell manipulation in solution , 2005, Journal of Microelectromechanical Systems.

[19]  Mu Chiao,et al.  Electrothermal responses of lineshape microstructures , 1996 .

[20]  Ivo W. Rangelow,et al.  Thermally driven microgripper as a tool for micro assembly , 2006 .

[21]  Qingsong Xu,et al.  Design, Fabrication, and Testing of an MEMS Microgripper With Dual-Axis Force Sensor , 2015, IEEE Sensors Journal.

[22]  M. Verotti,et al.  Compliance Synthesis of CSFH MEMS-Based Microgrippers , 2017 .

[23]  N. Nguyen,et al.  A polymeric microgripper with integrated thermal actuators , 2004 .

[24]  Alvise Bagolini,et al.  New MEMS Tweezers for the Viscoelastic Characterization of Soft Materials at the Microscale , 2017, Micromachines.

[25]  Alvise Bagolini,et al.  Fabrication of Novel MEMS Microgrippers by Deep Reactive Ion Etching With Metal Hard Mask , 2017, Journal of Microelectromechanical Systems.