Measurement of Quasi-Static 3-D Knee Joint Movement Based on the Registration From CT to US

The measurement of quasi-static 3-D knee joint movement is an important basis for studying the mechanism of knee joint injury. Most of the existing measurement methods make use of computed tomography (CT) and nuclear magnetic resonance (MR) imaging technology and hence have the disadvantages of invasiveness, ionizing radiation, low accuracy, and high cost. To overcome those drawbacks, this article innovatively proposes a 3-D motion measurement system for the knee joint based on the registration of CT images to ultrasound (US) images. More specifically, the lower limbs of a subject were first scanned once to acquire the CT images. A portable handheld device was designed to control a US probe for mechanically scanning the subject’s lower limbs in a linear trajectory. During the movement of the subject’s lower limbs, the US scanning was performed quasi-statically. The acquired US images were then registered to the CT images, and the 3-D motions of the lower limb bones could be recreated with the bones scanned in CT images. To guarantee the registration accuracy and efficiency, we used the H-shaped multiview slice assembly as the structural image content for the registration process. The experimental results show that our approach can accurately measure the 3-D motion of the knee joint and meet the needs of 3-D motion analysis of knee joint in practice.

[1]  Johan H. C. Reiber,et al.  The use of Roentgen stereophotogrammetry to study micromotion of orthopaedic implants , 2002 .

[2]  M S Hefzy,et al.  Kinematics of the knee joint in deep flexion: a radiographic assessment. , 1998, Medical engineering & physics.

[3]  Mingxin Zheng,et al.  Long-Duration Tracking of Cervical-Spine Kinematics With Ultrasound , 2019, IEEE Transactions on Ultrasonics, Ferroelectrics, and Frequency Control.

[4]  A. J. van den Bogert,et al.  Effect of skin movement on the analysis of skeletal knee joint motion during running. , 1997, Journal of biomechanics.

[5]  Mark R. Pickering,et al.  Precision analysis of a multi-slice ultrasound sensor for non-invasive 3D kinematic analysis of knee joints , 2012, 2012 Annual International Conference of the IEEE Engineering in Medicine and Biology Society.

[6]  Chedsada Chinrungrueng,et al.  Reconstruction of 3D ultrasound images based on Cyclic Regularized Savitzky-Golay filters. , 2011, Ultrasonics.

[7]  Dan K Ramsey,et al.  Effect of skin movement artifact on knee kinematics during gait and cutting motions measured in vivo. , 2005, Gait & posture.

[8]  Xuelong Li,et al.  Robotic Arm Based Automatic Ultrasound Scanning for Three-Dimensional Imaging , 2019, IEEE Transactions on Industrial Informatics.

[9]  G Selvik,et al.  Roentgen Stereophotogrammetric Analysis , 1990, Acta radiologica.

[10]  Lianwen Jin,et al.  Real-time extended-field-of-view ultrasound based on a standard PC , 2012 .

[11]  Q H Huang,et al.  Development of a portable 3D ultrasound imaging system for musculoskeletal tissues. , 2005, Ultrasonics.

[12]  Xuelong Li,et al.  Bezier Interpolation for 3-D Freehand Ultrasound , 2015, IEEE Transactions on Human-Machine Systems.

[13]  Henry Wong,et al.  Analyzing CUDA workloads using a detailed GPU simulator , 2009, 2009 IEEE International Symposium on Performance Analysis of Systems and Software.

[14]  Qinghua Huang,et al.  Fully Automatic Three-Dimensional Ultrasound Imaging Based on Conventional B-Scan , 2018, IEEE Transactions on Biomedical Circuits and Systems.

[15]  T. Hewett,et al.  Optimization of the anterior cruciate ligament injury prevention paradigm: novel feedback techniques to enhance motor learning and reduce injury risk. , 2015, The Journal of orthopaedic and sports physical therapy.

[16]  Xuelong Li,et al.  Scoliotic Imaging With a Novel Double-Sweep 2.5-Dimensional Extended Field-of-View Ultrasound , 2019, IEEE Transactions on Ultrasonics, Ferroelectrics, and Frequency Control.

[17]  P. Fourie,et al.  The particle swarm optimization algorithm in size and shape optimization , 2002 .

[18]  Xuelong Li,et al.  Automatic ultrasound scanning system based on robotic arm , 2018, Science China Information Sciences.

[19]  F. Noyes,et al.  Factors used to determine return to unrestricted sports activities after anterior cruciate ligament reconstruction. , 2011, Arthroscopy : the journal of arthroscopic & related surgery : official publication of the Arthroscopy Association of North America and the International Arthroscopy Association.

[20]  L. Arata,et al.  Three‐dimensional A‐mode ultrasound calibration and registration for robotic orthopaedic knee surgery , 2010, The international journal of medical robotics + computer assisted surgery : MRCAS.

[21]  Alberto Leardini,et al.  A model-based method for the reconstruction of total knee replacement kinematics , 1999, IEEE Transactions on Medical Imaging.

[22]  Paul N. Smith,et al.  New registration algorithm for determining 3D knee kinematics using CT and single‐plane fluoroscopy with improved out‐of‐plane translation accuracy , 2010, Journal of orthopaedic research : official publication of the Orthopaedic Research Society.

[23]  Kate E Webster,et al.  Return-to-Sport Outcomes at 2 to 7 Years After Anterior Cruciate Ligament Reconstruction Surgery , 2012, The American journal of sports medicine.

[24]  Benjamin J Fregly,et al.  Theoretical accuracy of model-based shape matching for measuring natural knee kinematics with single-plane fluoroscopy. , 2005, Journal of biomechanical engineering.

[25]  B. Otten,et al.  Novel methods of instruction in ACL injury prevention programs, a systematic review. , 2015, Physical therapy in sport : official journal of the Association of Chartered Physiotherapists in Sports Medicine.

[26]  Ioan Cristian Trelea,et al.  The particle swarm optimization algorithm: convergence analysis and parameter selection , 2003, Inf. Process. Lett..

[27]  S.A. Banks,et al.  Accurate measurement of three-dimensional knee replacement kinematics using single-plane fluoroscopy , 1996, IEEE Transactions on Biomedical Engineering.

[28]  Scott Tashman,et al.  In-vivo measurement of dynamic joint motion using high speed biplane radiography and CT: application to canine ACL deficiency. , 2003, Journal of biomechanical engineering.

[29]  Jean-Philippe Thiran,et al.  Towards Ultrasound Everywhere: A Portable 3D Digital Back-End Capable of Zone and Compound Imaging , 2018, IEEE Transactions on Biomedical Circuits and Systems.

[30]  Chen Siping A beam width aware curvilinear ray tracing method for real-time ultrasound simulation , 2012 .

[31]  R. Phillips,et al.  ii) The accuracy of surgical navigation for orthopaedic surgery , 2007 .

[32]  Joseph J Crisco,et al.  Kinematic differences between optical motion capture and biplanar videoradiography during a jump-cut maneuver. , 2013, Journal of biomechanics.