Research on barker coded excitation method for magneto-acoustic imaging

Abstract Functional imaging method of biological electrical characteristics based on magneto-acoustic effect gives valuable information of tissue in early tumor diagnosis. Common exciting and measuring method is to use single pulse. The imaging quality and the imaging speed are limited by the signal to noise ratio (SNR). In this study, we propose a processing method based on coded excitation and pulse compression to improve SNR of magneto-acoustic imaging. Barker code is widely used in ultrasonic signal processing, which can effectively improve the signal to noise ratio. It is introduced to increase SNR of the magneto-acoustic signal. Simulations on magneto-acoustic signal and pulse compressed signal under Barker coded excitation with a group of bit lengths are computed. Experiments on sample made of pork and graphite slices are done to validate the proposed coded excitation method. The pork sample is imaged to validate this method. SNR is investigated using Barker codes with different bits. The results showed, the SNR of magneto-acoustic signal is improved by the coded excitation. When 13 bit Barker code mode is adopted as the exciting signal, SNR improved by 21.5 dB. For a similar SNR improvement, the processing time of coded excitation method can be shortened by 95.8% compare with single pulse excitation method. In a conclusion, the coded excitation method is effective to improve the magneto-acoustic signal SNR and imaging quality. It also improves the magneto-acoustic imaging speed.

[1]  Yuan Xu,et al.  Difference frequency magneto-acousto-electrical tomography (DF-MAET): application of ultrasound-induced radiation force to imaging electrical current density , 2010, IEEE Transactions on Ultrasonics, Ferroelectrics and Frequency Control.

[2]  Melvin J. Hinich,et al.  A Model for a Self-Adapting Filter , 1962, Inf. Control..

[3]  Xiaoqing Zhou,et al.  Magneto-acoustic imaging by continuous-wave excitation , 2016, Medical & Biological Engineering & Computing.

[4]  Gang Wei,et al.  Barker coded excitation with linear frequency modulated carrier for ultrasonic imaging , 2014, Biomed. Signal Process. Control..

[5]  Amin Arbabian,et al.  Frequency-Modulated Magneto-Acoustic Detection and Imaging: Challenges, Experimental Procedures, and B-Scan Images , 2014 .

[6]  Bin He,et al.  Magnetoacoustic tomography with magnetic induction (MAT-MI) for imaging electrical conductivity of biological tissue: a tutorial review , 2016, Physics in medicine and biology.

[7]  W N McDicken,et al.  Adaptive time gain compensation for ultrasonic imaging. , 1992, Ultrasound in medicine & biology.

[8]  Takao Jibiki [Coded excitation medical ultrasound imaging] , 2001, Igaku butsuri : Nihon Igaku Butsuri Gakkai kikanshi = Japanese journal of medical physics : an official journal of Japan Society of Medical Physics.

[9]  H. Curtis,et al.  ELECTRIC IMPEDANCE OF THE SQUID GIANT AXON DURING ACTIVITY , 1939, The Journal of general physiology.

[10]  Bradley J Roth,et al.  The role of magnetic forces in biology and medicine , 2011, Experimental biology and medicine.

[11]  Di Li,et al.  CORRIGENDUM: The work mechanism and sub-bandgap-voltage electroluminescence in inverted quantum dot light-emitting diodes , 2015, Scientific Reports.

[12]  Bin He,et al.  Magnetoacoustic tomographic imaging of electrical impedance with magnetic induction. , 2007, Applied physics letters.

[13]  August W. Rihaczek,et al.  Range Sidelobe Suppression for Barker Codes , 1971, IEEE Transactions on Aerospace and Electronic Systems.

[14]  Cui Lian-hua A Quai-CW Radar Waveform Design Based on Multimode Arbitrary Code Sequence to Avoid Echo Eclipse , 2013 .

[15]  M.R. Islam,et al.  A magneto-acoustic method for the noninvasive measurement of bioelectric currents , 1988, IEEE Transactions on Biomedical Engineering.

[16]  Dieter Haemmerich,et al.  Electrical conductivity measurement of excised human metastatic liver tumours before and after thermal ablation , 2009, Physiological measurement.

[17]  Dong C. Liu,et al.  Enhanced ultrasound strain imaging using chirp-coded pulse excitation , 2013, Biomed. Signal Process. Control..

[18]  Xu Li,et al.  B-Scan Based Acoustic Source Reconstruction for Magnetoacoustic Tomography With Magnetic Induction (MAT-MI) , 2011, IEEE Transactions on Biomedical Engineering.

[19]  J. Shah,et al.  Hall effect imaging , 1998, IEEE Transactions on Biomedical Engineering.

[20]  B.A. Baertlein,et al.  Authors' reply [to comments on "Theoretical model for an MRI radio frequency resonator"] , 1994, IEEE Transactions on Biomedical Engineering.

[21]  Bin He,et al.  Magnetoacoustic tomography with magnetic induction (MAT-MI) , 2005, Physics in medicine and biology.

[22]  Yuanjin Zheng,et al.  Coexisting and mixing phenomena of thermoacoustic and magnetoacoustic waves in water , 2015, Scientific reports.

[23]  Jong Seob Jeong,et al.  Electromagnetic acoustic imaging , 2013, IEEE Transactions on Ultrasonics, Ferroelectrics and Frequency Control.

[24]  Tao Yin,et al.  A study on locating the sonic source of sinusoidal magneto-acoustic signals using a vector method. , 2015, Bio-medical materials and engineering.

[25]  Pierfrancesco Lombardo,et al.  WiFi-Based Passive Bistatic Radar: Data Processing Schemes and Experimental Results , 2012, IEEE Transactions on Aerospace and Electronic Systems.

[26]  M. Rangaswamy,et al.  Phase-Coded Waveforms and Their Design , 2009, IEEE Signal Processing Magazine.

[27]  Stuchly,et al.  Dielectric properties of breast carcinoma and the surrounding tissues , 1988, IEEE Transactions on Biomedical Engineering.

[28]  R. W. Lau,et al.  The dielectric properties of biological tissues: II. Measurements in the frequency range 10 Hz to 20 GHz. , 1996, Physics in medicine and biology.

[29]  Bin He,et al.  Magnetoacoustic tomography with magnetic induction for high-resolution bioimepedance imaging through vector source reconstruction under the static field of MRI magnet. , 2014, Medical physics.