A passive design strategy for a horizontal ground source heat pump pipe operation optimization with a non-homogeneous soil profile

Abstract The effectiveness of a non-homogeneous soil profile for horizontal ground source heat pumps (GSHPs), defined as natural backfill with an intermediate layer of material having different thermal characteristics, is investigated. Steps toward development of a comprehensive model to consider the effects of the non-homogeneous layer are described. The developed model is utilized successfully in conjunction with a genetic algorithm (GA) search method to obtain the optimized operational parameters for a GSHP in three different climate conditions. A properly sized and engineered non-homogeneous soil profile demonstrated the potential to increase the energy extraction/dissipation rates from/to the ground to a significant level. The potential benefit of a recycled product, Tire Derived Aggregate (TDA), as an insulating non-homogeneous layer is assessed. TDA is demonstrated to be more effective in the cold climate (Buffalo) by increasing the energy extraction rates from the ground approximately 15% annually. TDA's effectiveness is less pronounced in a relatively moderate climate (Dallas) by increasing the energy extraction rates from the ground about 4% annually. For the cooling only scenario (Miami), a high conductive intermediate layer of saturated sand exhibited greater potential to increase the energy dissipation to the ground.

[1]  F. Ling,et al.  A numerical model for surface energy balance and thermal regime of the active layer and permafrost containing unfrozen water , 2004 .

[2]  Hakan Demir,et al.  Determination of Optimum Design Parameters of Horizontal Parallel Pipe and Vertical U-Tube Ground Heat Exchangers , 2009 .

[3]  Tainzhen Hong,et al.  Comparison of energy efficiency between variable refrigerant flow systems and ground source heat pump systems , 2009 .

[4]  Sepehr Sanaye,et al.  Horizontal ground coupled heat pump: Thermal-economic modeling and optimization , 2010 .

[5]  Sepehr Sanaye,et al.  Thermal-economic modeling and optimization of vertical ground-coupled heat pump , 2009 .

[6]  Chen Xi,et al.  Long term operation of a solar assisted ground coupled heat pump system for space heating and domestic hot water , 2011 .

[7]  Anastassios M. Stamatelos,et al.  Optimization of thermal performance of a building with ground source heat pump system , 2007 .

[8]  Gary F. Dargush,et al.  A New Control Strategy to Improve the Ground Source Heat Pump’s Efficiency With a Recycled Product , 2012 .

[9]  Sanjeev Jain,et al.  Energy savings in a building using regenerative evaporative cooling , 2011 .

[10]  Majid Amidpour,et al.  Multi-objective optimization of a vertical ground source heat pump using evolutionary algorithm , 2009 .

[11]  Hatef Madani,et al.  Capacity control in ground source heat pump systems Part I : modeling and simulation , 2011 .

[12]  J. M. Pinazo,et al.  Performance analysis of an air conditioning system driven by natural gas , 2003 .

[13]  Savvas A. Tassou,et al.  VARIABLE-SPEED CAPACITY CONTROL IN REFRIGERATION SYSTEMS , 1996 .

[14]  G. Sabnis,et al.  PHYSICAL AND CHEMICAL PROPERTIES OF RECYCLED TIRE SHREDS FOR USE IN CONSTRUCTION , 2003 .

[15]  S. Jain,et al.  Transient Characteristics of Split Air-Conditioning Systems Using R-22 and R-410A as Refrigerants , 2009 .

[16]  Robert G. Fleagle,et al.  An Introduction to Atmospheric Physics , 1980 .

[17]  Yi Jiang,et al.  Dynamical building simulation: A low order model for thermal bridges losses , 2008 .

[18]  Gary F. Dargush,et al.  Ground source heat pump pipe performance with Tire Derived Aggregate , 2012 .

[19]  Sadik Kakaç,et al.  Heat Exchangers: Selection, Rating, and Thermal Design, Second Edition , 1997 .

[20]  Goldberg,et al.  Genetic algorithms , 1993, Robust Control Systems with Genetic Algorithms.

[21]  Farraj F. Al-ajmi,et al.  Simulation of energy consumption for Kuwaiti domestic buildings , 2008 .

[22]  Ryozo Ooka,et al.  Development of a numerical model to predict heat exchange rates for a ground-source heat pump system , 2008 .

[23]  Phillip John Jones,et al.  Case study of zero energy house design in UK , 2009 .

[24]  Ahmet Koyun,et al.  Experimental study of heat transfer of buried finned pipe for ground source heat pump applications , 2009 .

[25]  Dana N. Humphrey,et al.  Field Trial of Tire Shreds as Insulation for Paved Roads , 1999 .

[26]  B. Perers,et al.  Optimization of systems with the combination of ground-source heat pump and solar collectors in dwellings , 2010 .

[27]  Satish V. Ukkusuri,et al.  Optimizing the design of a solar cooling system using central composite design techniques , 2011 .

[28]  David E. Goldberg,et al.  Genetic Algorithms in Search Optimization and Machine Learning , 1988 .

[29]  Dahai Zhang,et al.  Modelling of the Net Zero Energy Town House in Toronto Using TRNSYS, and an Analysis of the Impact Using Thermal Mass , 2008 .

[30]  Dorothy K. Hall,et al.  An energy-balance model of lake-ice evolution , 1995 .

[31]  Ruzhu Wang,et al.  Energy simulation in the variable refrigerant flow air-conditioning system under cooling conditions , 2007 .

[32]  D. E. Goldberg,et al.  Genetic Algorithms in Search , 1989 .

[33]  T. Kusuda,et al.  EARTH TEMPERATURE AND THERMAL DIFFUSIVITY AT SELECTED STATIONS IN THE UNITED STATES , 1965 .

[34]  Galip Temir,et al.  Heat transfer of horizontal parallel pipe ground heat exchanger and experimental verification , 2009 .

[35]  Hatef Madani,et al.  Capacity control in ground source heat pump systems part II: Comparative analysis between on/off controlled and variable capacity systems , 2011 .

[36]  J. Zarling,et al.  THERMAL CONDUCTIVITY OF RECYCLED TIRE RUBBER TO BE USED AS INSULATING FILL BENEATH ROADWAYS , 1995 .

[37]  Melanie Mitchell,et al.  An introduction to genetic algorithms , 1996 .

[38]  K. F. Fong,et al.  Comparison of annual energy performances with different ventilation methods for temperature and humi , 2011 .