New configuration of high-power inverter drives
暂无分享,去创建一个
New configurations for high-power and high performance drives suitable for steel rolling mill drives are presented. Three-level inverters using 6 inch, 6 kV, 6 kA GTOs, can deliver 10000 kVA output. But in case of drives rated more than several thousands of kW, this capacity is still insufficient. Usually, two three-level inverters are then combined using bulky, expensive inter-phase reactors. To meet these problems, a new configuration using the wound rotor induction motor and two inverters is proposed. In this configuration, the outputs of the two inverters are combined electromechanically in the machine; then novel features suitable for high-power drives can be obtained.
[1] Masato Koyama,et al. A New PWM Method of a Three-Level Inverter Considering Minimum Pulse Width and Neutral Voltage Balance Control , 1993 .
[2] T. Kawabata,et al. Space voltage vector-based new PWM method for large capacity three-level GTO inverter , 1992, Proceedings of the 1992 International Conference on Industrial Electronics, Control, Instrumentation, and Automation.
[3] Toshiyuki Fujii,et al. 3 level GTO converter-inverter pair system for large capacity induction motor drive , 1993 .