Determination of scattering in intraocular lenses by spectrophotometric measurements

Abstract. This study presents a method for measuring scattering in explanted intraocular lenses (IOLs). Currently, determining scattering in IOLs is usually performed by Scheimpflug cameras and the results are expressed in the units used by this apparatus. The method we propose uses a spectrophotometer and this makes it possible to measure the total transmission of the IOL by using an integrating sphere; the direct transmission is determined by the double-beam mode. The difference between these two transmissions gives a value of the scattering in percentage values of light lost. In addition, by obtaining the spectral transmission curve, information about the most scattered wavelengths is also obtained. The IOL power introduces errors when directly measured, particularly with high powers. This problem can be overcome if a tailor-made cuvette is used that shortens the distance between the IOL and the condensing lens of the spectrophotometer when the IOL powers are below 24 diopters. We checked the effectiveness of this method by measuring the scattering of three explanted IOLs from cornea donors. This method, however, does not make it possible to ascertain whether the scattering measured is caused by surface light scattering or internal light scattering.

[1]  Edward A. Boettner,et al.  Transmission of the Ocular Media , 1962 .

[2]  M. C. García-Domene,et al.  Spectral transmittance of intraocular lenses under natural and artificial illumination: criteria analysis for choosing a suitable filter. , 2011, Ophthalmology.

[3]  J. Colin,et al.  Limitations of Scheimpflug photography in quantifying glistenings. , 2009, Journal of cataract and refractive surgery.

[4]  N. Mamalis,et al.  Role of silicon contamination on calcification of hydrophilic acrylic intraocular lenses. , 2006, American journal of ophthalmology.

[5]  Lisa Toto,et al.  Glistenings in foldable intraocular lenses , 2002, Journal of cataract and refractive surgery.

[6]  A. Felipe,et al.  Spectral transmission of the pig lens: effect of ultraviolet A+B radiation. , 2014, Journal francais d'ophtalmologie.

[7]  M. Ayaki,et al.  Surface scattering in implanted hydrophobic intraocular lenses , 2003, Journal of cataract and refractive surgery.

[8]  D. Apple,et al.  Postoperative deposition of calcium on the surfaces of a hydrogel intraocular lens. , 2000, Ophthalmology.

[9]  Ali Akinay,et al.  Measuring ultraviolet-visible light transmission of intraocular lenses: double-beam mode versus integrating-sphere mode , 2012, Journal of biomedical optics.

[10]  Liliana Werner,et al.  Glistenings and surface light scattering in intraocular lenses , 2010, Journal of cataract and refractive surgery.

[11]  T. Senoo,et al.  Analysis of surface whitening of extracted hydrophobic acrylic intraocular lenses , 2009, Journal of cataract and refractive surgery.

[12]  L. Werner,et al.  Light transmittance of 1‐piece hydrophobic acrylic intraocular lenses with surface light scattering removed from cadaver eyes , 2014, Journal of cataract and refractive surgery.

[13]  D. Apple,et al.  Dense opacification of the optical component of a hydrophilic acrylic intraocular lens: A clinicopathological analysis of 9 explanted lenses , 2001, Journal of cataract and refractive surgery.

[14]  A. Felipe,et al.  Ultraviolet radiation at Mediterranean latitudes and protection efficacy of intraocular lenses. , 2013, Journal francais d'ophtalmologie.

[15]  A. Felipe,et al.  Spectral transmission of the human crystalline lens in adult and elderly persons: color and total transmission of visible light. , 2012, Investigative ophthalmology & visual science.

[16]  L. Werner,et al.  Light scattering and light transmittance in intraocular lenses explanted because of optic opacification , 2012, Journal of cataract and refractive surgery.