In vivo intramuscular fascicle-aponeuroses dynamics of the human medial gastrocnemius during plantarflexion and dorsiflexion of the foot.

Velocity-encoded phase-contrast magnetic resonance (MR) imaging techniques and a computer-controlled MR-compatible foot pedal device were used to investigate the medial gastrocnemius muscle and aponeurosis deformations during passive and active eccentric movements of the plantarflexors. Intrafascicular strain, measured as the ratio of strain in the fascicle segment at its insertion to strain at its origin, was nonuniform along the proximodistal axis of the muscle (P < 0.01), progressively increasing from the proximal to distal direction. The high intrafascicular strain regions appeared to correlate with the muscle regions that are likely to encounter high stress concentrations, i.e., the regions where the muscle physiological cross section decreases close to the tendons. The architectural gear ratio, i.e., the mechanical amplification ratio of fascicle length displacement to that of tendon/aponeuroses in a pennate muscle, also exhibited significant regional differences, with the highest ratios in the proximal region of the muscle accompanied by a higher initial pennation angle and a larger range of fascicular rotation about the origin. Values close to unity in the distal region of the muscle suggest that the aponeurosis separation may decrease in this region. Fascicle length and pennation angle changes were significantly influenced by force generation in the muscle, probably due to a shortening of the loaded muscle fibers relative to a passive condition. Overall, our data illustrate significant proximodistal intramuscular heterogeneity as supported by a regionally variable end-to-end strain ratio of fascicles and angle changes in the medial gastrocnemius muscle during passive and active ankle movements. These observations emphasize the need to reassess current conceptual models of muscle-tendon mechanics.

[1]  J. Fridén,et al.  In vivo measurement of human wrist extensor muscle sarcomere length changes. , 1994, Journal of neurophysiology.

[2]  T. Roberts,et al.  Variable gearing in pennate muscles , 2008, Proceedings of the National Academy of Sciences.

[3]  E. Azizi,et al.  Architectural gear ratio and muscle fiber strain homogeneity in segmented musculature. , 2007, Journal of experimental zoology. Part A, Ecological genetics and physiology.

[4]  V. Edgerton,et al.  Phase-contrast MRI reveals mechanical behavior of superficial and deep aponeuroses in human medial gastrocnemius during isometric contraction. , 2008, Journal of applied physiology.

[5]  C. Maganaris,et al.  In vivo measurements of the triceps surae complex architecture in man: implications for muscle function , 1998, The Journal of physiology.

[6]  M. Narici,et al.  Human skeletal muscle architecture studied in vivo by non-invasive imaging techniques: functional significance and applications. , 1999, Journal of electromyography and kinesiology : official journal of the International Society of Electrophysiological Kinesiology.

[7]  N J Pelc,et al.  Tracking the motion of skeletal muscle with velocity‐encoded MR imaging , 1994, Journal of magnetic resonance imaging : JMRI.

[8]  V. Edgerton,et al.  Effect of chronic unloading and rehabilitation on human Achilles tendon properties: a velocity-encoded phase-contrast MRI study. , 2008, Journal of applied physiology.

[9]  P A Huijing,et al.  Effects of distribution of muscle fiber length on active length‐force characteristics of rat gastrocnemius medialis , 1994, The Anatomical record.

[10]  M Solomonow,et al.  The effect of tendon on muscle force in dynamic isometric contractions: a simulation study. , 1995, Journal of biomechanics.

[11]  S. Delp,et al.  A 3D model of muscle reveals the causes of nonuniform strains in the biceps brachii. , 2005, Journal of biomechanics.

[12]  Usha Sinha,et al.  In vivo diffusion tensor imaging of the human calf muscle , 2006, Journal of magnetic resonance imaging : JMRI.

[13]  Influence of structure on the tissue dynamics of the human soleus muscle observed in MRI studies during isometric contractions , 2006, Journal of morphology.

[14]  A. Anderson,et al.  Validation of diffusion tensor MRI‐based muscle fiber tracking , 2002, Magnetic resonance in medicine.

[15]  Taija Finni,et al.  In vivo estimation and repeatability of force–length relationship and stiffness of the human achilles tendon using phase contrast MRI , 2008, Journal of magnetic resonance imaging : JMRI.

[16]  C. Gans Fiber architecture and muscle function. , 1982, Exercise and sport sciences reviews.

[17]  N. McKee,et al.  Comparing human skeletal muscle architectural parameters of cadavers with in vivo ultrasonographic measurements , 2001, Journal of anatomy.

[18]  V. Edgerton,et al.  Nonuniform strain of human soleus aponeurosis-tendon complex during submaximal voluntary contractions in vivo. , 2003, Journal of applied physiology.

[19]  F. Zajac,et al.  Nonuniform shortening in the biceps brachii during elbow flexion. , 2002, Journal of applied physiology.

[20]  B. Koopman,et al.  Three-dimensional finite element modeling of skeletal muscle using a two-domain approach: linked fiber-matrix mesh model. , 2001, Journal of biomechanics.

[21]  M R Drost,et al.  Finite element modelling of contracting skeletal muscle. , 2003, Philosophical transactions of the Royal Society of London. Series B, Biological sciences.

[22]  E. Otten Concepts and Models of Functional Architecture in Skeletal Muscle , 1988, Exercise and sport sciences reviews.

[24]  P A Huijing,et al.  Muscle, the motor of movement: properties in function, experiment and modelling. , 1998, Journal of electromyography and kinesiology : official journal of the International Society of Electrophysiological Kinesiology.

[25]  V. Edgerton,et al.  Muscle kinematics during isometric contraction: Development of phase contrast and spin tag techniques to study healthy and atrophied muscles , 2004, Journal of magnetic resonance imaging : JMRI.