In-Line Monitoring of Polymer Processing. II: Spectral Data Analysis

The objective of this work was to examine the application of various multivariate methods to determine the composition of a flowing, molten, immiscible, polyethylene–polypropylene blend from near-infrared spectra. These spectra were acquired during processing by monitoring the melt with a fiber-optic-assisted in-line spectrometer. Undesired differences in spectra obtained from identical compositions were attributed to additive and multiplicative light scattering effects. Duplicate blend composition data were obtained over a range of 0 to 100% polyethylene. On the basis of previously published approaches, three data preprocessing methods were investigated: second derivative of absorbance with respect to wavelength (d2), multiplicative scatter correction (MSC), and a combination consisting of MSC followed by d2. The latter method was shown to substantially improve superposition of spectra and principal component analysis (PCA) scores. Also, fewer latent variables were required. The continuum regression (CR) approach, a method that encompasses ordinary least squares (OLS), partial least squares (PLS), and principle component regression (PCR) models, was then implemented and provided the best prediction model as one based on characteristics between those of PLS and OLS models.

[1]  Tormod Næs,et al.  Comparison of prediction methods for multicollinear data , 1985 .

[2]  Paul Geladi,et al.  Principal Component Analysis , 1987, Comprehensive Chemometrics.

[3]  B. M. Wise,et al.  Canonical partial least squares and continuum power regression , 2001 .

[4]  D. W. Osten,et al.  Selection of optimal regression models via cross‐validation , 1988 .

[5]  Onno E. de Noord,et al.  The influence of data preprocessing on the robustness and parsimony of multivariate calibration models , 1994 .

[6]  Barry M. Wise,et al.  Identification of finite impulse response models with continuum regression , 1993 .

[7]  M. Hansen,et al.  In‐line monitoring of molten polymers: Near infrared spectroscopy, robust probes, and rapid data analysis , 1994 .

[8]  Stephen T. Balke,et al.  In-Line Near-Infrared Monitoring of Polymer Processing. Part I: Process/Monitor Interface Development , 1999 .

[9]  John R. Morrey,et al.  On determining spectral peak positions from composite spectra with a digital computer , 1968 .

[10]  Charles E. Miller,et al.  Near-Infrared Spectroscopy of Synthetic Polymers , 1991 .

[11]  Dominic P. Searson,et al.  Nonlinear continuum regression: an evolutionary approach , 2000 .

[12]  Jerry Workman,et al.  Applied Spectroscopy: A Compact Reference for Practitioners , 1998 .

[13]  P. Williams,et al.  Near-Infrared Technology in the Agricultural and Food Industries , 1987 .

[14]  Anders Björkström,et al.  A Generalized View on Continuum Regression , 1999 .

[15]  B. Kowalski,et al.  Partial least-squares regression: a tutorial , 1986 .

[16]  Luis A. Sarabia,et al.  Using continuum regression for quantitative analysis with overlapping signals obtained by differential pulse polarography , 1996 .