Investigation on Seismic Performance of Bidirectional Self-Centering Reinforced Concrete Frame Structures by Shaking Table Tests

This paper presents an experimental study on the seismic performance of a bidirectional self-centering reinforced concrete (RC) frame structure. In the structure, the column-base joints, which were installed with external mild steel (MS) dampers, could uplift freely and the beam-column joints could open effectively under earthquake excitations. Angle steels and MS dampers were installed at the beam-column joints in the structural X and Y directions, respectively. During the gap opening of the joints, unbonded posttensioned (PT) steel wires, which passed through the plastic ducts inserted in the RC beams and columns, provided the structure with the ability to return to pre-earthquake positions, and the yielding MS dampers and angle steels dissipated the seismic energy. A 1/2-scale two-story model structure was designed and constructed. Shaking table tests were performed on the structure under four different types of earthquake excitations with increasing seismic hazard levels. The test results indicated that the self-centering RC frames installed in both the directions showed satisfactory seismic performance, with only slight damage to the main structure after extreme earthquakes. The natural frequencies of the self-centering frames installed in both the directions degraded progressively, mainly because of the prestress loss of the PT steel wires and the yielding of the MS dampers. The structure showed desirable self-centering ability with very small residual deformation under ground motions of all hazard levels. The structural deformation was mainly concentrated at the column-base and beam-column joints, and hence, damage to the concrete beams and columns was considerably alleviated. In addition, the residual gap opening of the joints was minimal.

[1]  Xxyyzz,et al.  Minimum Design Loads for Buildings and Other Structures , 1990 .

[2]  G. Cheok,et al.  Performance of 1/3-Scale Model Precast Concrete Beam-Column Connections Subjected to Cyclic Inelastic Loads , 1990 .

[3]  H. S. Lew,et al.  Model Precast Concrete Beam-to-Column Connections Subject to Cyclic Loading , 1993 .

[4]  William C. Stone,et al.  Simplified Design Procedure for Hybrid Precast Concrete Connections , 1996 .

[5]  John F. Stanton,et al.  An Overview of the PRESSS Five-Story Precast Test Building , 1999 .

[6]  Sri Sritharan,et al.  Preliminary results and conclusions from the PRESSS five-story precast concrete test Building , 1999 .

[7]  Robert E. Englekirk Design-construction of The Paramount: a 39-story precast prestressed concrete apartment building , 2002 .

[8]  M. J. Priestley,et al.  Direct Displacement-Based Design of Precast/Prestressed Concrete Buildings , 2002 .

[9]  Minehiro Nishiyama,et al.  Seismic Performance of Precast Column-Foundation Connection Assembled by Post-Tensioning , 2003 .

[10]  Brian G. Morgen,et al.  A Friction Damper for Post-Tensioned Precast Concrete Moment Frames , 2004 .

[11]  Sevket Ozden,et al.  Behavior of Unbonded, Post-Tensioned, Precast Concrete Connections with Different Percentages of Mild Steel Reinforcement , 2007 .

[12]  Mervyn J. Kowalsky,et al.  Displacement-based seismic design of structures , 2007 .

[13]  Gongkang Fu,et al.  Shake table model testing and its application , 2008 .

[14]  Alessandro Palermo,et al.  Quasi‐static and pseudo‐dynamic testing of unbonded post‐tensioned rocking bridge piers with external replaceable dissipaters , 2009 .

[15]  Dion James Marriott The Development of High-Performance Post-Tensioned Rocking Systems for the Seismic Design of Structures , 2009 .

[16]  Amaris Mesa,et al.  Developments of Advanced Solutions for Seismic Resisting Precast Concrete Frames , 2010 .

[17]  Stefano Pampanin,et al.  EXPECTATION MEETS REALITY: SEISMIC PERFORMANCE OF POST- TENSIONED PRECAST CONCRETE SOUTHERN CROSS ENDOSCOPY BUILDING DURING THE 22 ND FEB 2011 CHRISTCHURCH EARTHQUAKE , 2011 .

[18]  Tong Guo,et al.  Experimental and numerical study of a self‐centering prestressed concrete moment resisting frame connection with bolted web friction devices , 2014 .

[19]  Ye Cui,et al.  Shaking table test and numerical simulation of a 1/2‐scale self‐centering reinforced concrete frame , 2015 .

[20]  Stefano Pampanin,et al.  Fuse-Type External Replaceable Dissipaters: Experimental Program and Numerical Modeling , 2016 .

[21]  Tong Guo,et al.  Fragility analysis of self-centering prestressed concrete bridge pier with external aluminum dissipators , 2017 .

[22]  Xilin Lu,et al.  Experimental investigation of tri-axial self-centering reinforced concrete frame structures through shaking table tests , 2017 .

[23]  R. Sarpong,et al.  Bio-inspired synthesis of xishacorenes A, B, and C, and a new congener from fuscol† †Electronic supplementary information (ESI) available. See DOI: 10.1039/c9sc02572c , 2019, Chemical science.

[24]  W. Hager,et al.  and s , 2019, Shallow Water Hydraulics.