Motion Planning and Robust Control for the Endovascular Navigation of a Microrobot

Microrobots show great targeted-delivery potential in precision medicine. This article presents the use of a model-free approach to the navigation control of a microrobot in the cardiovascular environment. With the proposed approach, the microrobot can adapt to the non-Newton behavior of blood and environmental disturbances when it moves in blood vessels without knowledge of blood-velocity distribution. The referred trajectory of the navigated microrobot is generated by using a breadth-first search and genetic algorithm, aiming to minimize the energy consumption. The proposed navigation controller combines sliding mode control, backstepping control, and disturbance compensation. A high-gain extended state observer is designed to estimate and reject the uncertainties of model parameters and environmental disturbances. Simulations are performed to demonstrate the effectiveness of the proposed approach in a small artery compared with other control methods.

[1]  Sylvain Martel,et al.  Real-Time MRI-Based Control of a Ferromagnetic Core for Endovascular Navigation , 2008, IEEE Transactions on Biomedical Engineering.

[2]  Chi K. Tse,et al.  A Constraint-Aware Heuristic Path Planner for Finding Energy-Efficient Paths on Uneven Terrains , 2015, IEEE Transactions on Industrial Informatics.

[3]  Mincheng Zhong,et al.  Trapping red blood cells in living animals using optical tweezers , 2013, Nature Communications.

[4]  Baijie Qiao,et al.  A force identification method using cubic B-spline scaling functions , 2015 .

[5]  Shihua Li,et al.  Speed Control for PMSM Servo System Using Predictive Functional Control and Extended State Observer , 2012, IEEE Transactions on Industrial Electronics.

[6]  Chenguang Yang,et al.  Integral Sliding Mode Control: Performance, Modification, and Improvement , 2018, IEEE Transactions on Industrial Informatics.

[7]  Antoine Ferreira,et al.  Endovascular Magnetically Guided Robots: Navigation Modeling and Optimization , 2012, IEEE Transactions on Biomedical Engineering.

[8]  Yacine Amirat,et al.  Modeling and Control of a Continuum Style Microrobot for Endovascular Surgery , 2011, IEEE Transactions on Robotics.

[9]  Metin Sitti,et al.  Modeling and Experimental Characterization of an Untethered Magnetic Micro-Robot , 2009, Int. J. Robotics Res..

[10]  C. Sawyers,et al.  Targeted cancer therapy , 2004, Nature.

[11]  Luc Dupré,et al.  Robustness Assessment of 1-D Electron Paramagnetic Resonance for Improved Magnetic Nanoparticle Reconstructions , 2015, IEEE Transactions on Biomedical Engineering.

[12]  A. Schenk,et al.  Intrahepatic Vascular Anatomy in Rats and Mice—Variations and Surgical Implications , 2015, PloS one.

[13]  Antoine Ferreira,et al.  Simulation and Planning of a Magnetically Actuated Microrobot Navigating in the Arteries , 2013, IEEE Transactions on Biomedical Engineering.

[14]  S. Martel,et al.  Use of 3D Potential Field and an Enhanced Breadth-first Search Algorithms for the Path Planning of Microdevices Propelled in the Cardiovascular System , 2005, 2005 IEEE Engineering in Medicine and Biology 27th Annual Conference.

[15]  J. Karp,et al.  Nanocarriers as an Emerging Platform for Cancer Therapy , 2022 .

[16]  A. Ferreira,et al.  Untethered microrobot control in fluidic environment using magnetic gradients , 2012, 2012 International Symposium on Optomechatronic Technologies (ISOT 2012).

[17]  J. Kettenbach,et al.  Drug-Loaded Microspheres for the Treatment of Liver Cancer: Review of Current Results , 2008, CardioVascular and Interventional Radiology.

[18]  Toshio Fukuda,et al.  Grand Challenges in Bioengineered Nanorobotics for Cancer Therapy , 2013, IEEE Transactions on Biomedical Engineering.

[19]  B. Nelson,et al.  Shape-switching microrobots for medical applications: the influence of shape in drug delivery and locomotion. , 2015, ACS applied materials & interfaces.

[20]  Yong Wang,et al.  Modeling and Control of Single-Cell Migration Induced by a Chemoattractant-Loaded Microbead , 2019, IEEE Transactions on Cybernetics.

[21]  Antoine Ferreira,et al.  Control of a magnetic microrobot navigating in microfluidic arterial bifurcations through pulsatile and viscous flow , 2012, 2012 IEEE/RSJ International Conference on Intelligent Robots and Systems.

[22]  Jindong Tan,et al.  Dynamics Modeling and Analysis of a Swimming Microrobot for Controlled Drug Delivery , 2006, IEEE Transactions on Automation Science and Engineering.

[23]  Ran Wang,et al.  Development of a magnetic microrobot for carrying and delivering targeted cells , 2018, Science Robotics.

[24]  Antoine Ferreira,et al.  Guidelines for the Design of Magnetic Nanorobots to Cross the Blood–Brain Barrier , 2014, IEEE Transactions on Robotics.

[25]  R. Vito,et al.  Blood vessel constitutive models-1995-2002. , 2003, Annual review of biomedical engineering.

[26]  Carlos García-Rodriguez,et al.  Robust backstepping tracking controller for low speed PMSM positioning system: Design, analysis, and implementation , 2015, ICIT.

[27]  Dongfang Li,et al.  Gradient-Enhanced Electromagnetic Actuation System With a New Core Shape Design for Microrobot Manipulation , 2020, IEEE Transactions on Industrial Electronics.