Pollutant monitoring with fibre optics in the deep ultraviolet

This thesis reports on work carried out in the development of ultraviolet fibre-optic based absorption sensor systems, including those with the newly available ultraviolet improved silica fibres having low attenuation in the 200 nm to 250 nm wavelength region. Several approaches to optimize the optical design of such sensor systems, their sensitivity and stability are discussed. These fibre-optic sensor systems may be used for remote on-line and real-time analysis of process and water quality, enabling a separation of monitoring equipment from the sensor cell, which thus may be situated in a potentially hazardous environment. The effect of temperature variations on wavelength stability and dark output of inexpensive spectrometer modules, potentially useful for field applications, and the subsequent effect on the accuracy of absorption measurements, as well as the sensitivity of such spectrometer modules at wavelength below 250 nm, is investigated. Further, the performance of a remote fibre-optic sensor system, based on a reflectance cell with an optical pathlength of 1 cm, to measure nitrate concentrations in the wavelength region between 200 nm and 250 nm, is reported. Finally, to improve the sensitivity of such ultraviolet sensor systems, the performance of two fibre-coupled sensor cells with increased optical pathlengths has been investigated. The first sensor cell, based on an aluminium coated fused silica capillary cell, having an optical pathlength of 43 em, is demonstrated in the construction of a residual chlorine sensor. The second sensor cell, a capillary cell with an inner coating of Teflon AF, uses the low refractive index and the high transparency of Teflon AF in the ultraviolet to form a liquid-core waveguide (LeW). This sensor cell has an optical pathlength of 203 mm, extending the use of long pathlength cells to the 200 nm to 250 nm wavelength region. Its performance is illustrated when applied to monitoring low concentrations of nitrates, chlorine and acetylsalicylic acid.

[1]  Waveguide Capillary Cell for Low-Refractive-Index Liquids , 1997 .

[2]  C. Childs Low-Pressure Mercury Arc for Ultraviolet Calibration , 1962 .

[3]  Hilmar Franke,et al.  Ultrasensitive detection system for fiber optic-based ultraviolet spectroscopy , 1998, Photonics West - Biomedical Optics.

[4]  Dermot Diamond,et al.  Comparison of the analytical capabilities of an amperometric and an optical sensor for the determination of nitrate in river and well water , 1994 .

[5]  Hsin-Fu Tseng,et al.  Evolution of the solid-state image sensor , 1985 .

[6]  K. Fuwa,et al.  Colorimetry with a total-reflection long capillary cell , 1984 .

[7]  Purnendu K. Dasgupta,et al.  High-Sensitivity Gas Sensors Based on Gas-Permeable Liquid Core Waveguides and Long-Path Absorbance Detection , 1998 .

[8]  Bo Karlberg,et al.  Determination of nitrate in municipal waste water by UV spectroscopy , 1995 .

[9]  K. Fuwa,et al.  Determination of phosphorus in natural waters by long-capillary-cell absorption spectrometry , 1983 .

[10]  H Franke,et al.  Water-core waveguide for pollution measurements in the deep ultraviolet. , 1998, Applied optics.

[11]  G. Naletto,et al.  Performances of metachrome II as a scintillator for the far and vacuum ultraviolet spectral region , 1996 .

[12]  Jay H. Lowry,et al.  Optical characteristics of Teflon AF fluoroplastic materials , 1992 .

[13]  Akira Nomura,et al.  The Use of Poly(Tetrafluoroethylene-Co-Hexafluoropropylene) Tubing as a Waveguide Capillary Cell for Liquid Absorption Spectrometry , 1990 .

[14]  P. Dasgupta Multipath cells for extending dynamic range of optical absorbance measurements , 1984 .

[15]  Kenneth T. V. Grattan,et al.  Smart-sensor approach for a fibre-optic-based residual chlorine monitor , 1997 .

[16]  R. Hoather,et al.  Oxidised nitrogen in waters and sewage effluents observed by ultra-violet spectrophotometry , 1959 .

[17]  Lloyd W. Burgess Absorption-based sensors☆ , 1995 .

[18]  Guido Torelli,et al.  A photosensor array for spectrophotometry , 1995 .

[19]  Kenneth T. V. Grattan,et al.  Binary encoded 2nd-differential spectrometry using UV-Vis spectral data and neural networks in the estimation of species type and concentration , 1997 .

[20]  Mostafa A. El-Sayed,et al.  Application of Liquid Waveguide to Raman Spectroscopy in Aqueous Solution , 1998 .

