Simultaneous determination of three organophosphorus pesticides residues in vegetables using continuous-flow chemiluminescence with artificial neural network calibration.

In this article, a continuous-flow chemiluminescence (CL) system with artificial neural network calibration is proposed for simultaneous determination of three organophosphorus pesiticides residues. This method is based on the fact that organophosphorus pesticides can be decomposed into orthophosphate with potassium peroxodisulphate as oxidant under ultraviolet radiation and that the decomposing kinetic characteristics of the organophosphorus pesticides with different molecular structure are significantly different. The produced orthophosphate can react with molybdate and vanadate to form the vanadomolybdophosphoric heteropoly acid, which can oxidize luminol to produce intense CL emission. The CL intensity of the solution was measured and recorded every 2s in the range of 0-250s. The obtained data were processed chemometrically by use of a three-layered feed-forward artificial neural network trained by back-propagation learning algorithm, in which input node, hidden node and output nodes were 65, 21 and 3, respectively. The proposed multi-residue analysis method was successfully applied to the simultaneous determination of the three organophosphorus pesticides residue in some vegetables samples.

[1]  P. Marquet,et al.  Simultaneous determination of six dialkylphosphates in urine by liquid chromatography tandem mass spectrometry. , 2006, Journal of chromatography. B, Analytical technologies in the biomedical and life sciences.

[2]  Y. Jin,et al.  Plant tissue-based chemiluminescence flow biosensor for glycolic acid. , 2001, Analytical chemistry.

[3]  S. R. Crouch,et al.  Multicomponent Kinetic Methods , 1993 .

[4]  Garry A. Rechnitz,et al.  Mediated Bioelectrocatalytic Determination of Organophosphorus Pesticides with a Tyrosinase-Based Oxygen Biosensor , 1998 .

[5]  Antonio González-Casado,et al.  Analysis of pesticides by chemiluminescence detection in the liquid phase , 2005 .

[6]  Shang-da Huang,et al.  Determination of ethoprop, diazinon, disulfoton and fenthion using dynamic hollow fiber-protected liquid-phase microextraction coupled with gas chromatography-mass spectrometry. , 2006, Talanta.

[7]  Serge Kokot,et al.  Simultaneous Spectrophotometric Determination of Maltol, Ethyl Maltol, Vanillin and Ethyl Vanillin in Foods by Multivariate Calibration and Artificial Neural Networks. , 2005 .

[8]  A. Safavi,et al.  Simultaneous kinetic determination of sulfite and sulfide using artificial neural networks. , 2004, Talanta.

[9]  J Wang,et al.  Development of a luminol-based chemiluminescence flow-injection method for the determination of dichlorvos pesticide. , 2001, Talanta.

[10]  M. Rezaee,et al.  Determination of organophosphorus pesticides in water samples by single drop microextraction and gas chromatography-flame photometric detector. , 2006, Journal of chromatography. A.

[11]  F. Millero,et al.  Rates and Mechanism of Fe(II) Oxidation at Nanomolar Total Iron Concentrations. , 1995, Environmental science & technology.

[12]  Birks,et al.  Trace analysis of phosphorus in water by sorption preconcentration and luminol chemiluminescence , 2000, Analytical chemistry.

[13]  S. Ventura,et al.  Multicomponent kinetic determinations using artificial neural networks. , 1995, Analytical chemistry.

[14]  V. Tomás,et al.  High-performance liquid chromatographic assay of phosphate and organophosphorus pesticides using a post-column photochemical reaction and fluorimetric detection , 2005 .

[15]  Jia-Zhong Zhang,et al.  Optimization of performance and minimization of silicate interference in continuous flow phosphate analysis. , 1999, Talanta.

[16]  C. N. Reilley,et al.  Kinetic Analysis of Mixtures by the Method of Proportional Equations. , 1962 .

[17]  Huangxian Ju,et al.  Binding of acetylcholinesterase to multiwall carbon nanotube-cross-linked chitosan composite for flow-injection amperometric detection of an organophosphorous insecticide. , 2006, Chemistry.

[18]  D. Lee,et al.  Determination of organophosphorus pesticides in wheat flour by supercritical fluid extraction and gas chromatography with nitrogen-phosphorus detection. , 1998, Journal of chromatography. A.

[19]  P. Moris,et al.  Chemiluminescence assays of organophosphorus and carbamate pesticides , 1995 .

[20]  Gordon A Anderson,et al.  Use of artificial neural networks for the accurate prediction of peptide liquid chromatography elution times in proteome analyses. , 2003, Analytical chemistry.

[21]  Qingde Su,et al.  Selective solid-phase extraction using molecularly imprinted polymer for the analysis of polar organophosphorus pesticides in water and soil samples. , 2005, Journal of chromatography. A.

[22]  Jianxiu Du,et al.  Determination of parathion residues in rice samples using a flow injection chemiluminescence method. , 2003, Luminescence : the journal of biological and chemical luminescence.

[23]  Song Zhang,et al.  A mediator-free screen-printed amperometric biosensor for screening of organophosphorus pesticides with flow-injection analysis (FIA) system. , 2006, Talanta.

[24]  Paul J. Worsfold,et al.  Analytical applications of liquid-phase chemiluminescence , 1992 .

[25]  Baoxin Li,et al.  Flow-injection chemiluminescence simultaneous determination of cobalt(II) and copper(II) using partial least squares calibration. , 2006, Talanta.

[26]  Ali Benvidi,et al.  Simultaneous determination of copper, lead and cadmium by cathodic adsorptive stripping voltammetry using artificial neural network , 2006 .

[27]  Flow-injection spectrofluorimetric determination of dissolved inorganic and organic phosphorus in waters using on-line photo-oxidation , 2001 .

[28]  Bin Hu,et al.  Optimization of a single-drop microextraction procedure for the determination of organophosphorus pesticides in water and fruit juice with gas chromatography-flame photometric detection. , 2006, Talanta.

[29]  Z. S. Ferrera,et al.  Micellar extraction of organophosphorus pesticides and their determination by liquid chromatography , 2004 .

[30]  Baoxin Li,et al.  Simultaneous determination of rifampicin and isoniazid by continuous-flow chemiluminescence with artificial neural network calibration , 2005, Analytical and bioanalytical chemistry.