[21]  J. Fleming,et al.  Refractive index dispersion and related properties in fluorine doped silica. , 1983, Applied optics.

[22]  Stephen D. Scopatz,et al.  Calibrating A Detector Array Based Spectroradiometer With Sub-Pixel Precision , 1989, Photonics West - Lasers and Applications in Science and Engineering.

[23]  Kenneth T. V. Grattan,et al.  Physical analysis of teflon coated capillary waveguides , 1998 .

[24]  Karl-Friedrich Klein,et al.  Stability and lifetime improvements of UV fibers for new applications , 1998, Photonics West - Biomedical Optics.

[25]  Paul J. Gemperline,et al.  Wavelength Calibration Method for a CCD Detector and Multichannel Fiber-Optic Probes , 1995 .

[26]  P. Huibers Models for the wavelength dependence of the index of refraction of water. , 1997, Applied optics.

[27]  Franklin Ormaza-González,et al.  The measurement of nitrite, nitrate and phosphate with test kits and standard procedures: A comparison , 1994 .

[28]  H. Franke,et al.  Increasing the accuracy of liquid analysis and pH-value control using a liquid-core waveguide , 1997 .

[29]  Kenneth T. V. Grattan,et al.  Design and implementation of a fibre-optic-based residual chlorine monitor , 1993 .

[30]  D. Sadler,et al.  Improvements in Spectral Line Shape Reproduction from Spectrographs with CCD Detection , 1996 .

[31]  G. M. Yee,et al.  Miniature spectrometers for biochemical analysis , 1997 .

[32]  C J Sansonetti,et al.  Wavelengths of spectral lines in mercury pencil lamps. , 1996, Applied optics.

[33]  F. Armstrong Determination of Nitrate in Water Ultraviolet Spectrophotometry. , 1963 .

[34]  D. Considine,et al.  Van Nostrand Reinhold encyclopedia of chemistry , 1984 .

[35]  Robert D. Waterbury,et al.  Determination of nanomolar concentrations of nitrite and nitrate in natural waters using long path length absorbance spectroscopy , 1998 .

[36]  R. Byrne,et al.  Long pathlength absorbance spectroscopy: trace analysis of Fe(II) using a 4.5m liquid core waveguide , 1997 .

[37]  M. Munemori,et al.  Continuous flow determination of free chlorine in water , 1983 .

[38]  Charles K. Mann,et al.  Wavelength Calibration of a Multichannel Spectrometer , 1993 .

[39]  J. Norris Multimode optical fiber chemical sensors , 1995 .

[40]  K. Clive Thompson,et al.  Automatic continuous-flow determination of nitrate in raw and potable waters, rivers and sewage effluents by ultraviolet absorption spectrometry , 1984 .

[41]  N. Croitoru,et al.  Plastic hollow fibers as a selective infrared radiation transmitting medium , 1992 .

[42]  Scott D. Schwab,et al.  Remote, Long-Pathlength Cell for High-Sensitivity Raman Spectroscopy , 1987 .

[43]  D. Lynch,et al.  Handbook of Optical Constants of Solids , 1985 .

[44]  G. Locascio,et al.  Ultraviolet–visible photodiode array spectrophotometer wavelength calibration method. A practical computer algorithm , 1991 .

[45]  K. L. Uglum,et al.  Direct spectrophotometric simultaneous determination of nitrite and nitrate in the ultraviolet , 1970 .

[46]  Kenneth T. V. Grattan,et al.  Electrical pH control in aqueous solutions , 1999, Other Conferences.

[47]  H. Franke,et al.  A cylindrical liquid-core waveguide , 1996 .

[48]  A. Rogalski,et al.  Semiconductor ultraviolet photodetectors , 1996 .

[49]  S. Rice,et al.  The design of optical spectrometers , 1969 .

[50]  Véronique Bellón,et al.  Feasibility and Performances of a New, Multiplexed, Fast and Low-Cost Fiber-Optic NIR Spectrometer for the On-Line Measurement of Sugar in Fruits , 1993 .

[51]  W. Rudolf Seitz,et al.  Chemical Sensors Based on Fiber Optics , 1984 .

[52]  Wei Wang,et al.  Absorbance study of liquid-core optical fibers in spectrophotometry , 1992 .

[53]  R. Kuroda,et al.  Direct simultaneous determination of nitrate and nitrite by ultraviolet second-derivative spectrophotometry , 1987 .